Version 0.2
31 July 2013
www.iHome.eu
Operating modes
The Panic Watch supports 2 different modes.
Mode 1: Alarm mode
This mode is mainly used to notify a controller of an alarm or trigger an alarm on a Z-Wave supported alarm
device.
Product can act on 2 types of handles.
When single pressed (and hold):
Press and hold the button, the duration to hold depends on the configured
values (parameter 2)
When double pressed:
quickly (within 500 msec) double press the button.
This mode can be configured with the following frame:
CONFIGURATION_SET
Parameter:
0x04
Size:
0x01 (can’t be different from 1)
Value:
0x00
Below figure shows an overview of the Z-Wave frames, values and association groups.
When single pressed (and hold)
ALARM_REPORT
Value = 0xFF
To assocation group 1
When double pressed
ALARM_REPORT
Value = 0x00
To assocation group 1