3

A

B C

2

75.5737.12 MS21H 20201014 

 

Page 3 of 4

GREEN
YELLOW

RED
BLACK
WHITE

RED

BLACK

WHITE

GREEN

BLUE

Installer Provided 

Wire Harness

ISOLATION 

MODULE

RED

BLACK

WHITE

BLUE

WIRE NUT

NO

COM

− POWER

+ POWER

NC

EAR

TH GROUND

GREEN / YELLOW

GREEN

DOOR HEADER

Isolation Module

Signal

Harness Wire

Isolation Module Wire

Door Control Terminal

To Door Control

(6-wire side)

AC/DC +

-

Red

AC/DC +

AC/DC -

-

Black

AC/DC -

COM

-

White

ACT COM

NO

-

Green

ACT NO

NC

-

Yellow

ACT NC

Earth Ground

-

Green / Yellow

Earth Ground

To MS21

(5-wire side)

COM

White

White

-

NO

Green

Green

-

AC/DC

Red

Red

-

AC/DC

Black

Black

-

Earth Ground

Blue

Blue

-

It will take approximately 10 seconds to complete the initialization sequence once powered. 

Wire-nut harness wires and isolation module wires together and then connect the isolation 
module wires to the door control using the chart or visual representation below.

NOTE: 

 From isolation module to ACT, use either green (NO) OR yellow (NC).

(A) SENSING ZONE 

 potentiometer

COUNTERCLOCKWISE – decrease (0’’ minimum)

CLOCKWISE – increase (4’’ maximum)

1

(B) AUDIBLE ALERT 

– DIP-switch 1 (left)

ON – audible alert pulsed for 0.5 seconds during detection

OFF – audible alert off

(C) LED 

– DIP-switch 2 (right)

ON – LED on at rest, pulsed off for 0.5 seconds during detection

OFF – LED off at rest, pulsed on for 0.5 seconds during detection

SETTINGS & ADJUSTMENTS

NOTES:

1.  Maximum Sensing Zone will vary depending on size (area), orientation, and speed of object as well as environmental conditions.

WIRING (cont.)

Содержание MAGIC SWITCH MS21H

Страница 1: ...NEMA 4 Sensing Zone 0 4 Sensing Zone is dependent upon size area of object orientation of object speed of object and environmental conditions Relay 1 Form A Solid State Relay 0 4A 60 VAC VDC max Dimensions 0verall 6 Round 4 75 Square 7 diameter 0 5 D 5 75 H 5 75 W 0 5 D Wire Harness Length 6 inches 5 conductor A 5 conductor wire is needed between the sensor and the door control Material stainless ...

Страница 2: ...or powering each MS21 Red must be connected to power and black connected to power It is recommended that 300 V low voltage cabling shielded wire be used during installation It is recommended that the MS21 cabling have a distance of 6 inches around power lines 120 VAC VDC or higher If using a wire harness with more than 5 conductors all extra conductors must be wired at both ends to Earth Ground IN...

Страница 3: ...seconds to complete the initialization sequence once powered Wire nut harness wires and isolation module wires together and then connect the isolation module wires to the door control using the chart or visual representation below NOTE From isolation module to ACT use either green NO OR yellow NC A SENSING ZONE potentiometer COUNTERCLOCKWISE decrease 0 minimum CLOCKWISE increase 4 maximum 1 B AUDI...

Страница 4: ...ed Questions Sensor erratically detecting or falsely activating Not properly grounded Verify continuity between sensor ground and earth ground See Application Note for details Unstable power supply Ensure the BEA isolation module polarity sensitive is being used with each MS21 Electrical noise within sensing zone Reduce sensing zone potentiometer counterclockwise Non stationary object within detec...

Отзывы: