9
GAS CONVERSION INSTRUCTIONS
GAS BOTTLE SAFETY
LPG SAFETY INFORMATION
5� Adjust primary air shutter (if necessary) by loosening the
adjustment screw and rotating shutter to achieve the
desired gap� Refer to “Primary Airation Gap” as defined
in Gas Specification table on page 6 for recommended
gaps for different gas types
6� Replace Burner and cover panel�
When changing gas types it may be necessary to adjust the
valve to achieve the desired turn down setting� This can only
be completed after the connection to the gas supply and leak
test has been conducted�
Adjust the turndown setting on the valve�
To complete the conversion the turndown setting of the valve
will need to be adjusted, and at the same time the operation
of the appliance can be tested� Proceed as follows:
• Check that the burner ignites (REFER OPERATING
INSTRUCTIONS)�
• Light the burner and rotate the control knob to the
lowest setting, then remove the knob from the valve
shaft, and remove the grommet�
• Using a small flat-blade screwdriver adjust the
turndown adjustment screw to achieve a small steady
flame on the burner�
• Replace the grommet and the knob�
• Recheck the operation of the burner at maximum
and turndown�
LPG safety information
• Use only gas cylinders, which meet national and
regional codes� The minimum cylinder size for this
barbecue is 6kg� Ensure that the cylinder can provide
enough fuel to operate the appliance� If in doubt, check
with your local gas supplier�
• Pay attention that when changing the gas cylinder which
shall be carried our away from any source of ignition�
• Never connect a cylinder, which does not meet
local codes�
• All cylinders 7kg or larger must be placed on the ground
at the rear of the barbecue� Cylinders smaller than 7kg
(maximum size 465mm high by 306mm wide) may be
placed on the hook at the rear (as shown)� Cylinders
must not be exposed to extreme heat or direct sunlight�
• The isolation valve must be turned off when the
appliance is not in use�
• Gas cylinders must be stored in an approved housing out
of reach of children�
• When disconnecting the gas bottle ensure that all the
control valves are in the ‘OFF’ position�
• When reconnecting the hose to the bottle, ensure that
all connections are tight before replacing in storage
compartment�
• Carry out a leakage check as detailed below after each
reconnection�
• Only regulator which complies with EN 16129 can be
used�
• The length of hose cannot exceed 1�5m� In Finland, the
length of hose cannot exceed 1�2m�
• It’s necessary to change the flexible tube when the
national conditions require it, and/or depending on its
validity�
• Make sure that the flexible tube is not subjected to
twisting when the appliance is in operation�
Turndown adjustment screw
Burner
Primary
air shutter
Screw
Primary
air gap