background image

Mechanical

Connector Pinouts

 QTERM-A12 Terminal

31

7.2.5

USB 2.0 Ports

The QTERM-A12 includes two USB 2.0 full-speed ports. The connector orientation and 
pinout table are shown below.

C

AUTION

For Class I, Division 2 installations:
The USB ports are for operational maintenance only. Do not leave USB devices permanently 
connected unless the area is known to be non-hazardous.

C

AUTION

For Class I, Division 2 installations:
Do not connect or disconnect cables while power is applied unless the area is known to be 
non-hazardous.

Pinout Table

 Figure 17

USB Connector

1

VCC (+5 VDC)

2

Data -

3

Data  +

4

Ground

Содержание QTERM-A12

Страница 1: ...RDWARE MANUAL BEIJER ELECTRONICS 2212 South West Temple 50 Salt Lake City Utah 84115 2648 USA Phone 801 466 8770 Fax 801 466 8792 Email info beijerelectronicsinc com Web http www beijerelectronicsinc...

Страница 2: ...rity and QTERM are registered trademarks of Beijer Electronics Microsoft Windows Windows NT Windows 2000 Windows XP Vista ActiveSync and their respective logos are registered trademarks of Microsoft C...

Страница 3: ...quipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation...

Страница 4: ...Notes...

Страница 5: ...Memory 9 4 4 Serial Communications 10 4 5 Network 10 4 6 Speaker 10 4 7 Power Supply 11 4 8 Housing 11 CHAPTER 5 INSTALLATION 13 5 1 Cutting Out for Panel Mount 14 5 1 1 Standard Version Cutout 14 5 1...

Страница 6: ...Contents ii QTERM A12 Terminal Notes...

Страница 7: ...28 Mbytes of DDR SDRAM Two USB 2 0 full speed host ports with built in support for standard USB keyboards mice and memory devices 10 100Base T wired Ethernet Two serial ports one EIA 232 422 485 softw...

Страница 8: ...Introduction 2 QTERM A12 Terminal Notes...

Страница 9: ...nt may be impaired Do not use the QTERM A12 to directly command motors valves or other actuators not equipped with safeguards To do so can be potentially harmful to persons or equipment in the event o...

Страница 10: ...Safety Summary 4 QTERM A12 Terminal Notes...

Страница 11: ...of the chassis ground terminal and the 3 pin power terminal strip The terminal should be connected to earth ground protective earth The chassis ground is not con nected to signal common of the termin...

Страница 12: ...nal strip provides a chassis ground connection The chassis ground pin is isolated from the sys tem ground of the terminal WARNING Although the terminal includes protection circuitry to prevent power...

Страница 13: ...ll included features will be operational In this mode the terminal will complete 2 event classifi cation as specified by IEEE 802 3at 2009 and operate as a Type 2 Class 4 PoE Powered Device PD The QTE...

Страница 14: ...Powering On the Terminal for the First Time When you connect power to the QTERM A12 terminal the operating system is automatically loaded The QTERM A12 takes 10 to 20 seconds to boot During that time...

Страница 15: ...be used to add many other devices such as a keyboard mouse or additional mass storage Adding USB peripherals that are not self powered will increase the power consumption of the termi nal 4 2 Process...

Страница 16: ...rk The QTERM A12 has an internal 10 100Base T wired Ethernet adapter for network commu nications The network interface is accessed through a standard RJ45 socket located on the back of the unit 4 6 Sp...

Страница 17: ...is ground isolated from the system Alternatively power may be applied through pin 9 of the COM1 DB9 In this case pin 5 is the power ground return If equipped with optional Power over Ethernet PoE the...

Страница 18: ...Housing Hardware Description and Architecture 12 QTERM A12 Terminal Notes...

Страница 19: ...the panel The modular version of the QTERM A12 does NOT have a factory installed front bezel The modular version of the terminal is ideal for installations that require a custom front bezel or no bez...

Страница 20: ...ectangular hole in the panel using the following dimensions NOTE See the QTERM A12 Cutout and Mounting Guide insert that was included in the box with the QTERM A12 for installation instructions Printe...

Страница 21: ...Cutout and Mounting Guide insert that was included in the box with the QTERM A12 for installation instructions Printed on the back of the insert is a cutout tem plate that can be used to trace the cut...

Страница 22: ...e printed labels on the back panel may indicate the orientation If not you can deter mine which side should be at the top by the position of the serial port s on the back panel as follows Landscape Wh...

Страница 23: ...7 8 N cm 6 lbs in to create a seal between the terminal gasket and the panel Avoid overtightening the nuts 5 2 2 Modular Version Installation The modular version installation steps are to be used with...

Страница 24: ...front of the unit the back panel serial port s should be facing down Portrait When looking at the front of the unit the back panel serial port s should be facing left Refer to Figure 4 for an example...

Страница 25: ...esistive operation 5 wire construction Anti glare surface treatment with 3H hardness INTERFACE Primary serial port User configurable EIA 232 EIA 422 or EIA 485 interface with selectable 485 AC termina...

Страница 26: ...to 70 C Storage 30 to 85 C Humidity 5 to 95 non condensing Vibration 10 to 1500 Hz 4 g RMS Shock 40 g 11 ms common orthogonal axes Electrical transient and noise As specified in EN55024 ESD 8 kV cont...

Страница 27: ...ting system Microsoft Windows Embedded CE version 6 0 R3 Professional CERTIFICATION FCC Part 15 Class A CE Certification EN 55022 EN 55024 and EN 60950 UL Listed by Und Lab Inc To U S and Canadian saf...

Страница 28: ...Specifications 22 QTERM A12 Terminal Notes...

Страница 29: ...ns 7 1 1 Standard Version The standard version of the QTERM A12 is equipped with a factory installed front bezel The front bezel has molded in studs that are used together with a terminal ring to moun...

Страница 30: ...Layout and Dimensions Mechanical 24 QTERM A12 Terminal Figure 6 QTERM A12 Back View units mm Figure 7 QTERM A12 Bottom View units mm...

Страница 31: ...Mechanical Layout and Dimensions QTERM A12 Terminal 25 Figure 8 QTERM A12 Side View units mm...

Страница 32: ...A12 does NOT have a front bezel Mounting studs must be integral to the panel where the QTERM A12 will be mounted The modular version allows installers to use their own custom bezel or to use the pane...

Страница 33: ...Mechanical Layout and Dimensions QTERM A12 Terminal 27 Figure 11 Modular QTERM A12 Bottom View units mm Figure 12 Modular QTERM A12 Side View units mm...

Страница 34: ...und Ground Ground 6 7 CTS in RX 8 RTS out TX RTX 9 Power In Power In Power In WARNING Although the terminal includes protection circuitry to prevent power supply contention power should not be simulta...

Страница 35: ...a chassis ground connection The chassis ground pin is isolated from the sys tem ground of the terminal CAUTION For Class I Division 2 installations Do not connect or disconnect cables while power is...

Страница 36: ...The connector orientation and pinout table are shown below For PoE pinout infor mation please refer to section 3 4 Optional Power over Ethernet Interface CAUTION For Class I Division 2 installations D...

Страница 37: ...lass I Division 2 installations The USB ports are for operational maintenance only Do not leave USB devices permanently connected unless the area is known to be non hazardous CAUTION For Class I Divis...

Страница 38: ...Connector Pinouts Mechanical 32 QTERM A12 Terminal Notes...

Отзывы: