Be Next-iHome Panic Watch EU Скачать руководство пользователя страница 5

 

Version 0.2 

31 July 2013 

www.iHome.eu

 

* if a size is other then given size the frame is ignored totally so configuration values are 

not

 changed  

 

class: 0x85 COMMAND_CLASS_ASSOCIATION 

The Association Command Class is used to associate other devices with the 

Panic Watch

. The devices that are 

associated can be controlled on application level.  
 
The 

Panic Watch

 can be associated into a grouping. If so, the 

Panic Watch

 can control other Z-Wave device 

(does not have to be a controller).  
 
The Panic Watch has 2 association groups 
 
Group 1 

Maximum supported nodes: 8 
 

If configuration parameter 4 configured with value 0 then this group is used  

-

 

SOS button: send ALARM_REPORT. 

 
If configuration parameter 4 configured with value other then 0 (1-255) then this group is used  

-

 

SOS button: send BASIC_SET, 0xFF. 

Group 2 

Maximum supported nodes: 8 

 
Not used on application 
 

Class: 0x80 COMMAND_CLASS_BATTERY 

This class is used to request and report battery levels for a given device. 
When battery level is lower then 20% the Panic Watch will send a battery warning (value 255) after every wake 
up notification. A battery get will report the actual value even if below 20 %. 
 
When the batteries are placed a unsolicited battery report is sent (when included).  
 

class: 0x84 COMMAND_CLASS_WAKE_UP 

The Wake Up Command Class is used at battery-operated devices. This class allows the 

Panic Watch

 to wake 

up occasionally to notify others devices, that the 

Panic Watch

 is ready to receive commands. After receiving 

the commands the 

Panic Watch

 will go into sleep mode again. The wake up interval can be set using the 

WAKE_UP_INTERVAL_SET command.  
 
The default value is 0x15180 = 86400 sec = 24 hour 
The default node is 0xFF = 255 (broadcast) 
 
It is possible to send a 

wake up notification 

on user interaction. To do this press and hold the Panic Watch for 

11 seconds. Ignore the blinking of the led and keep the button pressed for at least 15 seconds. 
 
It is possible to send a 

wake up notification 

on user interaction. To do this press and hold the Panic Watch for4 

seconds.  

Содержание Panic Watch EU

Страница 1: ... to a Z Wave based alarm device Use 1 Before use the Panic Watch should be included into a Z Wave network and associated 2 You can Test you Panic Watch by pressing the button for 1sec untill the led is turned on press time is configurable 3 Don t forget to update and syncronize your rules in the Internet Gateway Include or Exclude in Z Wave network 1 1 Press and hold the SOS Push Button until the ...

Страница 2: ...tor light gives various statuses of the device as follows 1 Ready for learn mode indicator light blinks every second 2 Learn in progress add indicator light 2 times every second 3 Learn in progress remove indicator light 3 times every 1 5 second 4 Learn mode success indicator light is on for one second 5 RF message send success indicator light is on for one second 6 RF message send failed indicato...

Страница 3: ... initiator is used by Primary Controllers to exclude nodes from the network When the exclude initiator and a slave initiator are activated simultaneously it will result in the slave being excluded from the network and reset to Node ID zero Even if the slave was not part of the network it will still be reset by this action Z Wave compatibility Because this is a Z Wave device it means it can co oper...

Страница 4: ...tion The time that the panic pushbutton must be pressed before a panic message is sent out to the controller Default 0x64 10ms 1sec Size 1 byte Param1 if 0x00 send directly the panic message when pressed If 0x01 0xFF send a panic message after you keep holding the button pressed for this value x 10ms 3 Min led feedback time panic Description Minimum time that led feedback is shown after a panic me...

Страница 5: ...st and report battery levels for a given device When battery level is lower then 20 the Panic Watch will send a battery warning value 255 after every wake up notification A battery get will report the actual value even if below 20 When the batteries are placed a unsolicited battery report is sent when included class 0x84 COMMAND_CLASS_WAKE_UP The Wake Up Command Class is used at battery operated d...

Страница 6: ...d hold the button the duration to hold depends on the configured values parameter 2 When double pressed quickly within 500 msec double press the button This mode can be configured with the following frame CONFIGURATION_SET Parameter 0x04 Size 0x01 can t be different from 1 Value 0x00 Below figure shows an overview of the Z Wave frames values and association groups When single pressed and hold ALAR...

Страница 7: ...old depends on the configured values parameter 2 When double pressed quickly within 500 msec double press the button This mode can be configured with the following frame CONFIGURATION_SET Parameter 0x04 Size 0x01 can t be different from 1 Value 0x01 0xFF Below figure shows an overview of the Z Wave frames values and association groups When single pressed and hold BASIC_SET Value 0xFF To assocation...

Страница 8: ...guration parameter is changed back to the default value Value 0xAA Devices still has all his factory settings This are only configuration parameters wake up interval can be changed Always awake mode The always awake mode is used to request different values from the device e g version and manufacturer specific The always awake mode can be activated by CONFIGURATION_SET Parameter 0x05 Size 0x01 can ...

Страница 9: ...a value but when I request it it is not changed A It is mandatory that the correct size is used while configure a parameter go to the documentation about the configuration command class to check if the right size is used during configuration If the wrong size is used the frame is ignored totally Q I have configured a new value and when I request it the correct value is returned but the behavior is...

Отзывы: