Becker P5-B01 Скачать руководство пользователя страница 4

Safety instructions

The following safety instructions and warnings are intended to avert hazards and to prevent property damage and personal injury.

Instructions for the user

General information

All work, including maintenance and cleaning, on electrical installations as well as other system parts must always be performed
by authorised specialists, in particular qualified electricians.

Children from the age of 8 years and persons with reduced physical, sensory or mental capabilities or lack of experience and/or
knowledge may use these devices, provided they are supervised or have been instructed in the safe use of the device, and have
understood the hazards involved. Children must not play with the device.

Systems have to be checked regularly by authorised specialists for wear and damage.

Always put damaged systems out of operation immediately until they are repaired by an authorised specialist.

Do not operate equipment if people or objects are within the danger zone.

Observe the danger zone of the equipment during operation.

Stop and disconnect the equipment from the mains power supply when maintenance and cleaning is being performed either on
the system itself or in the immediate vicinity of it.

Ensure that there is adequate clearance (at least 40 cm) between moving parts and adjacent objects.

Caution

Safety instructions for avoiding serious injuries.

Crushing or shearing points must be avoided or protected.

Instructions for installation and commissioning

General information

Observe the safety instructions in EN 60335-2-97. Please note that this list of safety instructions is not exhaustive, since it would
be impossible for the standard to include all sources of danger. For example, the design of the operated product, the way the
drive works in the situation it is installed in or even the way the end product is mounted in the end user’s place of use cannot be
taken into consideration by the drive manufacturer. 
If any questions or uncertainties regarding the safety instructions contained in the standard arise, please contact the manufac-
turer of the part or end product in question.

All applicable standards and regulations for electrical installation must be complied with.

All work, including maintenance and cleaning, on electrical installations as well as other system parts must always be performed
by authorised specialists, in particular qualified electricians.

Only use spare parts, tools and accessory devices which have been approved by the drive manufacturer. 
Unapproved third-party products or modifications to the system and its accessories represent a risk to your safety and the
safety of others. This means that the use of unapproved third-party products, or modifications which have not been agreed with
or approved by us, are prohibited. We do not accept liability for damage or injury arising from such actions.

Position control devices within sight of the driven product, but away from moving parts, at a height of over 1.5 m.

Permanently mounted control devices must be positioned where they can be seen.

Rated torque and duty cycle must be suitable for the requirements of the driven product. 
Technical data – rated torque and service life can be found on the type plate of the tubular drive.

Moving parts of drives must be installed at a height of over 2.5 m above floor level or any other surface from which access to the
drive is gained.

To ensure safe operation of the system after commissioning, the limit positions must be correctly set/programmed in.

Drives with a H05VV-F connecting cable may only be used indoors.

Drives with a H05RR-F, S05RN-F or 05RN-F connecting cable may be used both indoors and outdoors.

To connect the drive to the driven part, solely mechanical accessory components made by the drive manufacturer from the cur-
rent product catalogue may be used. The components must be installed in accordance with the manufacturer's instructions.

If the drive is used for shading solutions in a specially marked area (e.g. escape routes, hazard zones, safety areas), compliance
with all applicable regulations and standards must be ensured.

Caution

Safety instructions for avoiding serious injuries.

When electrical or electronic equipment and units are operated, certain components, e.g., the power supply

unit, are live. Physical injuries or damage to property can result in the event of unauthorised interventions or

failure to heed warnings.

Be careful when touching the tubular drive, as it heats up during operation for technological reasons.

Before installation, shut down all lines and control devices that are not essential for operation.

4

Содержание P5-B01

Страница 1: ...r drive with integrated radio transceiver Important information for Fitters Electricians Users Please forward accordingly These instructions must be kept safe for future reference Becker Antriebe GmbH Friedrich Ebert Straße 2 4 35764 Sinn Germany www becker antriebe com ...

Страница 2: ...Undoing the mounting pin 9 Drive adapter for obstacle detection 9 Assembling the drive adapter with drive adapter safety catch 9 Assembling the drive adapter with screw connection 9 Securing the drive against axial displacement 10 Fixing the drive adapter to the barrel dia 35 and dia 45 10 Mounting the drive in the tube 10 Preparation for Commissioning 11 Checking that the running direction is cor...

Страница 3: ... Anti freeze mechanism in the upper limit position can be enabled Considerably lower stop load and thus considerably lower shading solution load Smooth operation of the system and the drive increases the service life For plug in connecting cable Fly screen protection function Please observe these Assembly and Operating Instructions when installing and setting the equipment The date of manufacture ...

Страница 4: ...ied with All work including maintenance and cleaning on electrical installations as well as other system parts must always be performed by authorised specialists in particular qualified electricians Only use spare parts tools and accessory devices which have been approved by the drive manufacturer Unapproved third party products or modifications to the system and its accessories represent a risk t...

Страница 5: ... e g Zurfluh Feller Simu GAH Alberts and Deprat These are detected automatically If the springs or the top lath are screwed or riveted to the barrel a point must be set in the lower limit position For sun protection applications please use only the types of tubular drive designed for this purpose This type of tubular drive is designed for use in single systems one drive per barrel The tubular driv...

Страница 6: ...e dead connecting cable into the drive head until the locating lug clicks into place in the drive If necessary use a suitable flathead screwdriver to assist with insertion Set the screwdriver into one of the two plug grooves provided for this purpose Check that the cable is properly engaged 1 locating lug 6 ...

Страница 7: ...the connecting cable must be disconnected On drives with a diameter Ø35 insert a suitable flathead screwdriver between the locating lug and the snap in pin so that the snap in pin releases the locating lug from the plug Now you can pull out the connecting cable along with the flathead screwdriver Ø35 A A snap in pin 7 ...

Страница 8: ... drive torque plus weight of the shading solution Caution Electrical connections may only be carried out by a qualified electrician Prior to assembly the power supply must be disconnected and secured Please give the enclosed connection information to the responsible elec trical contractor These drives cannot be operated with conventional switching elements switches timers and the like If you want ...

Страница 9: ...he tab washer 1 upwards and pull out the mounting pin 2 Drive adapter for obstacle detection If you wish to use the obstacle detection function you must use the drive adapter for obstacle detection Assembling the drive adapter with drive adapter safety catch Put the drive adapter 1 onto the drive shaft of the tubular drive You can see which way to insert the safety catch 2 from its shape When inse...

Страница 10: ...tube or drop it into the barrel The curtain can only be secured using springs or anti lifting devices Mounting the drive in the tube For profile tubes In the case of some drive adapters tolerances of the groove widths in different bar rels can be offset by rotating the drive adapter into a different groove recess These groove recesses have different sizes and allow the drive to fit exactly For rou...

Страница 11: ...tracks When first installing using springs and adjusting the limit position to lower stop the barrel in the lower limit position turns approx 1 4 of a turn further than usual In doing so the tubular drive is able to detect the use of anti lifting devices or springs automatically The tubular drive switches off automatically Limit position status indicator A brief stopping and restarting indicates t...

Страница 12: ...the appropriate description in the instructions for the B Tronic transmit ter Checking that the running direction is correct It is only possible to change the direction of rotation if no limit position has been set Press the UP or DOWN button The shading solution runs in the desired direction Direction switch is OK If the shading solution runs in the wrong direction the running direction must be s...

Страница 13: ... ring Use of the drive s obstacle detection system as personal protection is not permitted It has been designed ex clusively to protect the roller shutters or sun protection system from being damaged If the drive is correctly installed it switches off when it detects obstructions or shutter faults and reverses a short way in the oppos ite direction The following are detected In the DOWN direction ...

Страница 14: ... Emission sound pressure level dB A 70 Technical data dia 45 Model R8 B01 R12 B01 R20 B01 R30 B01 R40 B01 Type R8 17C PROF KNX R12 17C PROF KNX R20 17C PROF KNX R30 17C PROF KNX R40 17C PROF KNX Rated torque Nm 8 12 20 30 40 Output speed rpm 17 17 17 17 17 Limit switch range 64 revolutions Supply voltage 230 V AC 50 Hz Connected load W 100 110 160 205 260 Rated current consumption A 0 45 0 5 0 75 ...

Страница 15: ...ion Tubular drive has detected an increase in load Briefly run the curtain in the opposite dir ection then continue in the desired direc tion Tubular drive is overloaded Use a higher torque tubular drive Tubular drive does not operate at the set switching time Tubular drive is in manual mode Use a B Tronic transmitter to switch the tubular drive into automatic mode Set switching times change Frequ...

Страница 16: ...Sample wiring diagram N L PE Electronics Black Brown Blue Green yellow 16 ...

Страница 17: ...Declaration of Conformity 17 ...

Страница 18: ...18 ...

Страница 19: ...19 ...

Страница 20: ...2010 300 564 0 13 05 2015 ...

Отзывы: