22
Operating Instructions
Explanations
Manual/Automatic sliding switch
When the sliding switch is set to manual mode “ “, only manual control com-
mands and alarm signals are executed (e.g. by pressing the RETRACT, STOP,
EXTEND button).
When the sliding switch is set to “AUTO”, automatic control commands and auto-
matic radio commands are executed (control signals via group control inputs)
Control light
If the control light is illuminated, this indicates an alarm signal. An alarm signal
is a continuous switching signal at the group or individual control inputs which
lasts for more than 5 seconds.
The ALARM SIGNAL function can be switched on/off using the encoding switch 1.
Group control
Group control is control of several drives at the same time.
Programming button
Press the programming button to set the receiver to programming mode for 3
minutes. The master transmitter can now be programmed.
RESET button
Press the RESET button (with a ballpoint pen or similar object) to delete the
intermediate position and the fabric tensioning position.
Intermediate position
The intermediate position lies between the upper and lower limits of the relative
system and can be selected as desired. The relative system is adjusted into this
position from the upper position after programming.
Press the EXTEND button
twice
in quick succession.
Fabric Tensioning
The fabric tensioning position is a freely selectable awning position between the
extended and retracted end limit. Use this function to tension the fabric of your
sun protection system.
Press the RETRACT button
twice
in quick succession.
Содержание Centronic UnitControl UCS520
Страница 9: ...FR GB DE NL 9 Anzeigen und Tastenerklärung ...
Страница 21: ...FR GB DE NL 21 Explanation of displays and buttons ...
Страница 33: ...FR GB DE NL 33 Explication des textes d affichage et des touches ...
Страница 45: ...FR GB DE NL 45 Verklaring van displays en toetsen ...
Страница 52: ...4031 630 011 0a 08 05 DE GB FR NL 309156 01 Becker Antriebe GmbH 35764 Sinn Germany ...