11
SPECIFICATIONS
General Features
Input voltage
Up to 250 V (single phase system) / up to 430 V (three phase system),
50/60 Hz, max 10 A
EVC-20 Test Cable
AC charging mode 3, suitable to IEC 62196-2 type 2 socket outlet or fixed
cable with vehicle connector (type 2, 7P three-phase)
EVC-13 Test Cable
AC charging mode 3, suitable to IEC 62196-2 type 1 or SAE J1772 with
vehicle connector (type 1, 5P single-phase)
Dimensions (W × H × L)
110 × 45 × 220 mm (length without connection cable and test cable)
Weight
Approx. 1 kg
IP-rating
IP54
CE directive
Low Voltage Directive LVD 2014/35/EU
Safety
IEC/EN 61010-1:2010
IEC/EN 61010-2-030:2010
EMC
Not applicable
Working temperature range
0 ... +40 °C
Storage temperature range
-10 ... +50 °C
Reference humidity range
10 ... 60% relative humidity w/o condensation
Working humidity range
10 ... 85% relative humidity w/o condensation
Pollution degree
2
Protection class
II
Measurement category
CAT II 300 V
Altitude above sea level
2000 m max.
Functions
PE Pre-Test
Yes
PP Simulation
Open, 13 A, 20 A, 32 A, 63 A
CP States
A, B, C, D
CP Error “E”
On/off
PE Error (Earth fault)
On/off
Outputs (for test purpose only)
Measuring terminals
L1, L2, L3, N and PE
Max. 250/430 V, CAT II 300 V, max. 10 A
Mains socket
Max. 250 V, CAT II 300 V, allowed current max. 10 A,
Note: Do not load mains socket simultaneously with measuring terminals!
Mains socket protection
Fuse T10A/250V, 5×20 mm, type 179200 produced by Siba
CP Signal output terminals
Approx. +/-12 V, CAT 0 (under normal condition)
In case of wrong wiring or error of the charging station these terminals
may become hazard => up to max. CAT II 300 V against PE