INSTALLATION WARNINGS
UNIVERSAL LPG AND PROPANE INSTALLATION
WARNING
WARNING
• This appliance shall only be used in an above ground,
open air situation with natural ventilation without
stagnant areas, where gas leakage and products of
combustion are rapidly dispersed by wind or natural
convection. This appliance is designed to be used
outdoors and well ventilated indoor areas. Failure to
adhere to these installation instructions may cause
injury or property damage and affect your ability to
make a claim under the manufacturer’s warranty.
Refer to diagrams below.
• Never install this barbecue inside any building,
garage, shed or breezeway or inside a boat, caravan or
recreational vehicle� This is to prevent the possibility of
fire or carbon monoxide poisoning or asphyxiation�
• Any enclosure in which this appliance is installed shall
comply with one of the following:
– An enclosure with walls on all sides, but at least
one permanent opening at the ground level and no
overhead covering
– Within a partial enclosure that includes an overhead
cover and no more than 2 walls
– Within a partial enclosure that includes an overhead
cover and more than 2 walls, the following shall apply:
– at least 25% of the total wall area is completely open
and at least 30% of the remaining wall area is open
and unrestricted
• In the case of balconies, at least 20% of the total of the
side, back and front wall areas shall be and remain open
and unrestricted�