GAS SPECIFICATIONS
GAS SPECIFICATIONS
NOTES:
• This appliance MUST be serviced only by a qualified
licensed person�
• This appliance is designed to be used outdoors and well
ventilated indoor areas�
• This product must be installed as per the instructions
which requires the installation of venting to enable
the barbecue to operate correctly� Failure to provide
adequate ventilation for supply of air to the appliance
may result in poor burner performance or excessive
heat build-up within the mounting enclosure�
• Ventilation holes in the unit must not be obscured by the
installation�
Failure to adhere to these installation instructions may
affect your ability to make a claim under the manufacturer’s
warranty�
408mm
46mm
137mm
COUNTRY
BE, FR, IT, LU, IE,
GB, GR, PT, ES,
CY,CZ, LT, SK, CH,
SI, LV
LU, NL, DK, FI,
SE, CY, CZ, EE,
LT, MT, SK, SI,
BG, IS, NO, TR,
HR, RO, IT, HU,
LV
PL
AT, DE, SK, CH,
LU
FR, IT, DK, IE,
GB, GR, ES, PT,
AT, FI, SE, CZ,
EE, HU, LV, LT,
SK, SI, IS, NO,
CH, TR, HR, RO
DE, LU, PL, NL
CATEGORY
I3+(28–30/37)
I3B/P (30)
I3B/P (37)
I3B/P (50)
I2H
I2E
TYPE
Butane Propane
BUTANE, PROPANE OR THEIR MIXTURES
NATURAL GAS
GAS INLET
PRESSURE
(MBAR)
28-30
37
28-30
37
50
20
INJECTOR Ø
(MM)
0�90
0�85
0�78*
1�30
TOTAL HEAT
INPUT
18�6 kW (1354 g/h for LPG)
17�2kW
* When installed with a second stage regulator reducing pressure to 28-30mbar there is no requirement to change the factory
fitted injectors�