Be Modern BM-05XXX1 Скачать руководство пользователя страница 11

 

11 

Maintenance of the Appliance

 

The following procedures can and should be performed by the 

customer 

at regular intervals depending upon use of the 

appliance. 
 

Appliance Technical Information 

Gas Type :  Natural 

 

 

Gas Category : I2H  

 

Inlet Pressure: (Cold) 20mbar    

Heat Input Gross : 5.5kW  

 

Injector   :  69 

 

 

Destination Countries : GB/ IE 

 

HEALTH AND SAFETY NOTICE

 

This  appliance  uses  fuel  effect  pieces  manufactured  from  Refractory  Ceramic  Fibres  (RCF).  Care  must  be  taken  to  avoid 
excessive exposure to these materials as they may cause irritation to the eyes, skin, nose and throat. When Handling avoid 
inhaling and contact with skin and eyes. It is recommended that disposable gloves are worn in addition to a facemask and 
eye protection. After handling wash hands thoroughly and any other exposed parts which may have come in to contact with 
the material. 
 
If a vacuum cleaner is used to clean the fuel bed or areas around the appliance there fragments of the material may have 
fallen it is recommended that it be of the type fitted with a HEPA filter. 
 
Care should be taken when disposing of RCF materials. It is important to keep any dust to a minimum so it is recommended 
that  the  fuel  effect  components  are  placed  into  a  heavy  duty  plastic  bag.  The bag  should  be  clearly  labelled 

RCF  WASTE

These  materials  are  not  classified  as  hazardous  waste  and  should  be  disposed  of  at  a  site  approved  for  the  disposal  of 
industrial waste.  

 
Cleaning the Appliance 
Fuel Bed 

The fuel effect components supplied with this product are extremely fragile and must be handled with great care. The 
ceramics in this appliance are not covered by the warranty due to their fragility. This includes the RCF fibre boards in the 
fire box. These components will break or chip if not handled with the greatest of care. 
 
Cleaning of these components should only be undertaken once the appliance is switched off and has been allowed to 
cool  for  a minimum  period  of one  hour.  The  components  should  be  lifted  carefully  piece  by  piece  from the  appliance 
and placed onto a dust sheet or similar. They can be brushed gently with a soft brush to remove any dust or deposits. If 
you  intend  to  use  a  vacuum  cleaner  then  this  should  only  be  done  once  the  loose  deposits  of  soot  etc  have  been 
removed.  Ensure  that  the  moulded  components  are  structurally  sound  and  no  significant  part  of  the  moulding  has 
broken  away.  If  any  component  has  broken  then  it  should  be  replaced  before  using  the  appliance.  Only  the  correct 
replacement  part  as  supplied  by  the  manufacturer  shall  be  used  in  this  appliance.  Do  not  add  any  additional 
components  to  the  fuel  bed  layout.  It  is  important to  note  that  small  hairline  cracks  will  appear  in  the  surface  of  the 
ceramics due to heat expansion and contraction—this is perfectly normal. 
 

Pilot 

The  pilot  to  this  appliance  has  a  small  aeration  hole at  its 
base. Using a thin nozzle on a vacuum cleaner this area can 
be  cleaned  to  prevent  a  lint  build  up.  This  procedure 
should  only  be  undertaken  when  the  appliance  is  off  and 
cold.  If  excessive  lint  is  drawn  in  through  this  hole  due  to 
infrequent cleaning then it may result in the appliance not 
lighting  or  turning  itself  off  automatically  due  to  a 
starvation  of  air  at  the  pilot  burner.  This  can  often  be 
remedied  by  performing  the  cleaning  operation  detailed 
here.  If  this  procedure  does  not  resolve  such  a  problem 
then the pilot assembly will need to be replaced. This must 
involve  the  installation  of  the  same  part  as  supplied  by  the  manufacturer.  Excessive  lint  build  up  which  results  in 
appliance operational problems is not covered by warranty. It is important to ensure this preventative maintenance is 
performed regularly (once a month during the winter period).

 

Содержание BM-05XXX1

Страница 1: ...ngineer to ensure that the customer is able to fully operate the appliance and is aware of any cleaning or maintenance requirements FULL DEPTH HE GAS FIRE Model numbers BM 05XXX1 MANUAL for use on Nat...

Страница 2: ...ement 8 Fixing the Appliance 7 Connecting the Appliance to the Gas Supply 9 Checking Operation of Appliance 9 Completing the Installation 10 Appliance Technical Information 11 Cleaning Instructions 11...

Страница 3: ...1996 Domestic Gas Installation Republic of Ireland Prior to installation ensure that the gas supply is compatible with the appliance this appliance must only be used on natural gas at a supply pressur...

Страница 4: ...to a suitable hearth with a minimum thickness of 12mm The appliance must not be installed directly onto carpet of other combustible floor materials The fireplace surround back panel must have a tempe...

Страница 5: ...se of the fireplace opening is flat and level with the hearth surface to ensure a secure and aligned installation of the appliance The minimum hearth dimensions are shown in the diagram above The uppe...

Страница 6: ...his advice not be followed the customer should be advised to give due to consideration to the safety of the occupants in the room where the appliance is to be installed 3 The user must be made aware t...

Страница 7: ...and the foam seal which is supplied with the appliance should be affixed to the rear face of the spacer Do not use any permanent sealing substance as this will invalidate warranty as the appliance can...

Страница 8: ...the seal around the top and two sides of the firebox is in good condition and is securely affixed to the appliance If the seal is damaged of loose then it should be replaced reaffixed before the glas...

Страница 9: ...he OFF position and back to the IGN position to generate the spark at the electrode Check that the spark is being generated correctly at the pilot assembly Continue with this procedure until the air i...

Страница 10: ...in to the customer that the ceramics are fragile and must be treated with great care explain that the ceramics are not covered by the warranty because of their fragility Also explain that small hairli...

Страница 11: ...with the greatest of care Cleaning of these components should only be undertaken once the appliance is switched off and has been allowed to cool for a minimum period of one hour The components should...

Страница 12: ...mponents will require the removal of the burner tray The following information details the removal of this tray Once removed refer to the relevant section that follows detailing the removal of the spe...

Страница 13: ...page Replacement of the Pilot 1 Remove the four 2 screws to remove the cover panel 2 Undo the pilot gas supply from the base of the pilot 3 Remove the thermocouple nut from the back of thevalve 4 Remo...

Страница 14: ...the spark generator fail to provide a spark at the electrode it may be that a small amount of soot has fallen from the fuel bed onto the pilot assembly causing a short circuit If this is the case ensu...

Страница 15: ...f it does not fit easily then you are not fitting the part correctly These instructions can also be followed to remove or reinstall the fuel bed after cleaning This is a procedure that can be undertak...

Страница 16: ...onto the front rail and lean against the fuel bed as shown in the picture below Step 4 Carefully place five coals onto the fuel bed as shown in the picture below Step 5 Fit three coals into position a...

Страница 17: ...17 Fit Trim to Appliance Position the four magnets supplied in the fitting pack to the rear face of the trim as shown below STANDARD TRIM TWO TONE TRIM Now fit the trim to the appliance...

Страница 18: ...our policy of continual product improvement some diagrams and small details may not be accurate however if there is any concern or matter of understanding that you feel needs to be clarified please co...

Отзывы: