TROUBLESHOOTING

ORANGE LED flashes 1 x.

ORANGE LED flashes 2 x.

ORANGE LED flashes 4 x.

ORANGE LED is on.

RED LED flashes 
quickly after an 
assisted setup.

RED LED lights up 
sporadically.

GREEN LED lights up 
sporadically.

The LED and the LCD-
display are off.

The reaction of the door 

does not correspond to 

the LED-signal.

The sensor signals 
an internal fault.

The power supply is too 
low or too high.

The sensor receives 
not enough IR-energy.

The sensor encounters 
a memory problem.

The sensor vibrates.

The sensor sees the door 
during the assisted setup.

The sensor sees the door.

The sensor is disturbed 
by external conditions.

The sensor is disturbed by 
rain and/or leaves.

The sensor vibrates.

Ghosting created by door 
movement.

The sensor sees the door 
or other moving objects.

Check power supply 

(in the diagnostics menu of the LCD).

Check wiring.

Cut and restore power supply.  
If orange LED lights up again, replace sensor.

Check output configuration setting.
Check wiring.

Check if the sensor is fastened firmly.
Check position of cable and cover.

Increase the IR-immunity filter to value 3.
Select presetting 2 or 3.

Select presetting 2 or 3. 
Increase radar-immunity filter.

Change radar field angle.

Check if the sensor and door cover is fastened firmly.
Check position of cable and cover.

Change radar field size or angle.

Remove the objects if possible.

Launch an assisted setup and adjust the IR angle.

Replace sensor.

ORANGE LED flashes 6 x.

ORANGE LED flashes 7 x.

Faulty radar sensor output

Replace sensor.

The internal test of the 

radar is disturbed.

Change radar field angle or antenna.
Launch a quick setup.
If orange LED flashes again, replace sensor.

Check wiring.

ORANGE LED flashes 5 x.

The sensor receives 
too much IR-energy.

ORANGE LED flashes 8 x.

IR power emitter is faulty.

Replace sensor.

ORANGE LED flashes 9 x.

Internal reference of the 

radar is faulty.

Replace sensor.

The LCD or remote 

control does not react.

Enter the right password. If you forgot the code, cut 
and restore the power supply to access the sensor 
without entering a password during 1 minute.

The sensor is protected by a 

password.

The sensor is disturbed by 
external elements.

Eliminate the cause of disturbance (lamps, rain cover, 
door controller housing properly grounded).

Move the IR-curtains away from the door.
Install the sensor as close to the door as possible. 
If needed, use a bracket accessory.
Launch a new assisted setup.

Decrease the angle of the IR-curtains.
Increase the IR-immunity filter (values >2.8 m).
Deactivate 1 curtain.

Slightly increase the angle of the IR-curtains.
Decrease the IR-immunity filter (values 1-3 <2.8 m).

Содержание IXIO-DP3

Страница 1: ... knob Opening safety sensor for automatic sliding doors User s Guide for product version 0400 and higher See product label for serial number ACCESSORIES BA Bracket accessory CA Ceiling accessory CDA Curved door accessory according to EN 16005 and DIN 18650 including emergency exits RA Rain accessory Download the BEA DECODER app for a quick overview of settings Retrofit interface Door bell interfac...

Страница 2: ...L FUNCTIONING FACTORY VALUE VS SAVED VALUE NAVIGATING IN MENUS Scroll menu items Push to enter the LCD menu new value is displayed more values are displayed current value is displayed displayed value saved value displayed value factory value Opening impulse Safety 6 6 Enter password if necessary Not during the first minute after power on of the sensor CHANGING A ZIP CODE Password X X X X ZIP code ...

Страница 3: ...of the detection field varies according to the mounting height of the sensor In emergency exits the full door width must be covered from 15 to 45 default 30 from 15 to 15 default 0 OR YE BK WH BK NO normally open NC normally closed ENGLISH IXIO DP3 INSTALLATION GUIDE for emergency exits for emergency exits GREEN BROWN YELLOW WHITE PINK GREY YE BK WH BK POWER SUPPLY POWER SUPPLY OPENING INPUT SAFET...

Страница 4: ...utside door sensor should always be smaller than 20 cm The distance to the door leaf depends therefore on the thickness of the door leaf The size of the detection field varies according to the mounting height and the settings of the sensor The full door width must be covered OR STANDARD standard in and outdoor installations CRITICAL ENVIRONMENT critical installations due to surroundings or weather...

Страница 5: ...ence factory values for radar immunity IR immunity IR number and redirection small large bi uni uni AWAY low 0 5 s 1 s 2 s 3 s 4 s 5 s 6 s 7 s 8 s 9 s uni PRM bi auto uni auto PRM auto PRM for persons with reduced mobility AWAY unidirectional motion away from sensor auto automatic adaptation of field size small shops service mode motion 15 s 30 s 1 min 2 min 5 min 10 min motion motion or presence ...

Страница 6: ...ease radar immunity filter Change radar field angle Check if the sensor and door cover is fastened firmly Check position of cable and cover Change radar field size or angle Remove the objects if possible Launch an assisted setup and adjust the IR angle Replace sensor ORANGE LED flashes 6 x ORANGE LED flashes 7 x Faulty radar sensor output Replace sensor The internal test of the radar is disturbed ...

Страница 7: ...e for carrying out a risk assessment and installing the sensor and the door system in compliance with applicable national and international regulations and standards on door safety The manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor Only trained and qualified personnel may install and setup the sensor The warranty is inva...

Страница 8: ...500 µs Duty cycle max 50 Output Pulse polarity negative Level Standby Pulse from V to ground Detection V Supply Topology op collector with 4 7 K to 3 3 V Max sink current 25 mA with external 1 K to 24 V EN 12978 EN ISO 13849 1 PL c CAT 2 under the condition that the door control system monitors the sensor at least once per door cycle IEC 61496 1 ESPE Type 2 EN 16005 Chapter 4 6 8 DIN 18650 1 Chapt...

Отзывы: