18
19
Features
Operation
UNIT GROUNDING
Starting the Generator
FILLING OIL
MODEL
BE-12000ER
AC OUTPUT
Frequency
60Hz
Voltage
120/240V
Rated Power (W)
9500
Max. Power (W)
12000
ENGINE
Specification
Single cylinder, forced air cooling,
4 strokes
Rpm
3600r/min
Fuel
Gasoline
Engine Oil Capacity
0.42 Gal /1.6L
Spark Plug Type
F7TC/F7RTC (N9YC/RN9YC)
Spark Plug Clearance
0.7 mm
Valve Clearance (inlet/outlet)
0.05/0.07 mm
Igniting Mode
T.C.I.
Starting Mode
Recoild start/Electric start
Displacement
622cc
WEIGHT
(only for reference)
Net Weight
315lb/143kg
OVERALL DIMENSIONS
(excluding packing box)
L x W x H (mm)
800 x 620 x 650
Capacity of Fuel Tank
12 Gal / 48L
NOISE
(according to European Directive 2000/14/EC with
amendment 2005/88/EC)
Measured Sound Pressure Level
78 dB (A)
Measured Sound Power Level
98 dB (A)
Uncertainty
2 dB (A)
Guaranteed Sound Power Level
100 dB (A)
Shift the machine outdoors, use wire of no less than 2.5mm to make the
machine and grounding terminal connected to the ground. One end of
the wire is pressed below the butterfly nut of the unit, screwed up tightly,
and the other end is connected with the metal rod shape article (such as
the iron nail and the opener), and inserted into soil.
Remove the oil filler cap fill oil of proper model As to dosage refer to
Page 18 Use the funnel for filling in case of careless spilling clean the
ground to avoid slipping.