Connecting the Appliance to the Gas Supply

 

The gas supply can be connected to the appliance by a concealed fitting from the rear. In all installation conditions the gas 
connection should be provided using 8mm (O/D) copper tubing. If the concealed installation method is chosen, there are 
three optional entry points at the rear/side of the appliance. The relevant ‘knock-out’ entry point should be removed to 
allow the gas supply to enter the appliance. 

No soldered joints 

should be used with the firebox of the appliance. The blind 

grommet which is supplied in the standard fitting pack should be used to close up the knock out hole—simply cut a small 
cross  with  a  sharp  knife  in  the  centre  of  the  grommet—this  will  then  seal  around  the  gas  pipe  to  provide  a  tight  seal. 

Under no circumstances 

should this gas entry hole be 

left open 

and 

unsealed

 as this can result in 

flame reversal 

and can 

cause 

damage

 to the appliance. 

Should this occur the warranty to this appliance will be rendered void.  

 

Before connecting the gas supply to the appliance a gas soundness test should be performed to ensure that the existing 
pipe work in the property is sound. 
 
The burner tray can now be reinstalled into the firebox.  
 
The gas connection should be made to the appliance by the 8mm restrictor isolation valve supplied with the appliance. 
 
Install the ceramics  and the glass panel to the appliance according to these instructions—see pages 8 and 15. 
 
Test  the  operating  pressure  of  the  appliance  by  attaching  a  pressure  gauge  to  the  test  point  of  the  appliance.  This 
connection should take place when the appliance is OFF. Ensure that gas is turned on at the gas meter and purge the air 
from the appliance by: 
 
MANUAL CONTROL UNITS:  Rotating the control to the      (IGN) position and push in. Every 10 seconds the knob should 

be rotated back to the     (OFF)  position and back to the IGN position to generate the spark at 
the  electrode  Check  that  the  spark  is  being  generated  correctly  at  the  pilot  assembly. 
Continue  with  this  procedure  until  the  air  is  purged  from  the  appliance  and  the  pilot  is  lit. 
Once  lit  hold  the  valve  pushed  in  for  up  to  30  seconds.  Once  the  pilot  is  established  and 
secure turn the control knob anti-clockwise to the    (HIGH) position.  Allow the appliance to 
run for a minimum period of 5 minutes. Next check that the inlet pressure to the appliance is 
at 20 mbar  ±1 mbar. 

 
SLIDE CONTROL UNITS: 

Push  down  the  control  lever  fully  to  the          (IGN)  position  and  hold.  The  spark  generator 

should  spark  continuously,  ensure  the  spark  is  being  generated  correctly  at  the  pilot 
assembly.    Continue  with  this  procedure  until  the  air  is  purged  from  the  appliance  and  the 
pilot is lit. Once lit hold the lever pushed down for up to a further 30 seconds. Once the pilot 
is established and secure allow the lever to rise to the    (LOW) position then lift the lever to 
the     (HIGH) position.  Allow the appliance to run for a minimum period of 5 minutes. Next 
check that the inlet pressure to the appliance is 20 mbar  ±1 mbar. 

 
Check the operation of the appliance according to these instructions—see page 14. 

 

Check the clearance of combustion products 

 

SPILLAGE  TEST: 

To check for satisfactory clearance of 

products  of  combustion,  close  all doors and  windows 
and  leave  the  appliance  burning  on  HIGH  for  five 
minutes.  Insert  a  lit  smoke  match  just  into  the  gap  a 
the  top  centre  of  the  fire.  It  is  recommended  that a 
smoke  match  holder  be  used.  All  the  smoke  must  be 
drawn into the flue. If spillage occurs allow a further 5 
minutes and repeat the test. If spillage still occurs turn 
off  the  appliance  and  seek  expert  advise  to  expert 
advice.  If  an  extractor fan  is  situated  in  the  room  the 
spillage test should be repeated with the fan running. 
If there is a connecting room with an extractor fan the 
test  should  be  repeated  with  all  the  doors  to  that 
room open and the extractor fan running. 

Содержание BM-05XXX1

Страница 1: ...ngineer to ensure that the customer is able to fully operate the appliance and is aware of any cleaning or maintenance requirements FULL DEPTH HE GAS FIRE Model numbers BM 05XXX1 MANUAL for use on Nat...

Страница 2: ...ement 8 Fixing the Appliance 7 Connecting the Appliance to the Gas Supply 9 Checking Operation of Appliance 9 Completing the Installation 10 Appliance Technical Information 11 Cleaning Instructions 11...

Страница 3: ...1996 Domestic Gas Installation Republic of Ireland Prior to installation ensure that the gas supply is compatible with the appliance this appliance must only be used on natural gas at a supply pressur...

Страница 4: ...to a suitable hearth with a minimum thickness of 12mm The appliance must not be installed directly onto carpet of other combustible floor materials The fireplace surround back panel must have a tempe...

Страница 5: ...se of the fireplace opening is flat and level with the hearth surface to ensure a secure and aligned installation of the appliance The minimum hearth dimensions are shown in the diagram above The uppe...

Страница 6: ...his advice not be followed the customer should be advised to give due to consideration to the safety of the occupants in the room where the appliance is to be installed 3 The user must be made aware t...

Страница 7: ...and the foam seal which is supplied with the appliance should be affixed to the rear face of the spacer Do not use any permanent sealing substance as this will invalidate warranty as the appliance can...

Страница 8: ...the seal around the top and two sides of the firebox is in good condition and is securely affixed to the appliance If the seal is damaged of loose then it should be replaced reaffixed before the glas...

Страница 9: ...he OFF position and back to the IGN position to generate the spark at the electrode Check that the spark is being generated correctly at the pilot assembly Continue with this procedure until the air i...

Страница 10: ...in to the customer that the ceramics are fragile and must be treated with great care explain that the ceramics are not covered by the warranty because of their fragility Also explain that small hairli...

Страница 11: ...with the greatest of care Cleaning of these components should only be undertaken once the appliance is switched off and has been allowed to cool for a minimum period of one hour The components should...

Страница 12: ...mponents will require the removal of the burner tray The following information details the removal of this tray Once removed refer to the relevant section that follows detailing the removal of the spe...

Страница 13: ...page Replacement of the Pilot 1 Remove the four 2 screws to remove the cover panel 2 Undo the pilot gas supply from the base of the pilot 3 Remove the thermocouple nut from the back of thevalve 4 Remo...

Страница 14: ...the spark generator fail to provide a spark at the electrode it may be that a small amount of soot has fallen from the fuel bed onto the pilot assembly causing a short circuit If this is the case ensu...

Страница 15: ...f it does not fit easily then you are not fitting the part correctly These instructions can also be followed to remove or reinstall the fuel bed after cleaning This is a procedure that can be undertak...

Страница 16: ...onto the front rail and lean against the fuel bed as shown in the picture below Step 4 Carefully place five coals onto the fuel bed as shown in the picture below Step 5 Fit three coals into position a...

Страница 17: ...17 Fit Trim to Appliance Position the four magnets supplied in the fitting pack to the rear face of the trim as shown below STANDARD TRIM TWO TONE TRIM Now fit the trim to the appliance...

Страница 18: ...our policy of continual product improvement some diagrams and small details may not be accurate however if there is any concern or matter of understanding that you feel needs to be clarified please co...

Отзывы: