Behringer ULTRAMIZER PRO DSP1424P Скачать руководство пользователя страница 10

10

ULTRAMIZER PRO DSP1424P

     

1.3.2 Back panel

Fig. 1.4: Back panel connectors and control elements

18

Use the 

OPERATING LEVEL

 switch to adapt the ULTRAMIZER PRO to different operating levels. You

can select a -10 dBV semi-pro level used for home recording and a +4 dBu level used in professional

studios. This way the ULTRAMIZER PRO is always optimally adapted to the used nominal operating

level.

19

These are the ULTRAMIZER PRO’s analog

 INPUTS.

 The ULTRAMIZER PRO has both XLR and 1/4"

TRS inputs and outputs. Each XLR and jack set is wired parallel and can be used either balanced or

unbalanced.

20

These are the ULTRAMIZER PRO’s analog 

OUTPUTS

. Also on balanced XLR and 1/4" TRS connectors.

21

SERIAL  NUMBER

.  Please  complete  and  return  the  warranty  card  within  14  days  of  the  date  of

purchase. Otherwise, you will lose your right to the extended warranty. Alternatively, you can register

online at our website under www.behringer.com.

22

These are the ULTRAMIZER PRO’s MIDI connectors (

MIDI OUT / THRU / IN

). Via these connectors

total remote control is possible.

23

This is the 

MAINS CONNECTOR / FUSE HOLDER / VOLTAGE SELECTOR. 

Before you connect the

unit, please make sure that the displayed voltage corresponds to your mains supply. Please note that

the AC voltage selection is defined by the position of the fuse holder. If you intend to change the

operating voltage, remove the fuse holder and turn it by 180 degrees before you reinsert it. Matching the

two markers monitors the selected voltage. Please note that, depending on the mains voltage supplied

to the unit, the correct fuse type and rate must be installed (see chapter 6 “SPECIFICATIONS”). Please

use the enclosed mains cable to connect the unit to the mains power supply.

+

Please note that not all appliances can be used with different mains voltage ratings. Please

check the description on the back of the unit and the box.

1.3.3 Restoring factory defaults

To protect the DSP1424P against user errors, an important edit command has been implemented via a particu-

lar key combination. In normal operating mode the presets cannot be reset to their factory defaults, so as to

secure your own programs as safely as possible. Please proceed as follows to reinitialize the preset default

settings:

+

Press and keep the keys EFFECT and PRESET 

before powering up

 the ULTRAMIZER PRO. Then

switch on the DSP1424P and keep the two keys pressed for about two seconds. The program

numbers are counted up and reset to their original default settings.

2. OPERATION

The ULTRAMIZER PRO is one of the latest generation digital processing devices. Especially designed for

processing the total mix or complex music signals. BEHRINGERs past experience in digital and analog

processing devices come together in this new device. In the DSP1424P, the advantages of digital technology

go hand in hand with the warm and powerful sound of analog devices. The ULTRAMIZER PRO combines

multiple functions for the processing of stereo signals in one device. It is a multi-band compressor, a 3D

surround processor, a denoiser as well as an exciter and a bass processor.

2. OPERATION

All manuals and user guides at all-guides.com

Содержание ULTRAMIZER PRO DSP1424P

Страница 1: ...Version 1 0 September 2002 User s Manual ENGLISH ULTRAMIZER PRO DSP1424P www behringer com All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 2: ...evices including amplifiers that produce heat Power Source The device should be connected to a power supply only of the type described in the operating instructions or as marked on the device Groundin...

Страница 3: ...INGER family With your highly competent suggestions for new products you ve greatly contributed to shaping our company and making it successful In return we guarantee you uncompromising quality manufa...

Страница 4: ...reates an incredible bass sound below your loudspeaker s frequency range s Incorporated leveler for constant average output level while retaining the instantaneous dynamics s Free ULTRAMIZER software...

Страница 5: ...ULTRAMIZER PRO in analog recording 16 3 2 2 The ULTRAMIZER PRO in digital recording and sampling 16 3 2 3 The ULTRAMIZER PRO in mastering 16 3 3 The ULTRAMIZER PRO as a protective device 17 3 3 1 Prot...

Страница 6: ...spectrum into two bands prior to performing the dynamic functions This enables a very musical and effective compression of the program material signal On top of that the ULTRAMIZER PRO also features a...

Страница 7: ...RO is equipped with ten illuminated parameter keys one jog wheel rotary control a numeric display 8 LED indicators and a power switch Each of the two fully independent channels can be monitored with f...

Страница 8: ...ight up in the display can be adjusted The subjec tively felt density of the program material is the result of the amount of compression that is applied The DENSITY can be adjusted from 0 no compressi...

Страница 9: ...can be adjusted ranging from 0 to 100 PROC will light up b Pressed a second time the TUNE parameter can be set Hz will light up Here the TUNE control sets the upper cut off frequency of the super bass...

Страница 10: ...selected voltage Please note that depending on the mains voltage supplied to the unit the correct fuse type and rate must be installed see chapter 6 SPECIFICATIONS Please use the enclosed mains cable...

Страница 11: ...ill perform as a brick wall limiter which will affect transients ULTRAMIZERRANGE The parameter RANGE which you access after pressing the ULTRAMIZER key three times determines the maximal gain the Ultr...

Страница 12: ...parameter 2 1 5 The 3D Surround function With the the 3D surround function the ULTRAMIZER PRO can be used as a 3D stereo surround processor increasing the stereo width of the program material Whether...

Страница 13: ...wer right corner of the display After loading the data the ULTRAMIZER PRO enables the preset and the dot disappears This brief interruption avoids the direct activation of every preset as you scroll t...

Страница 14: ...nge setup The display reads a capital P program Here too four modes can be selected with the jog wheel as follows LVSOD 0RGH 0 No program change data are transmitted 1 Program change data are received...

Страница 15: ...MIZER PRO We are currently developing a software editor which will allow for storing single items of the unit s internal data on an external medium Thus it will be possible to archive ULTRAMIZER PRO s...

Страница 16: ...d In extreme cases it will cause distortion due to tape saturation In contrast to analog side effects in the digital field always become extremely audible with decreasing level a tape previously recor...

Страница 17: ...e damaged by an occasional high level overload e g the sound of a microphone falling onto a hard floor In order to protect a system or the loudspeak ers the application of the BEHRINGER ULTRAMIZER PRO...

Страница 18: ...he dynamic functions of the crossover 3 4 The ULTRAMIZER PRO in combination with a multitrack In connection with multi track machines the BEHRINGER ULTRAMIZER PRO can be used to prevent distor tion ca...

Страница 19: ...mit with the highest obtainable average level and use a multiplicity of signal processors to achieve this despite the effects on the quality of the program material If a limiter with active pre emphas...

Страница 20: ...ish to save When the preset is activated its parameters are transmitted as controller data and can be recorded on a sequencer or similar device Repeat this routine until all presets of your choice hav...

Страница 21: ...IMPORTANT This does not apply for general export models which are built for one operating voltage only The AC voltage selection is defined by the position of the fuse holder If you intend to change th...

Страница 22: ...22 ULTRAMIZER PRO DSP1424P Fig 4 1 Different plug types 4 INSTALLATION All manuals and user guides at all guides com...

Страница 23: ...X X Notes O YES X NO Mode 1 OMNI ON POLY Mode 2 OMNI ON MONO Mode 3 OMNI OFF POLY Mode 4 OMNI OFF MONO Tab 5 1 MIDI implementation chart Parameter Name Display Range Midi Controller Number Controller...

Страница 24: ...socket IN OUT THRU Digital processing Converters 24 bit Sigma Delta 64 128 times oversampling Sampling rate 46 875 kHz Display Type 2 digit numeric LED display Power supply Mains Voltages USA Canada...

Страница 25: ...placed within 30 days of receipt of the product at BEHRINGER 2 If the product needs to be modified or adapted in order to comply with applicable technical or safety standards on a national or local le...

Отзывы: