background image

    Belonging  to

CONFORMITY

Installation and user

guide

Important: Assembly / maintenance of the appliance must be carried out by qualified personnel and in

accordance with applicable laws and regulations.

The manufacturer assumes no responsibility for the use of products that have to comply with particular

environmental and / or installation standards.

Important note

Before connecting the equipment, it is recommended that you read the instruction manual carefully and

keep it for future reference. It is also recommended to perform the electrical connections correctly as

per enclosed drawings, observing the instructions and the Standards.

N.B. Refer to the documentation in all cases where the symbol is on the side

EN 50194

EN 50270

Compliant  EN 60079-29-1

Installation  EN 60079-29-2

Reports issued by  TUV Italia

Channel:  Beinat  gas  solutions

Electric connections also available on

Conventional Gas Sensor SG544

V. 3

The SG544is born from the elegance and prestige that has always distinguished  BEINAT S.r.l. and from the

home fitness concept.

The  probe is a Catalytic gas detection unit with IP44 protection that, together with one of BEINAT’s industrial

type Control Units, detects the presence of esplosive gas such as Methane, LPG.

The sensor provides a signal of alarm to the control unit to which it is connected with a sensitivity of intervention

calibrated within 20% of the LEL.

The  degree  of  protection  that  is  provided  allows  the  useeven  in  critical  conditions  of  moisture,  dusty

environments and where the norms require, making it ideal for its use in industrial environments.

The probe has a linear output 0 to 20% LEL, working with the standard 4 to 20 mA.

Содержание SG544

Страница 1: ...0 Compliant EN 60079 29 1 Installation EN 60079 29 2 Reports issued by TUV Italia Channel Beinat gas solutions Electric connections also available on Conventional Gas Sensor SG544 V 3 The SG544is born from the elegance and prestige that has always distinguished BEINAT S r l and from the home fitness concept The probe is a Catalytic gas detection unit with IP44 protection that together with one of ...

Страница 2: ... 110 mA max 13 8V Sensor Catalytic Sensor range of measurement 0 100 of L E L Detector range of measurement 0 20 of L E L Detection Gas Methane LPG Output 4mA 20mA standard tolerance Accuracy 1 Long term shift in clean air 3 LELWarm up time 1 5 minutes Control units that can be used BX444 Mc BX449F GS100M BX280 BX180 GS300 Mc BX316xp BX308xp Functioning Humidity 0 90 non condensed Functioning Temp...

Страница 3: ... unit 1 zone Omega bar DIN 2 IP20 1 1 YES NO BX449F unit 1 zone Omega bar DIN 4 IP20 1 1 YES NO BX308xp unit 1 zone Omega bar DIN 8 IP20 1 1 YES YES BX308xp Box unit 1 zone Wall 8 IP65 1 1 YES YES BX316xp unit 2 zones Barra Omega 16 IP20 1 2 YES YES BX316xp Box unit 2 zones Wall 16 IP65 1 2 YES YES Opening of the Cover With the help of a screwdriver to turn counterclockwise for a quarter of turn C...

Страница 4: ...nt of the ceiling in order to detect light gases Methane etc The probe should not be placed near the appliances to be controlled boilers burners industrial kitchens etc but on the opposite wall The probe should not be affected by smoke vapour etc as they could distort their measurement It must be placed away from sources of heat suction fans ventilation fans 30 cm Light Gases 30 cm Heavy Gases Pos...

Страница 5: ...voltage is correct Carefully follow the instructions and the connections according to Regulations in force keeping in mind that the signal cables should be laid separate from the power cables Electricalconnections R 1 2 3 Power Supply 12 24 V Linear Output 4 20 mA ...

Страница 6: ...r the Distributor of BEINAT S r l should be contacted directly The installation of the SG544 probe its ordinary and extraordinary maintenance and its out of service removal at the end of the functional life guaranteed by the manufacturer must be carried out by authorized or specialized personnel The general test should be performed by issuing gas from a pre calibrated aerosol According to the EN 6...

Страница 7: ...consequent measures taken If the alarm continues and the cause of gas presence cannot be found or removed abandon the building and call the emergency services when outside fire department distributors etc IMPORTANT The operation test should not be carried out with the gas tap as this does not guarantee a sufficient concentration to activate the general alarm Warning If you have the following sympt...

Страница 8: ... its enforced suspension of use DISPOSAL OF OLD ELECTRICAL ELECTRONIC EQUIPMENT This symbol on the product or its packaging to indicates that this product shall not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment such as for example sales points in case you buy a new and similar product local ...

Отзывы: