Becker P5-B01 Скачать руководство пользователя страница 11

After programming the transmitter, position the barrel so that the roller shutter curtain can be mounted with springs or fit the anti-
lifting device in accordance with the manufacturer's instructions.

When using springs/anti-lifting devices, we recommend you use at least three; for longer tubes, use three

springs/anti-lifting devices per meter of barrel. 

Lay the connecting cable

Lay the connecting cable up to the tubular drive, and fix The connecting cable and
any antennae must not project into the winding chamber. Cover any sharp edges.

Preparation for Commissioning

The tubular drive can be operated with any suitable KNX transmitter
The commissioning (e.g. setting the limit positions etc.) and later configurations are, however, only possible with a B-Tronic trans-
mitter.

The running direction must be correct. When setting the limit positions, the tubular drive runs with the limit po-

sition status indicator. The upper limit position must always be set first. When setting the upper limit position,

ensure that the roller shutter curtain is not pulled out of the guide tracks.

When first installing, using springs and adjusting the limit position ‘...to lower stop’, the barrel in the lower limit

position turns approx. 1/4 of a turn further than usual. In doing so, the tubular drive is able to detect the use of

anti-lifting devices or springs automatically. The tubular drive switches off automatically.

Limit position status indicator

A brief stopping and restarting indicates that no limit position has been set in that direction of movement.

Completion of installation following automatic setting of limit positions

The drive saves the limit position permanently once the upper limit position is reached 3 times in succession. Installation is then
complete. If the limit position is set above a point, this is stored permanently.

Explanation of symbols

1 = direction switch

2 = radio switch

N

1

2

1

2

4

3

4

230V AC / 50 Hz

L1

PE

Connecting the tubular drive

Connect the tubular drive to the power supply.

1 = blue

3 = black

2 = brown

4 = green-yellow

If several tubular drives are to be connected in parallel, you can deactivate the programming mode on one tu-

bular drive by switching the radio switch to the outside position after turning the power on. If the radio switch is

already in this position, switch it to the inside and back to the outside position.

11

Содержание P5-B01

Страница 1: ...r drive with integrated radio transceiver Important information for Fitters Electricians Users Please forward accordingly These instructions must be kept safe for future reference Becker Antriebe GmbH Friedrich Ebert Straße 2 4 35764 Sinn Germany www becker antriebe com ...

Страница 2: ...Undoing the mounting pin 9 Drive adapter for obstacle detection 9 Assembling the drive adapter with drive adapter safety catch 9 Assembling the drive adapter with screw connection 9 Securing the drive against axial displacement 10 Fixing the drive adapter to the barrel dia 35 and dia 45 10 Mounting the drive in the tube 10 Preparation for Commissioning 11 Checking that the running direction is cor...

Страница 3: ... Anti freeze mechanism in the upper limit position can be enabled Considerably lower stop load and thus considerably lower shading solution load Smooth operation of the system and the drive increases the service life For plug in connecting cable Fly screen protection function Please observe these Assembly and Operating Instructions when installing and setting the equipment The date of manufacture ...

Страница 4: ...ied with All work including maintenance and cleaning on electrical installations as well as other system parts must always be performed by authorised specialists in particular qualified electricians Only use spare parts tools and accessory devices which have been approved by the drive manufacturer Unapproved third party products or modifications to the system and its accessories represent a risk t...

Страница 5: ... e g Zurfluh Feller Simu GAH Alberts and Deprat These are detected automatically If the springs or the top lath are screwed or riveted to the barrel a point must be set in the lower limit position For sun protection applications please use only the types of tubular drive designed for this purpose This type of tubular drive is designed for use in single systems one drive per barrel The tubular driv...

Страница 6: ...e dead connecting cable into the drive head until the locating lug clicks into place in the drive If necessary use a suitable flathead screwdriver to assist with insertion Set the screwdriver into one of the two plug grooves provided for this purpose Check that the cable is properly engaged 1 locating lug 6 ...

Страница 7: ...the connecting cable must be disconnected On drives with a diameter Ø35 insert a suitable flathead screwdriver between the locating lug and the snap in pin so that the snap in pin releases the locating lug from the plug Now you can pull out the connecting cable along with the flathead screwdriver Ø35 A A snap in pin 7 ...

Страница 8: ... drive torque plus weight of the shading solution Caution Electrical connections may only be carried out by a qualified electrician Prior to assembly the power supply must be disconnected and secured Please give the enclosed connection information to the responsible elec trical contractor These drives cannot be operated with conventional switching elements switches timers and the like If you want ...

Страница 9: ...he tab washer 1 upwards and pull out the mounting pin 2 Drive adapter for obstacle detection If you wish to use the obstacle detection function you must use the drive adapter for obstacle detection Assembling the drive adapter with drive adapter safety catch Put the drive adapter 1 onto the drive shaft of the tubular drive You can see which way to insert the safety catch 2 from its shape When inse...

Страница 10: ...tube or drop it into the barrel The curtain can only be secured using springs or anti lifting devices Mounting the drive in the tube For profile tubes In the case of some drive adapters tolerances of the groove widths in different bar rels can be offset by rotating the drive adapter into a different groove recess These groove recesses have different sizes and allow the drive to fit exactly For rou...

Страница 11: ...tracks When first installing using springs and adjusting the limit position to lower stop the barrel in the lower limit position turns approx 1 4 of a turn further than usual In doing so the tubular drive is able to detect the use of anti lifting devices or springs automatically The tubular drive switches off automatically Limit position status indicator A brief stopping and restarting indicates t...

Страница 12: ...the appropriate description in the instructions for the B Tronic transmit ter Checking that the running direction is correct It is only possible to change the direction of rotation if no limit position has been set Press the UP or DOWN button The shading solution runs in the desired direction Direction switch is OK If the shading solution runs in the wrong direction the running direction must be s...

Страница 13: ... ring Use of the drive s obstacle detection system as personal protection is not permitted It has been designed ex clusively to protect the roller shutters or sun protection system from being damaged If the drive is correctly installed it switches off when it detects obstructions or shutter faults and reverses a short way in the oppos ite direction The following are detected In the DOWN direction ...

Страница 14: ... Emission sound pressure level dB A 70 Technical data dia 45 Model R8 B01 R12 B01 R20 B01 R30 B01 R40 B01 Type R8 17C PROF KNX R12 17C PROF KNX R20 17C PROF KNX R30 17C PROF KNX R40 17C PROF KNX Rated torque Nm 8 12 20 30 40 Output speed rpm 17 17 17 17 17 Limit switch range 64 revolutions Supply voltage 230 V AC 50 Hz Connected load W 100 110 160 205 260 Rated current consumption A 0 45 0 5 0 75 ...

Страница 15: ...ion Tubular drive has detected an increase in load Briefly run the curtain in the opposite dir ection then continue in the desired direc tion Tubular drive is overloaded Use a higher torque tubular drive Tubular drive does not operate at the set switching time Tubular drive is in manual mode Use a B Tronic transmitter to switch the tubular drive into automatic mode Set switching times change Frequ...

Страница 16: ...Sample wiring diagram N L PE Electronics Black Brown Blue Green yellow 16 ...

Страница 17: ...Declaration of Conformity 17 ...

Страница 18: ...18 ...

Страница 19: ...19 ...

Страница 20: ...2010 300 564 0 13 05 2015 ...

Отзывы: