background image

Foreword

KL6301-0000

5

Version: 3.0.0

1

Foreword

1.1

Notes on the documentation

Intended audience

This description is only intended for the use of trained specialists in control and automation engineering who
are familiar with the applicable national standards.
It is essential that the documentation and the following notes and explanations are followed when installing
and commissioning these components.
It is the duty of the technical personnel to use the documentation published at the respective time of each
installation and commissioning.

The responsible staff must ensure that the application or use of the products described satisfy all the
requirements for safety, including all the relevant laws, regulations, guidelines and standards.

Disclaimer

The documentation has been prepared with care. The products described are, however, constantly under
development.

We reserve the right to revise and change the documentation at any time and without prior announcement.

No claims for the modification of products that have already been supplied may be made on the basis of the
data, diagrams and descriptions in this documentation.

Trademarks

Beckhoff

®

, TwinCAT

®

, EtherCAT

®

, EtherCAT P

®

, Safety over EtherCAT

®

, TwinSAFE

®

, XFC

®

 and XTS

®

 are

registered trademarks of and licensed by Beckhoff Automation GmbH.
Other designations used in this publication may be trademarks whose use by third parties for their own
purposes could violate the rights of the owners.

Patent Pending

The EtherCAT Technology is covered, including but not limited to the following patent applications and
patents: EP1590927, EP1789857, DE102004044764, DE102007017835 with corresponding applications or
registrations in various other countries.

The TwinCAT Technology is covered, including but not limited to the following patent applications and
patents: EP0851348, US6167425 with corresponding applications or registrations in various other countries.

EtherCAT

®

 is registered trademark and patented technology, licensed by Beckhoff Automation GmbH,

Germany.

Copyright

© Beckhoff Automation GmbH & Co. KG, Germany.
The reproduction, distribution and utilization of this document as well as the communication of its contents to
others without express authorization are prohibited.
Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a
patent, utility model or design.

Содержание KL6301-0000

Страница 1: ...Documentation KL6301 0000 EIB KNX Bus Terminal 3 0 0 2019 05 24 Version Date...

Страница 2: ......

Страница 3: ...echnical data 10 3 Mounting and wiring 11 3 1 Installation on mounting rails 11 3 2 Connection 13 3 2 1 Connection system 13 3 2 2 Wiring 15 3 3 Connection 17 3 4 Installation instructions for enhance...

Страница 4: ...Table of Contents KL6301 0000 4 Version 3 0 0...

Страница 5: ...ata diagrams and descriptions in this documentation Trademarks Beckhoff TwinCAT EtherCAT EtherCAT P Safety over EtherCAT TwinSAFE XFC and XTS are registered trademarks of and licensed by Beckhoff Auto...

Страница 6: ...trained specialists in control automation and drive engineering who are familiar with the applicable national standards Description of instructions In this documentation the following instructions ar...

Страница 7: ...can also be used with firmware version B0 In that case however only the 4 filters with 64 entries each are possible 1 2 0 Mounting description expanded 1 1 0 New output variable in receive function bl...

Страница 8: ...inCAT function blocks IEC61131 3 Software required for use of the KL6301 1 An ETS tool for linking the data and commissioning the other EIB KNX devices 2 TwinCAT PLC and an appropriate library to comm...

Страница 9: ...or strongly K bus communication OK No K Bus communication K Bus communication Set green No significance EIB TXD green Goes out briefly when an EIB telegram is sent EIB RXD POWER green Goes out briefly...

Страница 10: ...Output 24 bytes data input 24 bytes data Weight approx 85 g Dimensions W x H x D approx 12 mm x 100 mm x 70 mm Mounting 11 on 35 mm mounting rail conforms to EN 60715 Permissible ambient temperature r...

Страница 11: ...the fieldbus coupler Join the compo nents with tongue and groove and push the terminals against the mounting rail until the lock clicks onto the mounting rail If the terminals are clipped onto the mou...

Страница 12: ...ponents The six spring contacts of the K Bus E Bus deal with the transfer of the data and the supply of the Bus Terminal electronics The power contacts deal with the supply for the field electronics a...

Страница 13: ...10 mm from the group of terminals WARNING Risk of electric shock The PE power contact must not be used for other potentials 3 2 Connection 3 2 1 Connection system WARNING Risk of electric shock and da...

Страница 14: ...minates the risk of wires being mixed up The familiar dimensions of the terminal only had to be changed slightly The new connector adds about 3 mm The maximum height of the terminal remains unchanged...

Страница 15: ...disassembly or wiring of the Bus Terminals Terminals for standard wiring ELxxxx KLxxxx and for pluggable wiring ESxxxx KSxxxx Fig 9 Connecting a cable on a terminal point Up to eight terminal points...

Страница 16: ...he HD Terminals are connected without tools for single wire conductors using the direct plug in technique i e after stripping the wire is simply plugged into the terminal point The cables are released...

Страница 17: ...No Connection for Set 1 reserved EIB 2 EIB plus red internally connected with terminal point 6 EIB 3 EIB minus grey internally connected with terminal point 7 Shield 4 Shield internally connected wit...

Страница 18: ...cal load capacity the following additional installation instructions apply The enhanced mechanical load capacity is valid for all permissible installation positions Use a mounting rail according to EN...

Страница 19: ...against the rated operating voltage being exceeded by more than 40 due to short term interference voltages The individual terminals may only be unplugged or removed from the Bus Terminal system if the...

Страница 20: ...the Beckhoff terminal systems in potentially explosive ar eas ATEX Pay also attention to the continuative documentation Notes about operation of the Beckhoff terminal systems in potentially explosive...

Страница 21: ...sequent EIB data can only be transferred to the KL6301 after a successful transfer Two types of EIB telegrams can be sent WRITE_GROUP for writing data to other EIB devices READ_GROUP_REQ for requestin...

Страница 22: ...rogramming KL6301 0000 22 Version 3 0 0 5 Programming 5 1 TwinCAT libraries Software documentation in the Beckhoff Information System TwinCAT 2 TwinCAT 2 PLC Lib EIB TwinCAT 3 TwinCAT 3 PLC Lib Tc2_EI...

Страница 23: ...off components there Beckhoff Headquarters Beckhoff Automation GmbH Co KG Huelshorstweg 20 33415 Verl Germany Phone 49 0 5246 963 0 Fax 49 0 5246 963 198 e mail info beckhoff com Beckhoff Support Supp...

Страница 24: ...2 KL6301 Diagnostic LEDs 9 Fig 3 Attaching on mounting rail 11 Fig 4 Disassembling of terminal 12 Fig 5 Power contact on left side 13 Fig 6 Standard wiring 14 Fig 7 Pluggable wiring 14 Fig 8 High Dens...

Отзывы: