Becker Avionics
Installation
Aircraft Wiring
DV17551.03 Issue 03 June 2020
RCU6512
31
2.6 Equipment Configuration Samples
RCU6512 with RT6512
RT6512 transceiver operated by RCU6512 controller using the RS422 interface.
Figure 8: RCU6512 with RT6512
Dual controller configuration for tandem operations is not available
with RCU6512.
2.7 Aircraft Wiring
The installation of the device(s) depends on the type of aircraft and its equipment
and therefore only general information can be given in this section.
Installation Switch (INS_SW)
It is necessary to install a switch to get access to the RT6512 installation parameters.
•
Access to RT6512 installation parameters is only possible when RT6512 /SERV_EN line
is connected to ground.
o
RT6512, connector P1/28 → turnkey (INS_SW) → GND.
•
Setting of RT6512 installation parameters are available only when installation
switch* (INS_SW) is closed.
•
Otherwise settings of RCU6512 installation parameters only will be possible.
* For details see "Figure 9: RT6512 with RCU6512 as Primary Controller", page 32).
Controller
RCU6512
VHF COM 1
RT6512
RS422 Interface