background image

1

2

3

4

5

6

7

8

MAGIC SWITCH: MS21H

75.5737.12 MS21H 20201014 

 

Page 1 of 4

1.  faceplate
2.  mounting holes
3.  set screws
4.  backplate
5.  NEMA 4 enclosure
6.  wire harness
7.  DIP-switches
8.  potentiometer

PRODUCT FAMILY

6” ROUND STYLES

4.75” SQUARE STYLES

10MS21HR

text only

10MS21HS

text only

10MS21HRLL

logo only

10MS21HSLL

logo only

10MS21HR1

text & logo

10MS21HS1

text & logo

Technology

capacitive sensing

Detection Mode

proximity

Supply Voltage

12 – 24 VAC/VDC

Current Consumption

37 mA (typical)

Temperature Range

-20 – 120 °F

Enclosure Rating

NEMA 4

Sensing Zone

0 – 4”

Sensing Zone is dependent upon size (area) of object, orientation of object, speed of 

object, and environmental conditions.

Relay

1-Form A Solid State Relay
0.4A 60 VAC/VDC (max)

Dimensions (0verall)

6” Round:

4.75” Square:

7” (diameter) × 0.5” (D)
5.75” (H) × 5.75” (W) × 0.5” (D)

Wire Harness Length

6 inches (5-conductor)

A 5-conductor wire is needed between the sensor and the door control.

Material

stainless steel (faceplate)
clear polycarbonate (mounting ring, backplate, enclosure)

Specifications are subject to change without prior notice.

All values measured in specific conditions.

TECHNICAL SPECIFICATIONS

ENGLISH

Hardwired, Stainless Steel, Touchless, 

Activation Sensor

Visit website for 

available languages of 

this document.

DESCRIPTION

Содержание MAGIC SWITCH MS21H

Страница 1: ...NEMA 4 Sensing Zone 0 4 Sensing Zone is dependent upon size area of object orientation of object speed of object and environmental conditions Relay 1 Form A Solid State Relay 0 4A 60 VAC VDC max Dimensions 0verall 6 Round 4 75 Square 7 diameter 0 5 D 5 75 H 5 75 W 0 5 D Wire Harness Length 6 inches 5 conductor A 5 conductor wire is needed between the sensor and the door control Material stainless ...

Страница 2: ...or powering each MS21 Red must be connected to power and black connected to power It is recommended that 300 V low voltage cabling shielded wire be used during installation It is recommended that the MS21 cabling have a distance of 6 inches around power lines 120 VAC VDC or higher If using a wire harness with more than 5 conductors all extra conductors must be wired at both ends to Earth Ground IN...

Страница 3: ...seconds to complete the initialization sequence once powered Wire nut harness wires and isolation module wires together and then connect the isolation module wires to the door control using the chart or visual representation below NOTE From isolation module to ACT use either green NO OR yellow NC A SENSING ZONE potentiometer COUNTERCLOCKWISE decrease 0 minimum CLOCKWISE increase 4 maximum 1 B AUDI...

Страница 4: ...ed Questions Sensor erratically detecting or falsely activating Not properly grounded Verify continuity between sensor ground and earth ground See Application Note for details Unstable power supply Ensure the BEA isolation module polarity sensitive is being used with each MS21 Electrical noise within sensing zone Reduce sensing zone potentiometer counterclockwise Non stationary object within detec...

Отзывы: