5.1.6.2 Settings of Warn Voltage (Alarm)
1) Setting first alarm level and second alarm level value. First alarm level is
recommended as 44.4V~45V, second alarm level is recommended as 43.8V~44.4V.
The default first alarm is 44.4V,the second alarm is 43.8V
2) LED will flash in yellow in three times in first alarm level inspected by flight controller.
3) LED will flash in yellow quickly and low voltage protection will be triggered in second
alarm level.Returning,landing or flash will be executed according to settings of
customer.
5.1.6.3 Settings of Voltage Calibration
Flight controller voltage sensor need to be calibrated if flight controller voltage sensor
result is different from real voltage.Real battery voltage should be filled in measured
voltage,flight controller voltage will be calibrated by clicking save.
It’s unnecessary to set
by user as calibration has been done before delivery.
5.1.7 Agriculture Function
5.1.7.1 One key to Lateral Moving
1) Interaction:pump is controlled interacted,maximum water flow correspond to
maximum flying speed.
Factory default value: max:6m /s, minimum: 0.2m/s .