Display Contents
Description
The “SCAN HOLD_TIME” is adjustable within the range of 1 to
60 seconds by turning the “ROTARY ENCODER”.
Note:
1. For normal operation it is recommended to leave the setting
at 1.
2. The default factory setting is 1.
The sidetone attenuation “SIDETONE ATT” is adjustable within
the range 0…12 dB by turning the “ROTARY ENCODER”.
The attenuation relates to the intercom volume.
0 dB = sidetone as loud as intercom signal.
12 dB = sidetone signal 12 dB less than the intercom signal.
Example; If the intercom volume is set to a very low value, then
the sidetone volume will be reduced in relation to the intercom
volume, irrespective of the sidetone value.
The “SIDETONE ATT” parameter is an additional attenuation of
the sidetone signal in transmit mode.
Note:
This Menu is available on primary controller only.
The GT6201 Transceiver provides two databases to store up to
99 VHF frequencies identified by channel numbers (CH01 to
CH99).
Both data bases, the “User Channels Database” and “Last
Channels Database” can be erased.
To erase the data bases;
1. Select “YES” via the “ROTARY ENCODER”
2. Press the “STO” push-button to confirm the selection.
Note:
Menu available on primary controller only
The GT6201 provides a third database, “FRQUENCY LABELS
DATABASE”, containing 99 text labels of max 10 characters
each. A text label can be assigned to any of the channels (CH01
to CH99), the Labels are stored manually.
The “LABELS DATABASE” can be erased.
To Erase the data base;
1. Select “YES” via the “ROTARY ENCODER”
2. Press the “STO” push-button to confirm the selection.
Note:
Menu available on primary controller only
This page automatically stores and displays information from all
failures that occur during operation of the GT6201.
Used for trouble shooting and failure isolation.
Note:
1. The display can only show 4 (GT6201) monitored failures
types (more are available).