background image

Notes on the documentation

CP29xx

5

Version: 3.1

1

Notes on the documentation

This description is only intended for the use of trained specialists in control and automation engineering who
are familiar with the applicable national standards.

The following instructions and explanations must be followed during installation and commissioning of the
components. The responsible staff must ensure that the application or use of the products described satisfy
all the requirements for safety, including all the relevant laws, regulations, guidelines and standards.

Disclaimer

The documentation has been prepared with care. The products described are, however, constantly under
development. For that reason the documentation is not in every case checked for consistency with
performance data, standards or other characteristics. In the event that it contains technical or editorial errors,
we retain the right to make alterations at any time and without warning. No claims for the modification of
products that have already been supplied may be made on the basis of the data, diagrams, and descriptions
in this documentation. All illustrations shown are only examples. The configurations depicted may deviate
from the standard.

Trademarks

Beckhoff

®

, TwinCAT

®

, TwinCAT/BSD

®

, TC/BSD

 ®

, EtherCAT

®

, EtherCAT G

®

, EtherCAT G10

®

, EtherCAT P

®

,

Safety over EtherCAT

®

, TwinSAFE

®

, XFC

®

, XTS

®

 and XPlanar

®

 are registered and licensed trademarks of

Beckhoff Automation GmbH.
Other designations used in this publication may be trademarks whose use by third parties for their own
purposes could violate the rights of the owners.

Patents

The EtherCAT Technology is covered, including but not limited to the following patent applications and
patents: EP1590927, EP1789857, DE102004044764, DE102007017835 with the corresponding applications
and registrations in various other countries. The TwinCAT Technology is covered, including but not limited to
the following patent applications and patents: EP0851348, US6167425 with corresponding applications or
registrations in various other countries.

Copyright

© Beckhoff Automation GmbH & Co. KG. Publication of this document on websites other than ours is
prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of the
grant of a patent, utility model or design.

Delivery state

All the components are supplied in particular hardware and software configurations appropriate for the
application. Changes to the hardware or software configuration are permitted, provided they are within the
specified limits for power consumption and power dissipation (please refer to the respective data sheet).

Delivery conditions

In addition, the general delivery conditions of the company Beckhoff Automation GmbH & Co. KG apply.

Содержание CP29 Series

Страница 1: ...Manual EN CP29xx Control Panel 8 11 2021 Version 3 1...

Страница 2: ......

Страница 3: ...7 3 3 3 CP Link 4 18 3 4 Optional USB interface 21 3 5 Name plate 23 3 6 Connection cables connection kits 24 3 6 1 CP29xx 0000 connection kits 24 3 6 2 CP29xx 0010 connection cables 25 4 Commissionin...

Страница 4: ...Table of contents CP29xx 4 Version 3 1...

Страница 5: ...rCAT EtherCAT G EtherCAT G10 EtherCAT P Safety over EtherCAT TwinSAFE XFC XTS and XPlanar are registered and licensed trademarks of Beckhoff Automation GmbH Other designations used in this publication...

Страница 6: ...h built in Control Panel is designed for industrial applications in machine and plant engineering A display with multi finger touch screen is installed in an aluminum housing The Control Panel is inst...

Страница 7: ...ith a control and automation technology background operate the device Use by unauthorized persons can lead to damage to property and loss of data Protect the power supply cable with a fuse with a max...

Страница 8: ...finger touch screen PCT e g for 10 finger touch Aluminum housing with glass front IP65 at the front IP20 at the rear the housing surface is electrically insulating CP29xx 0000 interfaces 2x USB output...

Страница 9: ...Product overview CP29xx 9 Version 3 1 1 2 Fig 1 CP29xx_without and with push button extension...

Страница 10: ...2 Clamping lever Mounting the Control Panel in the control cabinet 3 Connection block Access to the interfaces 4 Name plate Information on the Control Panel equipment 5 Power supply X101 Connection o...

Страница 11: ...socket pin numbering Table 2 Voltage socket pin assignment Pin Signal Description 1 NC not used 2 NC not used 3 Protective earth 4 24 V power supply negative pole 5 24 V 24 V power supply positive pol...

Страница 12: ...ported for connection distances up to 3 m USB specification 2 0 is supported for connection distances of more than 3 m or when USB E is used 1 2 3 4 4 3 2 1 X102 X103 5 6 7 8 9 5 6 7 8 9 Fig 4 CP29xx...

Страница 13: ...B specification 3 0 is supported for connection distances up to 3 m USB specification 2 0 is supported for connection distances up to 5 m 1 2 3 4 X104 5 6 78 9 Fig 5 CP29xx_USB input pin numbering Tab...

Страница 14: ...cable i e not crossed The interface transmits USB 2 0 with 480 Mbit s The socket does not represent an Ethernet connection To realize a distance of 50 m without hubs USB Extended converts the USB sign...

Страница 15: ...o fully restore the DVI signal The Industrial PC requires a conventional DVI output 1 8 16 24 17 9 X106 Fig 7 CP29xx_DVI Extended input pin numbering Table 6 DVI Extended interface pin assignment Pin...

Страница 16: ...Panel is required via the voltage socket X101 1 2 3 4 5 Fig 8 CP29xx_voltage socket pin numbering Table 7 Voltage socket pin assignment Pin Signal Description 1 NC not used 2 NC not used 3 Protective...

Страница 17: ...USB outputs X102 X103 with type A sockets They are used to connect peripheral devices with USB interfaces USB specification 2 0 is supported 1 2 3 4 4 3 2 1 X102 X103 Fig 9 CP29xx USB interface pin n...

Страница 18: ...dustrial PC via the module USB 2 0 100 MBit s and DVI are transmitted together via a CP Link 4 cable An additional power supply is required for the CP29xx 0010 see Fig 11 24 V 24 V CAT 6A 100 m C6032...

Страница 19: ...e Control Panel via the CP Link 4 connection of the transmitter box using a CP Link 4 cable With this box USB DP DVI and power supply can be transmitted together via the cable One Cable Display Link N...

Страница 20: ...Product overview CP29xx 20 Version 3 1 CU8802 0001 CU8803 0000 CU8803 0001...

Страница 21: ...the right side of the cover section A The cover protrudes slightly from the left side of the device section B 2 Turn the cover downwards section C The USB interface is now accessible section D A B C...

Страница 22: ...2 Version 3 1 Table 11 Optional USB interface pin assignment Pin Connection Shield GND 1 Vbus 2 D 3 D 4 GND 5 StdA_SSRX 6 StdA_SSRX 7 GND_DRAIN 8 StdA_SSTX 9 StdA_SSTX For USB 2 0 only pins 1 to 4 and...

Страница 23: ...5 Touch screen 6 Power supply 24 VDC NEC class 2 7 DVI Extended interface X106 8 USB Extended Interface X105 9 USB input X104 10 USB output X102 X103 11 Ground connection for functional earthing of t...

Страница 24: ...nverter for DIN rail mounting next to the PC and 1 m USB cable for connecting the USB to USB E 2 0 converter to the PC C9900 K626 20 m connection kit for CP29xx 0000 consisting of 20 m DVI cable 20 m...

Страница 25: ...e CAT 6A 70 m C9900 K680 RJ45 connection cable CAT 6A 80 m C9900 K681 RJ45 connection cable CAT 6A 90 m C9900 K682 RJ45 connection cable CAT 6A 100 m C9900 K725 RJ45 connection cable CAT 6A 3 m drag c...

Страница 26: ...900 T225 Adhesive protective film for Panel PCs and Control Panels with 7 inch display for fitting onto the glass pane 1 item C9900 T226 Adhesive protective film for Panel PCs and Control Panels with...

Страница 27: ...film for Panel PCs and Control Panels with 21 5 inch display for fitting onto the glass pane ex works C9900 T224 Adhesive protective film for Panel PCs and Control Panels with 24 inch display for fit...

Страница 28: ...to the device Protect the device against moisture condensation during transport in cold weather or in case of ex treme temperature fluctuations Do not put the device into operation until it has slowly...

Страница 29: ...Technical Data 41 4 2 1 Dimensions The dimensions of the Control Panel are required for preparing the control cabinet For the installation of the Control Panel the wall thickness must be between 1 mm...

Страница 30: ...position of the screen for guidance This should always be optimally visible to the user Do not expose the Control Panel to direct sunlight Installation in the control cabinet Once you have made the r...

Страница 31: ...r supply unit is required to supply 24 V DC 15 20 for operating the device Connect the Control Panel in the control cabinet according to standard EN 60204 1 2006 Protective Extra Low Voltage PELV The...

Страница 32: ...rrules into the 5 pin connection strip The pin assignment of the connector can be found in chapter 3 2 1 Power supply 11 for CP29xx 0000 or chapter 3 3 1 Power supply 16 for CP29xx 0010 4 Screw the ca...

Страница 33: ...Commissioning CP29xx 33 Version 3 1 Fig 19 CP29xx_Disassembly the strain relief housing...

Страница 34: ...ware damage due to electromagnetic inter ference Only use the device with functional earth Electromagnetic compatibility EMC of the Control Panel includes on the one hand not affecting other devices a...

Страница 35: ...ith UPS output we recommend using this for connecting the Control Panel For CP Link 4 we recommend connecting the CU880x transmitter boxes to the UPS output of the PC Connecting the power supply Cable...

Страница 36: ...pply is switched on may cause damage to the transmitter box Switch off the power supply to the CU8803 transmitter box before disconnecting the CP Link 4 connec tion Before removing the Control Panel y...

Страница 37: ...teps shown in Fig 20 1 Loosen the clamping levers with a 3 0 mm Allen key sections A and B 2 Fold the clamping levers back by 90 onto the housing section C You can now remove the Panel from the contro...

Страница 38: ...or this Never use compressed air to clean the Panel Cleaning agents In order to avoid damage to the front of the Control Panel during cleaning you must use suitable cleaning agents Examples include be...

Страница 39: ...tenance CP29xx 39 Version 3 1 Fig 22 CP29xx_Cleaning mode configuration Repair Only the manufacturer may repair the device If a repair should be necessary contact Beckhoff Service see Chapter 9 1 Serv...

Страница 40: ...ng functional earth of the device Poor or missing ground connection of the user Check equipotential bonding and grounding measures Touch control panel frame and check touch function at the same time U...

Страница 41: ...IP65 rear side IP20 Vibration resistance sinusoidal vibration EN 60068 2 6 10 to 58 Hz 0 035 mm 58 to 500 Hz 0 5 G 5 m s2 Shock resistance shock EN 60068 2 27 5 G 50 m s2 duration 30 ms EMC interferen...

Страница 42: ...n find on the name plate Beckhoff Support Support offers you comprehensive technical assistance helping you not only with the application of individual Beckhoff products but also with other wide rangi...

Страница 43: ...to provide adequate protection against adverse interference if the device is used in a commercial environment This device generates uses and may emit radio frequency energy and may cause adverse inte...

Страница 44: ......

Страница 45: ...Beckhoff Automation GmbH Co KG H lshorstweg 20 33415 Verl Germany Phone 49 5246 9630 info beckhoff com www beckhoff com More Information www beckhoff com cp29xx...

Отзывы: