Maintenance
CP32xx-2xxx-0020
31
Version: 1.1
6.2
Maintenance
NOTE
Use of incorrect spare parts
The use of spare parts not ordered from Beckhoff Service can lead to unsafe and faulty operation.
• Only use spare parts that you have ordered from Beckhoff Service.
Beckhoff Panel PCs are manufactured from components of the highest quality and robustness. They are
selected and tested for best interoperability, long-term availability and reliable function under the specified
environmental conditions.
Nevertheless, some components of the Panel PC may be subject to a limited service life if they are operated
under certain conditions, such as more demanding ambient conditions during operation or during storage, or
if they are out of service for long periods of storage.
Beckhoff therefore recommends replacing some of the Industrial PC components after the time after which
predictions of the remaining service life of such components can no longer be reliably calculated.
These are the following components:
• Storage media
• Battery
• Fan
The following table provides recommendations for regular replacement of PC components:
Table 9: Replacement recommendations for PC components
Component
Recommendation for replacement intervals (years)
UPS battery pack
5 years
2.5-inch hard disk
5 years or after 20,000 operating hours at more than 40
°C or after 30,000 operating hours at less than 40 °C
3.5-inch hard disk
5 years, irrespective of the operating hours
Fan
7 years
Compact Flash, CFast or SSD
10 years
Motherboard battery
5 years
Beckhoff is excluded from liability in the event of possible damage occurring during maintenance work.
Before working on the device, you should have established ESD protection to prevent damage to the device
through electrostatic discharge.
ESD protection
NOTE
Electrostatic discharge
Handling the Panel PC without ESD protection can lead to malfunctions and destruction of the device.
• Provide an ESD protected working environment for handling the device.
When working on electronic devices, there is a risk of damage due to ESD (electrostatic discharge), which
can impair the function or destroy the device.
Protect the Panel PC and create an ESD-protected working environment in which existing electrostatic
charges are safely discharged to ground and charging is prevented.
The best way to create an ESD-protected working environment is to set up ESD protection zones. The
following measures serve this purpose:
• ESD-compliant floors with sufficient conductivity to the reference potential PE;
• ESD-compatible, dissipative clothing such as shoes and safety shoes, protective gloves, protective
clothing over normal clothing;
Содержание CP32 -2 -0020 Series
Страница 1: ...Manual EN CP32xx 2xxx 0020 Panel PC 3 26 2021 Version 1 1...
Страница 2: ......
Страница 4: ...Table of contents CP32xx 2xxx 0020 4 Version 1 1...
Страница 34: ...Maintenance CP32xx 2xxx 0020 34 Version 1 1 1 2 Fig 22 CP32xx_battery and fans...
Страница 44: ......