background image

Page  3

Gas  detection  function
Press  the  button  to  turn  on  or  turn  off  the  instrument,  press  and  hold  for  5  seconds.

Explosive GAS detection
When you turn on the appliance you will see a         COUNT DOWN starts on the display lasting about 30 seconds (pre-
heating). When complete, the instrument is ready for use.

 Hold the detector in your hand at an average height from the ground to detect any gas dispersed in air or bring
the tip of the flexible antenna near the probable sources of leak which:
-Pipes
-Couplings
-Joints
-Electro  valves
-Nicches

If the instrument detects a leak, the percentage of LEL GAS appears on the display, along with an intermittent
sound that is more or less frequent depending on the amount detected. Together with the sound, the display
lights color red.

Backlight
Pressing the button turns on the backlight in green color with a duration of 5 seconds.

Display of the battery charge status
The display shows the battery symbol.
When the battery is charged the symbol is all black, discharging becomes white, when it flashes is discharged

Note: The unit will have an auto shut off after 10 minutes of inactivity (no button pressure and no gas detection).

If the appliance does not turn on.
Check the battery is charged. If not, charge or replace it.
Note: With low battery, gas measurement might not be reliable.

Gas is not being detected.
Check that the capsule is working. If burnt, “FAU” appears on the display.
In the event other problems arise, directly contact a specialist and/or authorised technician or your BEINAT S.r.l.
dealer
.

Gas detection function Components and commands

NASE25

100

LEL

 

 

 

 

 

 

0

 

Gas Detection Display

20

LEL

FAU

 

 

 

 

 

 0

The  di spl ay  wi th  neutral   col or
shows  an  absence  of  leakage  of
gas.
Backlight  off

Normal  state

Normal  state

Alarm  state

Alarm  state

The  display  with  yellow
color  and  the  sign  FAU
shows  a  probes’s  fault.

The  display  with  green  color
shows  an  absence  of  leakage
of  gas.
Backlight  on
Press  the  button

The  illuminated  red  flashing  LED
indicates  gas  presence,  whose
concentration  is  expressed  in
L EL .
As  the  LEL  increases,  acoustic
signal  increases  its  frequency.

Содержание NASE25

Страница 1: ...y it the common people turn to technicians who need to be assured that their work is free of dangers To do this we need a reliable and secure control tool With its prestige that for over forty years distinguishes it and from the concept of Fitness equipment BEINAT S r l has developed the portable gas detector NASE25 Explosive Gas Detection The modernity of this instrument and its precision in the ...

Страница 2: ...ore disclaims any responsibility for possible damages caused to people animals or objects Do not allow it to become wet The detector can be seriously damaged as it is not waterproof either when immersed in water or exposed to high levels of humidity Do not drop it Heavy knocks on hard surfaces and strong vibrations can damage the appliance Avoid strongmagnetic fields This detector should not be us...

Страница 3: ...en the battery is charged the symbol is all black discharging becomes white when it flashes is discharged Note The unit will have an auto shut off after 10 minutes of inactivity no button pressure and no gas detection If the appliance does not turn on Check the battery is charged If not charge or replace it Note With low battery gas measurement might not be reliable Gas is not being detected Check...

Страница 4: ...ble damage direct or indirect to people animals or things from product faults and from its enforced suspension of use DISPOSAL OF OLD ELECTRICAL ELECTRONIC EQUIPMENT This symbol on the product or its packaging to indicates that this product shall not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equip...

Отзывы: