background image

3

INSTALLATION INSTRUCTIONS EUROLIGHT LD6230

The  BEHRINGER  EUROLIGHT  LD6230  Dimmer  Pack  was

developed to meet the highest demands of light engineering. Its

wide-ranging  functions  make  it  an  all-purpose  workhorse  for

various  commercial  applications  (TV  studios,  theatre  or  live

events).

The EUROLIGHT LD6230 has all the important features needed

to  control  your  lighting  equipment,  yet  its  controls  are  clearly

arranged and simple to use. You can select between digital DMX

or  analog  control.  You  get  trouble-free  operation  with  the

extensive LEDs used for signal error detection.

IMPORTANT INFORMATION

+

Installation  as  well  as  initial  operation  must  be

performed  by  qualified  personnel. 

Always  assure

that  your  LD6230  is  completely  disconnected  from

the  mains  before  removing  the  casing  cover.

+

The  LD6230  was  designed  for  indoor  use  only.

+

Please  keep  in  mind  that  sudden  temperature

changes  (e.g.  bringing  your  equipment  from  colder

environments  into  warmer  environments)  may

cause  condensation  on  electronic  components,

leading  to  possible  equipment  damage  and  physical

harm  to  the  operator.

+

Please  adhere  to  all  applicable  national  safety

standards  during  installation.

+

Please  read  the  installation  instructions  and  the

enclosed  user’s  manual  in  their  entirety  to

familiarize  yourself  with  the  LD6230  and  all  of  its

functions.  Please  follow  all  instructions  and  store

both  the  installation  instructions  and  the  manual  in

a  safe  place  for  future  reference.

+

Please  assure  that  your  EUROLIGHT  is  sufficiently

cooled  and  that  it  is  not  placed  near  heat  sources

that  could  cause  overheating.

+

If you want to run your EUROLIGHT on mains voltage

other  than  factory-specified  voltage,  contact  the

nearest  BEHRINGER  service  center.

+

To  effectively  limit  harmonic  currents  and  avoid

voltage  fluctuations  that  could  affect  other  electrical

appliances,  connect  this  equipment  to  an  AC  outlet

that complies with all applicable technical standards.

In  all  other  cases,  contact  your  local  power  supply

provider  for  advice  prior  to  usage.

MAINS/ILLUMINANT

 

CONNECTORS

To  facilitate  additional  flexibility,  your  dimmer  pack  has  a

connector terminal strip. Cable bushings for connecting to the

mains and your illuminants are located in the back. Flexibility is

further enhanced with the option to retrofit a CEE connector and

a 16-pin HARTING

®

 connector.

Both fixed and mobile installations require compliance with IEC

61010-1:2001  (EN  6110-1:2001).  In  particular,  a  3-phase

separator (pursuant IEC60947-1 and IEC60947-3) needs to be

included in the installation. This separator needs to be labeled

according to IEC 60417-50008 and IEC 0417-5007.

To  assure  compliance  with 

Directive  89/336/EEC

only  use

specified  upstream  line  filters  with  your  EUROLIGHT.  Using  it

without  line  filters  specified  by  BEHRINGER  may  lead  to

electromagnetic interference. More detailed information on this

subject  can  be  found  at  www.behringer.com.

SAFETY AND INITIAL OPERATION

As soon as you connect your LD6230 to the mains, internal

controls are activated. The six 

automated fuses (circuit breakers)

can  all  handle  10  A  and  serve  as  overload  protection  for  the

connected equipment.

+

Please  keep  in  mind  that  activating  circuit  breakers

1,  2,  3,  4,  5  or  6  also  means  that  the  respective

channels  can  conduct  voltage.

Electronic controls are additionally protected with triple high-

sensitivity fuses located on the main board

.

+

Defective  fuses  must  be  replaced  with  fuses  with

identical  rating!

The LD6230 is a Class I device in which a low-Ohm protective

ground wire is an integral part of its safety design.

During the installation, make sure that a low-Ohm protective

conductor (< 0,1 Ohm) exists between all bare metal parts and

the grounding on the main connector.

3KDVH

&+

CH 2

&+

CH 4

&+

CH 6

L1

X

X

L2

X

X

L3

X

X

2XWSXWFKDQQHOV

* Activation of control electronics and respective output channel

CONNECTOR TERMINAL STRIP

The  connector  terminal  strip  of  your  LD6230  is  laid  out  for

cables  with  diameters  between  0.326  mm

2

  (AWG  22)  and

4 mm

2

 (AWG 12). When using flexible access lines, cable end

contacts  corresponding  to  manufacturer  specifications  have

to  be  used.  To  assure  good  contact,  skin  the  cable  endings

between 9 - 13 mm.

During the installation, all applicable national standards need

to be adhered to.

Illustration:  LD6230  connector  terminal  strip

When your LD6230 leaves the assembly plant, all incoming

and  outgoing  neutral  conductor  connectors 

  are  bridged.

The incoming phases L1/L1, L2/L2 and L3/L3 

 are always

connected to one another in pairs and switched to the overload

protection of the channels 1 to 6. They protect output connectors

E1  to  E6 

.  Each  of  the  channels  can  handle  currents  of

maximum 10 Amperes.  The green-yellow conductors 

 (PE)

may only be used as protective conductors.