How to Use “Opener-Tool” to Open UK Safety Sockets
To get access to the live and neutral pin of a UK safety socket
you have to release the safety covers first. This could be easily
done by pressing the “Opener-tool” into earth pin of the socket.
How to Use Storage Area for “GS 38 Protective Probe Cap”
2
3
1
W
Disconnect the voltage tester completely from any
measuring circuit first.
• Pull out the “GS 38 protective cap”
1
out of the “test
probe protection cover”, place onto the test probe tips
2
and push firmly to secure it.
• For removal and storage
3
, please perform the
opposite operation.
How to Use Storage Area for “4mm Ø Test Probe Extension”
7
6
8
5
4
1/4 turn
W
Disconnect the voltage tester completely from any
measuring circuit first.
• To retrieve push the “test probe tip” into the “4mm Ø test
probe extension”
4
and twist right it approx.. ¼ turn
5
.
• Then pull on probe
6
to remove “4mm Ø test probe
extension” and continue twisting until “4mm Ø test probe
extension” is tight
7
.
• For removal please do the opposite way
8
and store it
as shown in last picture.