background image

Page 2 of 4  

75.5868.01 900 MHZ TOUCHLESS RETROFIT TRANSMITTER 20160412

• 

The device should not be used for purposes other than its intended use. All other uses cannot be 

guaranteed by the manufacturer of the sensor.  

• 

The installer of the door system is responsible for carrying out a risk assessment and installing the sensor and 

the door system in compliance with applicable national and international regulations and standards on door 

safety. 

• 

The manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate 

adjustments of the sensor.

1

2

3

Remove existing touch 
pushplate and disconnect two 
(2) existing in-wall wires from 
pushplate and door control 
activation.

Connect green and white 
wires to new touchless plate 
activation output.

Parallel red and black wires 
with two (2) existing in-wall 
wires and connect to new 
touchless plate power input.

INSTALLATION

4

5

6

Mount new touchless plate.

Connect two (2) existing in-
wall wires to power source in 
door control header.

Install 900 MHz wireless 
receiver in header (sold 
separately).

Shut off all power going to header before attempting any wiring procedures.

Maintain a clean & safe environment when working in public areas.

Constantly be aware of pedestrian traffic around the door area.

Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by 

the door.

ESD (electrostatic discharge): Circuit boards are vulnerable to damage by electrostatic discharge. Before handling 

any board ensure you dissipate your body’s ESD charge.

Always check placement of all wiring before powering up to ensure that moving door parts will not catch any wires 

and cause damage to equipment.

Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of installation.

DO NOT attempt any internal repair of the components. All repairs and/or component replacements must be per-

formed by BEA, Inc. Unauthorized disassembly or repair:

1.  May jeopardize personal safety and may expose one to the risk of electrical shock.

2.  May adversely affect the safe and reliable performance of the product resulting in a voided warranty.

PRECAUTIONS

Содержание 10TD900TR

Страница 1: ... Wires INTRODUCTION 1 3 2 For existing hard wired touch pushplates most often only two 2 wires are installed running within the wall from the pushplate to the door control for activation The 900 MHz Touchless Retrofit Transmitter allows an existing hard wired touch pushplate to be retrofitted with a new touchless plate that requires four 4 wires 2 wires for power and 2 wires for activation without...

Страница 2: ...door control header Install 900 MHz wireless receiver in header sold separately Shut off all power going to header before attempting any wiring procedures Maintain a clean safe environment when working in public areas Constantly be aware of pedestrian traffic around the door area Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the...

Страница 3: ...ransmitter and door control Receiver not programmed Setup transmitter Constant activation Something is moving in front of touchless plate Clear area around plate Transmitter connected to NC of touchless sensor Connect to NO Receiver and or touchless sensor set to Toggle Mode Set receiver and or touchless sensor to Pulse Mode SETUP 1 Learn transmitter and receiver1 NOTES 1 Refer to 900 MHz wireless...

Страница 4: ... Service 1 800 523 2462 General Tech Questions Tech_Services beainc com Tech Docs www beasensors com FCC ID 2ABWS 10TD900TR IC 4680A 10TD900TR MODEL 10TD900TR FCC IC This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference th...