The mains connection of the ULTRAMIZER PRO is made by using the supplied cable. It meets all of the

international safety certification requirements. Please make sure that all units have a proper ground connec-

tion.

+

Before you connect your ULTRAMIZER PRO to the mains, please make sure that your local

voltage matches the voltage required by the unit (see chapter 6 “SPECIFICATIONS” for details)!

As a standard the audio inputs and outputs on the BEHRINGER ULTRAMIZER PRO are fully balanced. If

possible, connect the unit to other devices in a balanced configuration to allow for maximum interference

immunity. The automatic servo function detects unbalanced connections and compensates the level difference

automatically (6 dB correction).
The MIDI links (IN/OUT/THRU) are made over standardized DIN patch cords. The data communication is

isolated from ground by an opto-coupler.

1.3

 

Control elements

Fig. 1.1: ULTRAMIZER PRO front panel

The BEHRINGER ULTRAMIZER PRO is equipped with ten illuminated parameter keys, one jog wheel (rotary

control), a numeric display, 8 LED indicators and a power switch. Each of the two fully independent channels

can be monitored with four 8-stage LED meters, displaying input level, output level and gain reduction for both

bands.

1.3.1 Front panel

Fig. 1.2: Display section DSP1424P

1

The two 

LED

 chains read the input signal level in dB, referenced to the internal digital maximum.

+

Please  note  that  the  nominal  level  of  the  ULTRAMIZER PRO  can  be  selected  with  the

+4 dBu / -10 dBV switch located on the back panel (see chapter 3.1).

2

The gain reduction meters show the applied gain reduction. Gain reduction is shown for both frequency

bands. 

GR LO

 shows the gain reduction in the lower and 

GR HI

 in the higher frequency band.

3

These two 

OUT LED

 chains read the output signal level in dB, referenced to the maximum output level

of +15 dBu.

4

After power-up, the 

LED

 display reads the number of the preset last used. This clearly legible, 2½ digit

numeric display has plus/minus indicators to show that parameters are being incremented or decremented

in edit mode.

1. INTRODUCTION

All manuals and user guides at all-guides.com

Содержание ULTRAMIZER PRO DSP1424P

Страница 1: ...Version 1 0 September 2002 User s Manual ENGLISH ULTRAMIZER PRO DSP1424P www behringer com All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 2: ...evices including amplifiers that produce heat Power Source The device should be connected to a power supply only of the type described in the operating instructions or as marked on the device Groundin...

Страница 3: ...INGER family With your highly competent suggestions for new products you ve greatly contributed to shaping our company and making it successful In return we guarantee you uncompromising quality manufa...

Страница 4: ...reates an incredible bass sound below your loudspeaker s frequency range s Incorporated leveler for constant average output level while retaining the instantaneous dynamics s Free ULTRAMIZER software...

Страница 5: ...ULTRAMIZER PRO in analog recording 16 3 2 2 The ULTRAMIZER PRO in digital recording and sampling 16 3 2 3 The ULTRAMIZER PRO in mastering 16 3 3 The ULTRAMIZER PRO as a protective device 17 3 3 1 Prot...

Страница 6: ...spectrum into two bands prior to performing the dynamic functions This enables a very musical and effective compression of the program material signal On top of that the ULTRAMIZER PRO also features a...

Страница 7: ...RO is equipped with ten illuminated parameter keys one jog wheel rotary control a numeric display 8 LED indicators and a power switch Each of the two fully independent channels can be monitored with f...

Страница 8: ...ight up in the display can be adjusted The subjec tively felt density of the program material is the result of the amount of compression that is applied The DENSITY can be adjusted from 0 no compressi...

Страница 9: ...can be adjusted ranging from 0 to 100 PROC will light up b Pressed a second time the TUNE parameter can be set Hz will light up Here the TUNE control sets the upper cut off frequency of the super bass...

Страница 10: ...selected voltage Please note that depending on the mains voltage supplied to the unit the correct fuse type and rate must be installed see chapter 6 SPECIFICATIONS Please use the enclosed mains cable...

Страница 11: ...ill perform as a brick wall limiter which will affect transients ULTRAMIZERRANGE The parameter RANGE which you access after pressing the ULTRAMIZER key three times determines the maximal gain the Ultr...

Страница 12: ...parameter 2 1 5 The 3D Surround function With the the 3D surround function the ULTRAMIZER PRO can be used as a 3D stereo surround processor increasing the stereo width of the program material Whether...

Страница 13: ...wer right corner of the display After loading the data the ULTRAMIZER PRO enables the preset and the dot disappears This brief interruption avoids the direct activation of every preset as you scroll t...

Страница 14: ...nge setup The display reads a capital P program Here too four modes can be selected with the jog wheel as follows LVSOD 0RGH 0 No program change data are transmitted 1 Program change data are received...

Страница 15: ...MIZER PRO We are currently developing a software editor which will allow for storing single items of the unit s internal data on an external medium Thus it will be possible to archive ULTRAMIZER PRO s...

Страница 16: ...d In extreme cases it will cause distortion due to tape saturation In contrast to analog side effects in the digital field always become extremely audible with decreasing level a tape previously recor...

Страница 17: ...e damaged by an occasional high level overload e g the sound of a microphone falling onto a hard floor In order to protect a system or the loudspeak ers the application of the BEHRINGER ULTRAMIZER PRO...

Страница 18: ...he dynamic functions of the crossover 3 4 The ULTRAMIZER PRO in combination with a multitrack In connection with multi track machines the BEHRINGER ULTRAMIZER PRO can be used to prevent distor tion ca...

Страница 19: ...mit with the highest obtainable average level and use a multiplicity of signal processors to achieve this despite the effects on the quality of the program material If a limiter with active pre emphas...

Страница 20: ...ish to save When the preset is activated its parameters are transmitted as controller data and can be recorded on a sequencer or similar device Repeat this routine until all presets of your choice hav...

Страница 21: ...IMPORTANT This does not apply for general export models which are built for one operating voltage only The AC voltage selection is defined by the position of the fuse holder If you intend to change th...

Страница 22: ...22 ULTRAMIZER PRO DSP1424P Fig 4 1 Different plug types 4 INSTALLATION All manuals and user guides at all guides com...

Страница 23: ...X X Notes O YES X NO Mode 1 OMNI ON POLY Mode 2 OMNI ON MONO Mode 3 OMNI OFF POLY Mode 4 OMNI OFF MONO Tab 5 1 MIDI implementation chart Parameter Name Display Range Midi Controller Number Controller...

Страница 24: ...socket IN OUT THRU Digital processing Converters 24 bit Sigma Delta 64 128 times oversampling Sampling rate 46 875 kHz Display Type 2 digit numeric LED display Power supply Mains Voltages USA Canada...

Страница 25: ...placed within 30 days of receipt of the product at BEHRINGER 2 If the product needs to be modified or adapted in order to comply with applicable technical or safety standards on a national or local le...

Отзывы: