© BECOM Systems 2021
17
|
25
Hardware User Manual - TOREO-P650
Last change: 6 September 2021/Version 1
5
Electrical Specification
5.1
Absolute maximum rating
Stresses above the absolute maximum ratings listed in Table 5.1 may cause permanent damage to the device.
These are stress ratings only and functional operation of the device at these conditions is not implied. Exposure to
maximum rating conditions for extended periods may affect device reliability.
Symbol
Parameter
Conditions
Min
Max Unit
V
IN
DC supply voltage
-40
40
V
V
IRST
Reset Input
-0.3
36
V
V
ITRG
Trigger Input
-0.3
36
V
T
A
Ambient temperature
-40
60
°C
Table 5.1: Absolute maximum ratings
5.2
Operating conditions
Symbol
Parameter
Conditions
Min
Max Unit
V
IN
DC supply voltage
20
30
V
I
IN_INT
Input supply current during integration
Vin = 24 V
6.55
A
I
IN_IDL
Input supply between integration phases
Vin = 24 V
0.4
A
P
INT
Peak Input Power during integration
Vin = 24 V
157.2 W
V
IH
Reset and trigger input high level
1.2
30
V
V
IL
Reset and trigger input low level
1.2
30
V
I
SR
Solid state relay input current
0
200
mA
R
SR_ON
Solid state relay on resistance
10
Ω
Table 5.2: Operating conditions