background image

4

INSTALLATION INSTRUCTIONS EUROLIGHT LD6230

The lowest cable gauge between L1 and L3, incoming neutral

conductor  (N)  and  protective  earth  (PE)  is  4  mm

2

(AWG  12).  For  outgoing  channels  E1  to  E6,  use  cables  with

gauges corresponding to the loads used (2.5 mm

2

 (AWG 14) or

1.5 mm

2

 (AWG 16)).

2XWSXWDVVHVVPHQW>$@

1RPLQDOFURVV

VHFWLRQ>PP

@(8

$:*

86$

6 - 10

1.5

16

13 - 16

2.5

14

18 - 25

4

12

+

During  the  installation,  please  adhere  to  all

manufacturer  instructions. 

Regardless  from  mains

supply  voltage

,  the  maximum  output  current  of  the

EUROLIGHT LD6230 is 10 A per dimmer circle.

+

Please  make  sure  that  each  dimmer  load  is

connected  to  a  separate  channel.  Never  connect

more  than  one  output  to  just  one  common  neutral

conductor.

+

ATTENTION: Due to electrocution danger, do not use

your  dimmer  pack  if  there  are  bare  cables  visible.

CONNECTION OPTIONS FOR

FLEXIBLE USAGE

OUTPUT CONNECTOR (HARTING

®

)

In  the  back  of  your  LD6230  there  is  a  cable  bushing  for

connecting  your  illuminants.  Open  the  flap  on  the  top  of  the

LD6230 to get to the terminal clamps used for this purpose. Here

you have the option to retrofit a 16-pin HARTING

®

 connector. To

do that, you first have to remove the back-bearing cover sheet

and connect the HARTING

®

 connector to the terminal clamps.

PIN 1

Phase channel 1

E1

PIN 9

Neutral channel 1

N

PIN 2

Phase channel 2

E2 PIN 10 Neutral channel 2

N

PIN 3

Phase channel 3

E3 PIN 11 Neutral channel 3

N

PIN 4

Phase channel 4

E4 PIN 12 Neutral channel 4

N

PIN 5

Phase channel 5

E5 PIN 13 Neutral channel 5

N

PIN 6

Phase channel 6

E6 PIN 14 Neutral channel 6

N

PIN 7

free

-

PIN 15

free

-

PIN 8

free

-

PIN 16

free

-

3,1DVV$57,1*

Š

FRQQHFWRU

Ground wires need to be fastened                          

to their respective PE connectors

CEE POWER SUPPLY CONNECTOR

Also  located  in  the  back  is  a  cable  bushing  for  the  mains

supply. Here, you can retrofit a 5-pin CEE 32 A mains connector

by removing the back-bearing cover sheet and connect the CEE

high-voltage connector to the connecting terminal. The following

illustration  shows  how  the  connections  are  allocated:

CEE  connector  pin  allocation

+

Removable  mains  connector  cables  with  mains

interconnections  (pursuant  IEC60320)  must  match

the  minimal  load-carrying  capacity  of  the  connector

or  must  comply  with  the  IEC60799  standard.  The

interconnection  and  the  cable  must  comply  with

prevalent  nominal  values  (maximal  voltage  and

current).

+

During  the  installation,  please  adhere  to  the

instructions  provided  by  the  connector

manufacturer.

SPECIFICATIONS

Channels

Number

6

Load per channel

0.2 A min./10 A max.

Maximal load per channel

10 A using a 3-phase connector

Frequency

50/60 Hz

Inputs

Power  supply

3-phase  connector,  internal

terminal block/PG cable screw

joint, CEE connector (optional

installation by qualified

personnel)

Analog

0 to +10 V via 8 pin DIN

Digital

DMX512 via XLR 5 pin

Outputs

Digital

DMX512 via XLR 5 pin

Load

Internal terminal block/PG cable

screw joint, HARTING

®

 (optional

installation by qualified

personnel)

System  fuses

Load securing per channel

10 A cable protection switch

(type C)

Control section fuse

2 x T 100 mA H/250 V

1 x T 160 mA H/250 V

for voltage range 220 - 230 V (EU)

2 x T 160 mA H/250 V

1 x T 315 mA H/250 V

for voltage range 120 V (UL)

Power  supply

Voltage

USA/Canada

120 V~, 60 Hz

Europe/U.K./Australia

240 V~, 50 Hz

Maximum power consumption 3 x 20 A

Dimensions/Weight

Dimensions (H x W x D)approx. 3 1/3" (84.3 mm)

x 19" (482.6 mm)

x 15 9/10" (403.8 mm)

Weight

approx. 20.3 lbs. (9.2 kg)

BEHRINGER    continuously  strives  to  assure  the  highest  quality

standards possible. Required modifications may be implemented without

prior notice. Technical data and the appearance of the unit may deviate

from the above values and/or illustrations.

All manuals and user guides at all-guides.com