background image

 

 

figures whether pre-heating settings are set or not 

See following Fig.7-8

 

ON

         

O F F

 

Fig.7

Pre-heat On

                           

8

Pre-heat Off

 

Pre-heating is set when the spa is in the 

“Power off” status and the LCD display shows 

---

 

 
 

1

         

                           

                      Set preheating 

 

                                                     

 

2

                                                                               

Time setting for Preheating

 

                                                     

 

 

                                                     

 

3

         

                                                                     

Continual time of preheating

 

                                                     

 

 

4

         

                           

                       

Preset temperature

 

 
 

5

         

 

            Finished 
 
 
 
 
 
 
 
 

Содержание SPA-520

Страница 1: ...1 HOT TUB Model SPA 520 OPERATING INSTRUCTION...

Страница 2: ...ry Lock Surfing pump 1 On off SET Radio channel read Close view pump 2 On off Lasting Circulation Cleaning On off Surfing pump3 circulation pump On off Set Circulation Cleaning Time Heating On off Set...

Страница 3: ...re If there is a problem with the circuit board the controller will display the code E1 When the radio frequency is displayed as it indicates that the spa is in power off model and pre heating and cir...

Страница 4: ...cleaning on When setting the Circulation cleaning the display must be in the Power off status and the LCD display 1 Press to enter Circulation cleaning setting mode and the LCD shows and flashes and t...

Страница 5: ...d 55 minutes When you have completed this procedure continue to the next setting 4 If all settings have been correctly set Press for confirmation the system will quit this mode automatically press key...

Страница 6: ...ee following Fig 7 8 ON OFF Fig 7 Pre heat On 8 Pre heat Off Pre heating is set when the spa is in the Power off status and the LCD display shows 1 Set preheating 2 Time setting for Preheating 3 Conti...

Страница 7: ...Press SET VOL again It will show SET on the LCD panel Press button to change the setting temperature The range of temperature setting is 15 45 5 When everything is set correctly press the to confirm...

Страница 8: ...shows the countdown time All the surfing pumps and blower will work for 30 seconds at every 30 minutes The Ozone works at every 15 minutes During the preheating the Circulation cleaning will be turne...

Страница 9: ...annel LCD will display Press the key MEM could memorize the present radio frequency Pressing the key MEM continually will memorize the present radio frequency in different channel The channel of max i...

Страница 10: ...off pressing the key can change the mode of Fahrenheit Celsius degree 17 When there is no water in the spa All water pumps and heating system can not start up However the corresponding signals will f...

Страница 11: ...d be supplied through a residual current device RCD having a rated residual operating current not exceeding 30 mA The floor has to be capable of supporting the expected load An adequate drainage syste...

Страница 12: ...nge a new ozonater 2 change a fuse 3 check if the cable of the main power is connected with the main box or not Displaied E1 FF in control panel 1 temperature detector be cut off or shortcirculate 2 p...