Product overview

KL2819

12

Version: 1.1.0

Fig. 4: Switch-off of inductive loads

Содержание KL2819

Страница 1: ...Documentation EN KL2819 HD Bus Terminal 16 channel digital output 24 V DC with diagnostics 2022 02 11 Version 1 1 0...

Страница 2: ......

Страница 3: ...4 3 Connection 21 4 3 1 Connection system 21 4 3 2 Wiring 23 4 3 3 Shielding 24 4 4 Installation positions 24 4 5 Disposal 26 5 KS2000 Configuration software 27 5 1 KS2000 Introduction 27 5 2 Paramet...

Страница 4: ...Table of contents KL2819 4 Version 1 1 0...

Страница 5: ...oducts that have already been supplied may be made on the basis of the data diagrams and descriptions in this documentation Trademarks Beckhoff TwinCAT TwinCAT BSD TC BSD EtherCAT EtherCAT G EtherCAT...

Страница 6: ...ained specialists in control automation and drive engineering who are familiar with the applicable national standards Description of instructions In this documentation the following instructions are u...

Страница 7: ...s Documentation Version KL2819 Firmware Hardware 1 1 0 1B 02 1 0 0 1A 00 The firmware and hardware versions delivery state can be taken from the serial number printed on the side of the terminal Synta...

Страница 8: ...e lack of a voltage supply to the terminal are supplied as diagnostic information Moreover each of the channels can signal e g a short circuit The switching state and any error of the output are indic...

Страница 9: ...put 2 2 Output 2 Output 3 3 Output 3 Output 4 4 Output 4 Output 5 5 Output 5 Output 6 6 Output 6 Output 7 7 Output 7 Output 8 8 Output 8 Output 9 9 Output 9 Output 10 10 Output 10 Output 11 11 Output...

Страница 10: ...approx 70 g Mounting on 35 mm mounting rail according to EN 60715 Permissible ambient temperature range during operation 0 C 55 C Permissible ambient temperature range during storage 25 C 85 C Permiss...

Страница 11: ...verload The clock frequency depends on the ambient temperature and the load of the other terminal channels This overload cause the device temperature to rise further If several channels are overloaded...

Страница 12: ...Product overview KL2819 12 Version 1 1 0 Fig 4 Switch off of inductive loads...

Страница 13: ...attention to the information about the hardware version and non reactivity of the respective Bus Terminal in the chapters Technical Data or Firmware Compatibility Only terminals with the appropriate...

Страница 14: ...n to mandatory requirements there are also optional requirements of which only one needs to be selected No switching of loads with a separate power supply Loads that have their own power supply must n...

Страница 15: ...potential in order to be able to achieve Cat 4 PLe according to EN ISO 13849 1 2007 or SIL3 according to IEC 61508 2010 refer here to the overview in the chapter Effect of options on the safety level...

Страница 16: ...ty 4 Cable permanently fixed installed and protected against external damage All conductors connected to the non safe standard terminals are permanently fixed and e g protected against external damage...

Страница 17: ...ure you are electrostatically discharged and avoid touching the contacts of the device directly Avoid contact with highly insulating materials synthetic fibers plastic film etc Surroundings working pl...

Страница 18: ...coupler Join the compo nents with tongue and groove and push the terminals against the mounting rail until the lock clicks onto the mounting rail If the terminals are clipped onto the mounting rail fi...

Страница 19: ...nents The six spring contacts of the K Bus E Bus deal with the transfer of the data and the supply of the Bus Terminal electronics The power contacts deal with the supply for the field electronics and...

Страница 20: ...sting or to damage on the terminal e g disruptive discharge to the PE line during insulation testing of a consumer with a nominal voltage of 230 V For insulation testing disconnect the PE supply line...

Страница 21: ...sity Standard wiring ELxxxx KLxxxx Fig 12 Standard wiring The terminals of ELxxxx and KLxxxx series have been tried and tested for years They feature integrated screwless spring force technology for f...

Страница 22: ...he terminals from these series with 16 terminal points are distinguished by a particularly compact design as the packaging density is twice as large as that of the standard 12 mm bus terminals Massive...

Страница 23: ...t toggle 2 The wire can now be inserted into the round terminal opening without any force 3 The terminal point closes automatically when the pressure is released holding the wire securely and permane...

Страница 24: ...r to the technical data for a terminal to ascertain whether any restrictions regarding the installa tion position and or the operating temperature range have been specified When installing high power...

Страница 25: ...in Fig Recommended distances for standard installation position is recommended Other installation positions All other installation positions are characterized by different spatial arrangement of the...

Страница 26: ...Disposal Products marked with a crossed out wheeled bin shall not be discarded with the normal waste stream The device is considered as waste electrical and electronic equipment The national regulati...

Страница 27: ...s Box Modules can be prepared before the commissioning phase Later on this configuration can be transferred to the terminal station in the commissioning phase by means of a download For documentation...

Страница 28: ...r s input and output images can be observed by monitoring Process values can be specified in the output image for commissioning of the output modules All possibilities in the online mode can be used i...

Страница 29: ...fieldbus station terminals In the tree structure of the left hand window click on the plus sign next to the terminal whose parameters you wish to change item 1 in the example Fig 20 KS2000 tree branc...

Страница 30: ...ation software KL2819 30 Version 1 1 0 5 3 Register You can access the registers of the KL2819 directly under Register The meaning of the register is explained in the register overview Fig 21 Register...

Страница 31: ...cess Register access 0 process data mode enabled SB 6 DCF Diagnostic Common Fault A diagnostic common fault OR Combination of all Faults SB 5 MV Missing Voltage No Voltage for the Outputs Up 10 V SB 4...

Страница 32: ...0dec R8 33 Terminal type 0x0B03 2819dec R ROM R9 33 Firmware version number 0x3141 1AASCII R ROM R10 33 Multiplex shift register 0x0118 280dec R ROM R11 33 Signal channels 0x0118 280dec R ROM R12 33 M...

Страница 33: ...he MSB is set the control and status byte is not necessarily required for the terminal function and is not transferred to the control if the Bus Coupler is configured accordingly R13 Data structure da...

Страница 34: ...on active on channel 1 Diagnostic function not active on channel Default 0xFFFF 65535dez Bit R33 15 R33 14 R33 13 R33 12 R33 11 R33 10 R33 9 R33 8 Name Diag on Channel 16 Diag on Channel 15 Diag on Ch...

Страница 35: ...ol byte as a receipt in the status byte The terminal returns the firmware version 0x3341 in the input data word byte 1 and byte 2 This is to be interpreted as an ASCII code ASCII code 0x33 represents...

Страница 36: ...switched on Bit 0 6 not set means reading the register Bits 0 5 to 0 0 specify the register number 31 with 01 1111bin The output data word byte 1 and byte 2 has no meaning during read access Input Da...

Страница 37: ...Output Data Byte 0 Control byte Byte 1 DataOUT1 high byte Byte 2 DataOUT1 low byte 0xA0 1010 0000bin 0xXX 0xXX Explanation Bit 0 7 set means Register communication switched on Bit 0 6 not set means r...

Страница 38: ...IN1 high byte Byte 2 DataIN1 low byte 0x9F 1001 1111bin 0xXX 0xXX Explanation The terminal returns a value as a receipt in the status byte that differs only in bit 0 6 from the value of the control by...

Страница 39: ...ents there Beckhoff Support Support offers you comprehensive technical assistance helping you not only with the application of individual Beckhoff products but also with other wide ranging services su...

Страница 40: ...ng 16 Fig 8 Spring contacts of the Beckhoff I O components 17 Fig 9 Attaching on mounting rail 18 Fig 10 Disassembling of terminal 19 Fig 11 Power contact on left side 20 Fig 12 Standard wiring 21 Fig...

Страница 41: ......

Страница 42: ...Beckhoff Automation GmbH Co KG H lshorstweg 20 33415 Verl Germany Phone 49 5246 9630 info beckhoff com www beckhoff com More Information www beckhoff com KL2819...