ADDITIONAL INSTRUCTIONS
57GUNMOD
a) The flow-meter, according to the appropriate oil adjustment within the system itself, there is a traffic
parameter value (gear rotates a cycle pulse oil value) set values, such as 000236, as shown in Picture 10,
customers can change according to their own requirements.
For example, the need to display a large number of changes, such as 000242, in accordance with the above
point 4, hold down the Reset button 2 seconds, the instruments automatically enters the set state to change.
As shown in Picture 11.
Note
: After, hold the Reset for 2 seconds, the instrument will re save the new parameters, into the normal state,
as shown in Picture 12.
b) If there is errors on filling rate parameters (the factory has set a numerical table) into other codes, 005374,
at the same time, can also be adjusted according to the same method, until the actual injection quantity and
injection quantity display, basically the same, to determine the parameters saved successfully qualified.
Note
: Before you start filling oil, please rectify it for several times until it is completed to number you would
like to fill.
SENSOR DEBUGGING
Press right key to clear actual oil amount, get some oil (note: oral gear should rotate one cycle at least),
press left key for 3 seconds (do not loosen) all the time and see, If 10000 or 9999 or 10001 is shown on display,
the sensor is normal, but if the value is less 2 or more than actual value, so one sensor is not normal. Oral gear
turning one cycle can produce 8 signals. You can debug by hand. After you see the sensor record, press left key
for 3 seconds, and do not loosen, the instrument will be back to running state. (Note: instrument at work, must
be in the running state).