Aug 2011, V 1.0
BECCA INC.
Instruction Manual S300A Spray Gun Cleaner
16
SOLVENTWASH™
Filtration Recycling System (Optional)
Filter Replacement Instructions
1.
Important!
Before removing the Filter Housing:
Lift the line out of the container
Then allow the pump to continue to run with the Wash Basin or Flow Brush in the
“On” position.
Run the unit to remove some of the solvent from the Housings (3-
5”).
2. Turn the Filter Housing with the provided Wrench. If stuck, lightly tap housing with a
rubber mallet to break the seal. Care should be taken so not to crack the housing.
3. Make sure to replace both filters and place them in the correct position (75 Micron-
first to see the solvent and 25 Micron
–
last to see the solvent before being used)
4. Make sure to replace both seals in the Ficlter Housings. (Note: The old seal will not
work after the Filter Housing has been removed)
5. Make sure Filter is located in the Guide located on the threaded top before spinning
housing. Tighten The Filter Housings to a snug position. (Do Not Over Tighten!!)
6.
When Running the Spray Gun Cleaner it will take a few minutes to fill the Filter
Housing before flowing out of the selected function.
7. Used Filters (are Hazardous until proven different) should be allowed to dry and
then dispose per local jurisdiction requirements.
You are ready to use your system!