BEA IXIO-DP3 Скачать руководство пользователя страница 3

1

max. 5 cm

2

3

3

12-24 V DC

*

**

+

-

2.2 m

2.2 m

2.2 m

2.2 m

MOUNTING & WIRING

Fixation is compatible with the ACTIV8.

RELAY OUTPUT

FREQUENCY OUTPUT

CURRENT SOURCE OUTPUT

RADAR OUTPUT CONFIGURATION

RADAR OPENING IMPULSE FIELD

ANGLE

WIDTH

4 m x 2 m (wide)

2 m x 2.5 m (narrow)

field size: 9
immunity: 2

field size: 9
immunity: 2

field size: 9
immunity: 2

field size: 9
immunity: 2

The size of the detection field varies according to the mounting height of the sensor. 

In emergency exits the full door width must be covered.

from 15° to 45°, default 30 °

from -15° to 15°, default 0°

OR

YE/BK +

WH/BK  -

NO: normally open

NC: normally closed

ENGLISH

IXIO-DP3: INSTALLATION GUIDE

for emergency exits

for emergency exits

GREEN

BROWN

YELLOW

WHITE

PINK

GREY

YE/BK +

WH/BK  -

POWER

POWER SUPPLY -

OPENING INPUT

SAFETY OUTPUT

SAFETY INPUT

OPENING INPUT 

FOR EMEGENCY 

EXITS

*  Output status when sensor is operational 

**  Current source output for emergency exits

SE

NS

OR

Do not invert polarity!

Содержание IXIO-DP3

Страница 1: ... knob Opening safety sensor for automatic sliding doors User s Guide for product version 0400 and higher See product label for serial number ACCESSORIES BA Bracket accessory CA Ceiling accessory CDA Curved door accessory according to EN 16005 and DIN 18650 including emergency exits RA Rain accessory Download the BEA DECODER app for a quick overview of settings Retrofit interface Door bell interfac...

Страница 2: ...L FUNCTIONING FACTORY VALUE VS SAVED VALUE NAVIGATING IN MENUS Scroll menu items Push to enter the LCD menu new value is displayed more values are displayed current value is displayed displayed value saved value displayed value factory value Opening impulse Safety 6 6 Enter password if necessary Not during the first minute after power on of the sensor CHANGING A ZIP CODE Password X X X X ZIP code ...

Страница 3: ...of the detection field varies according to the mounting height of the sensor In emergency exits the full door width must be covered from 15 to 45 default 30 from 15 to 15 default 0 OR YE BK WH BK NO normally open NC normally closed ENGLISH IXIO DP3 INSTALLATION GUIDE for emergency exits for emergency exits GREEN BROWN YELLOW WHITE PINK GREY YE BK WH BK POWER SUPPLY POWER SUPPLY OPENING INPUT SAFET...

Страница 4: ...utside door sensor should always be smaller than 20 cm The distance to the door leaf depends therefore on the thickness of the door leaf The size of the detection field varies according to the mounting height and the settings of the sensor The full door width must be covered OR STANDARD standard in and outdoor installations CRITICAL ENVIRONMENT critical installations due to surroundings or weather...

Страница 5: ...ence factory values for radar immunity IR immunity IR number and redirection small large bi uni uni AWAY low 0 5 s 1 s 2 s 3 s 4 s 5 s 6 s 7 s 8 s 9 s uni PRM bi auto uni auto PRM auto PRM for persons with reduced mobility AWAY unidirectional motion away from sensor auto automatic adaptation of field size small shops service mode motion 15 s 30 s 1 min 2 min 5 min 10 min motion motion or presence ...

Страница 6: ...ease radar immunity filter Change radar field angle Check if the sensor and door cover is fastened firmly Check position of cable and cover Change radar field size or angle Remove the objects if possible Launch an assisted setup and adjust the IR angle Replace sensor ORANGE LED flashes 6 x ORANGE LED flashes 7 x Faulty radar sensor output Replace sensor The internal test of the radar is disturbed ...

Страница 7: ...e for carrying out a risk assessment and installing the sensor and the door system in compliance with applicable national and international regulations and standards on door safety The manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor Only trained and qualified personnel may install and setup the sensor The warranty is inva...

Страница 8: ...500 µs Duty cycle max 50 Output Pulse polarity negative Level Standby Pulse from V to ground Detection V Supply Topology op collector with 4 7 K to 3 3 V Max sink current 25 mA with external 1 K to 24 V EN 12978 EN ISO 13849 1 PL c CAT 2 under the condition that the door control system monitors the sensor at least once per door cycle IEC 61496 1 ESPE Type 2 EN 16005 Chapter 4 6 8 DIN 18650 1 Chapt...

Отзывы: