Be Modern BM-05XXX1 Скачать руководство пользователя страница 3

 

REGULATORY INFORMATION AND INSTALLATION REQUIREMENTS

 

 

THE FOLLOWING MUST BE NOTED PRIOR TO THE INSTALLATION OF THIS APPLIANCE. 

 

This  gas  appliance  MUST  be  installed  by  a  GAS  SAFE  registered  installer  by  law.  It  must  be  installed  in 
accordance to these installation instructions and the GAS SAFETY (Installation & Use) REGULATIONS 1998 as 
amended.  Non  compliance  of  this  law  may  lead  to  prosecution  and  it  is  in  the  interest  of  you  and  your 
family that this condition is observed. 
 
The  installation  of  this  appliance  must  be  in  accordance  with  the  relevant  parts  of  the  LOCAL  AND 
NATIONAL  BUILDING  REGULATIONS  as  issued  by  the  Department  of  the  Environment  or  BUILDING 
STANDARD  (Scotland  Consolidation)  REGULATIONS  issued  by  the  Scottish  Development  Department  and 
the following relevant British Standards: 
 

BS5871   

 

 

Part 2 Installation of Inset Live Fuel Effect Gas Fires 

BS5440    

 

 

Parts 1 & 2 Installation of Flues and Ventilation 

BS6891   

 

 

Installation of Gas Pipe-work 

BS6461   

 

 

Part 1 Installation of Chimneys and Flues 

BS1251   

 

 

Open Fireplace Components 

BS715/BS EN 1856-2   

Metal Flue Boxes  / Metal Flue Pipes for Gas Appliances 

BS EN 1858 

 

 

Chimneys Components & Concrete Flue Blocks 

IS813:1996 

 

 

Domestic Gas Installation (Republic of Ireland) 

 

Prior to installation ensure that the gas supply is compatible with the appliance, this appliance must only be 
used on 

natural gas 

at a supply pressure of 20 mbar as marked on the data plate on the appliance and the 

carton. 
 
This appliance is only to be installed into a builder opening which must be constructed of non-combustible 
materials  confirming  to  BS1251  or  a  suitable  flue-box  complying  with  the  requirements  of  BS715/BS  EN 
1856-2. 
 
If the product is being installed into a builders opening the chimney must be at least 3 metres in height and 
should be swept before installation if it has been used for the burning of solid fuel (e.g. coal or wood). The 
chimney must only serve as a flue-way  to this appliance and must have no openings to any other room. The 
opening  should  be  inspected  and  any  exposed  brickwork  should  be  repaired  where  necessary.  The  chair- 
brick (if applicable) should be removed. Ensure that the chimney/flue only serves one fireplace. Remove or 
securely fix open and dampers or register plates. 
 
If  the  product  is  being  installed  into  a  fabricated  Flue-box  (to  BS715)  it  must  be  installed  onto  a  non-
combustible surface with a thickness of at least  12mm.  
 
 
The  flue  should  be  checked  for  draw  using  a  smoke  bomb  or  similar,  if  there  is  a  definite  draw  then  the 
installation of the appliance can proceed. 

 

Содержание BM-05XXX1

Страница 1: ...ngineer to ensure that the customer is able to fully operate the appliance and is aware of any cleaning or maintenance requirements FULL DEPTH HE GAS FIRE Model numbers BM 05XXX1 MANUAL for use on Nat...

Страница 2: ...ement 8 Fixing the Appliance 7 Connecting the Appliance to the Gas Supply 9 Checking Operation of Appliance 9 Completing the Installation 10 Appliance Technical Information 11 Cleaning Instructions 11...

Страница 3: ...1996 Domestic Gas Installation Republic of Ireland Prior to installation ensure that the gas supply is compatible with the appliance this appliance must only be used on natural gas at a supply pressur...

Страница 4: ...to a suitable hearth with a minimum thickness of 12mm The appliance must not be installed directly onto carpet of other combustible floor materials The fireplace surround back panel must have a tempe...

Страница 5: ...se of the fireplace opening is flat and level with the hearth surface to ensure a secure and aligned installation of the appliance The minimum hearth dimensions are shown in the diagram above The uppe...

Страница 6: ...his advice not be followed the customer should be advised to give due to consideration to the safety of the occupants in the room where the appliance is to be installed 3 The user must be made aware t...

Страница 7: ...and the foam seal which is supplied with the appliance should be affixed to the rear face of the spacer Do not use any permanent sealing substance as this will invalidate warranty as the appliance can...

Страница 8: ...the seal around the top and two sides of the firebox is in good condition and is securely affixed to the appliance If the seal is damaged of loose then it should be replaced reaffixed before the glas...

Страница 9: ...he OFF position and back to the IGN position to generate the spark at the electrode Check that the spark is being generated correctly at the pilot assembly Continue with this procedure until the air i...

Страница 10: ...in to the customer that the ceramics are fragile and must be treated with great care explain that the ceramics are not covered by the warranty because of their fragility Also explain that small hairli...

Страница 11: ...with the greatest of care Cleaning of these components should only be undertaken once the appliance is switched off and has been allowed to cool for a minimum period of one hour The components should...

Страница 12: ...mponents will require the removal of the burner tray The following information details the removal of this tray Once removed refer to the relevant section that follows detailing the removal of the spe...

Страница 13: ...page Replacement of the Pilot 1 Remove the four 2 screws to remove the cover panel 2 Undo the pilot gas supply from the base of the pilot 3 Remove the thermocouple nut from the back of thevalve 4 Remo...

Страница 14: ...the spark generator fail to provide a spark at the electrode it may be that a small amount of soot has fallen from the fuel bed onto the pilot assembly causing a short circuit If this is the case ensu...

Страница 15: ...f it does not fit easily then you are not fitting the part correctly These instructions can also be followed to remove or reinstall the fuel bed after cleaning This is a procedure that can be undertak...

Страница 16: ...onto the front rail and lean against the fuel bed as shown in the picture below Step 4 Carefully place five coals onto the fuel bed as shown in the picture below Step 5 Fit three coals into position a...

Страница 17: ...17 Fit Trim to Appliance Position the four magnets supplied in the fitting pack to the rear face of the trim as shown below STANDARD TRIM TWO TONE TRIM Now fit the trim to the appliance...

Страница 18: ...our policy of continual product improvement some diagrams and small details may not be accurate however if there is any concern or matter of understanding that you feel needs to be clarified please co...

Отзывы: