5
-
+
-
+
All bus lines
YCYM 2×2×0.8 mm
KNX Bus
KNX Bus
Powerline on-site
230 V AC/50 Hz/16 A
3x1.5 mm²
N
PE
L
N
PE
L
to other
components
L
KNX
-
KNX+
X5
X6
X1
N
I −
I +
I −
I +
Lout
X2
4
3
1
2
4
3
1
2
4
3
1
2
4
3
1
2
BL
BN
BK
GY
GNYE
BL
BN
BK
GY
GNYE
BL
BN
BK
GY
GNYE
Junction box
M
SMI
I+
PE
L
N
I-
M
SMI
I+
PE
L
N
I-
M
SMI
I+
PE
L
N
I-
BL
BN
BK
GY
GNYE
BL BN
BK
GY
GNYE
M
SMI
I+
PE
L
N
I-
Motor 1
Motor 2
Motor 15
Motor 16
5 × 1.5 mm
2
All motor lines
H05RR-F 5 G 0.75 BK
Example:
Connection of SMI motors
Maximum of 16 motors
Total power maximum 3600 VA for the
power-saving relay of the SMI drives.
Connection when using motor lines
H05RR-F 5 G 0.75 with two black wires:
I+ Black 1 (between BL and GNYE)
I- Black 2 (between BN and GNYE)
X6
: Auxiliary voltage connection
Note:
Be mindful of voltage drops across the
length of the line when dimensioning the
cable cross-sections!
Fig. 5
Connection example