IMPORTANT
INSTRUCTIONS:
USER
OPERATING
MANUAL
MODEL
SKU:
VET
‐
800NA
Revision
1.0
P a g e
|
11
Troubleshooting
Cont.
Diagnose
&
Fix
Issue
Possible
Causes
Action
Remote
control
will
not
operate
BedJet
Dead
battery
in
remote
Remote
control
may
need
to
be
re
‐
paired
to
your
BedJet
Make
sure
remote
control
LED
lights
up
when
picked
up,
if
not
then
replace
battery
Re
‐
pair
remote
control
to
BedJet
with
instructions
on
page
7
Remote
control
commands
are
not
acknowledged
with
an
audible
beep
anymore
Audio
alert
mute
may
have
been
accidentally
turned
on
Press
Mute
button
on
remote
control
to
unmute
BedJet
keeps
shutting
off
without
a
shutoff
command
being
given
or
beep;
BedJet
power
button
LED
is
ON
and
ERROR
LED
is
NOT
flashing
and
BedJet
can
be
restarted
normally
This
is
normal.
Once
turned
on,
every
mode
has
an
automatic
shutoff
timer.
Please
see
page
8
for
information
about
auto
‐
shutoff
time
limits.
Shutoff
Timer
can
be
advanced
within
certain
limits
using
TIME
+/
‐
button
BedJet
ERROR
display
LED
is
flashing
and
unit
will
no
longer
operate,
BedJet
beeps
5
times
The
BedJet
microprocessor
has
discovered
a
monitoring
error
within
the
system.
This
does
not
always
mean
your
BedJet
is
malfunctioning
and
may
occur
if
you
rapidly
change
modes
or
airflow
while
at
the
same
time
obstructing
inlets
or
outlets.
Check
to
make
sure
air
filter
is
clean
and
there
are
no
air
inlet
or
outlet
obstructions.
Unplug
BedJet
for
30
seconds,
run
in
cool
mode
for
2
minutes
and
then
retry
warming
mode.
If
this
does
not
solve
the
problem,
or
if
the
problem
occurs
again,
contact
BedJet
support
and
record
the
number
of
blinking
flashes
from
the
Error
display
LED.
BedJet
delivered
warm
air
but
then
while
still
in
warming
mode
is
blowing
cold
air
In
addition
to
real
‐
time
microprocessor
control
of
the
heat,
the
BedJet
contains
multiple
mechanical
‐
thermal
overheat
switches
for
your
protection.
They
are
extremely
sensitive
and
may
have
disabled
the
heater
unit.
They
are
self
‐
resetting
but
remain
open
until
power
is
removed
and
the
unit
is
allowed
to
cool
off.
They
may
have
been
triggered
by
inlet
or
outlet
blockages.
Check
to
make
sure
air
filter
is
clean
and
there
are
no
air
inlet
or
outlet
obstructions.
Unplug
BedJet
for
30
seconds,
run
in
cool
mode
for
2
minutes
and
then
retry
warming
mode.
If
this
does
not
solve
the
problem,
or
if
the
problem
occurs
again,
contact
BedJet
support.