BDS AirMAB 5000 Скачать руководство пользователя страница 14

13

Use

AirMAB 5000

GB

Use

Activating/deactivating the mag-

netic clamp

Activating the magnetic clamp

Turn the lever for the permanent 

 

‹

magnet (11) to the right (ON position) 
to activate the magnets.

Deactivating the magnetic clamp

Hold the handle tightly (5) to stop the 

 

‹

machine from slipping.

Push the locking button (12) and turn 

 

‹

the lever (11) for the magnetic clamps 
to the left (OFF position) to release the 
magnets.

Switching the machine ON/OFF

Switching on the machine

Turn the motor switch (10) to the ON 

 

‹

position to activate the motor.

Switching off the machine

Turn the motor switch (10) to the OFF 

 

‹

position to deactivate the motor.

 WARNING

Risk of injury from motor starting 
unintentionally!

Pay attention to the following safety 
notes to avoid danger from motor starting 
unintentionally:

To completely stop the motor:  

 

Move the motor switch to the OFF 
position. 
Disconnect the compressed air sup-
ply.

Drilling with the machine

Drilling with core drills

When drilling with core drills, proceed as 
follows:

Mount the KEYLESS quick-change 

 

‹

drill chuck system (A).

Install the appropriate ejector pin 

 

‹

in the core drill and insert the core 
drill into the quick-change drill chuck 
system.

Place the machine at the working loca-

 

‹

tion, align it and switch on the mag-
netic clamps.

 NOTE

Observe the following instructions when 
drilling with core drills:

Drilling with core drills does not re-

 

quire great force. The drilling process 
is not accelerated by higher pres-
sure. The drill wears faster and the 
machine can be overloaded. 

Use the pump bottle for cutting oil/

 

drilling emulsion (21) with BDS 5000 
high-performance cutting oil supplied 
for the machine.

When working overhead, use 

 

ZHS 400 high-performance grease 
spray. Spray the drill with grease 
spray on the inside and outside 
before drilling. Repeat this procedure 
when drilling deeper holes.

Make sure that swarf is removed 

 

regularly. With larger drilling depths, 
break the chip.

Содержание AirMAB 5000

Страница 1: ...AirMAB 5000 Original Operating Instructions GB...

Страница 2: ...8 5 4 2 1 6 3 7 9 10 11 12...

Страница 3: ...21 A B C 20 22 23...

Страница 4: ...nting in whole or in part and the reproduction of the illustrations even in modified form is only permitted with the written approval of the manufacturer Liability disclaimer All technical information...

Страница 5: ...on that simplifies the use of the machine Intended use The machine is intended solely for drilling operations in magnetic and non magnetic metals within the limits specified in the technical data Any...

Страница 6: ...in and the function of the operating elements of the machine Only allow repairs to the machine to be carried out by an authorised workshop or customer service Unqualified repairs can lead to considera...

Страница 7: ...NG Risk of injury from motor starting unintentionally Pay attention to the following safety notes to avoid danger from motor starting unintentionally To completely stop the motor Move the motor switch...

Страница 8: ...ng the tool section Do not allow the compressed air line to hang over edges trip wire effect Preventing damage CAUTION Potential damage to property if the machine is improperly used Observe the follow...

Страница 9: ...r head against falling objects Wear a harness where there is a danger of falling Gloves for protection against injuries Components delivery contents Machine overview 1 Core drill not supplied as stand...

Страница 10: ...e machine must be secured to prevent it from falling using the safety chain B supplied Check the safety chain for proper function before every use A dam aged safety chain must not be used Replace a da...

Страница 11: ...kness steel an additional steel plate minimum dimensions 100 x 200 x 20 mm must be placed under the workpiece Secure the steel plate to prevent it from falling NF metals or workpieces with an uneven s...

Страница 12: ...g the tool Insert the ejector pin C into the ejector pin holder of the spindle taper MK2 3 Lever out the tool with the ejector pin C or loosen the tool by tapping against the ejector pin Using the dri...

Страница 13: ...outside sleeve and pull the tool down out of the chuck Compressed air supply Perfect function and performance of the drive unit depends on the air quality and the quantity of air supplied The followin...

Страница 14: ...n Disconnect the compressed air sup ply Drilling with the machine Drilling with core drills When drilling with core drills proceed as follows Mount the KEYLESS quick change drill chuck system A Instal...

Страница 15: ...tool parts or swarf Put protective gloves on before start ing work Blockages caused by a broken tool Switch the machine off using the mo tor switch Leave the magnetic clamp switched on Disconnect the...

Страница 16: ...chine Clean the guide of the machine slide Put the machine and accessories into the transport case Maintenance WARNING Danger caused by unqualified repairs Unqualified repairs can lead to consider abl...

Страница 17: ...t connected Connect the compressed air supply Compressed air supply not switched on Switch on the compressed air supply Compressed air supply not sufficient Check the compressed air supply and set up...

Страница 18: ...foot L x W x H 90 x 190 x 60 mm Approx net weight 17 5 kg Motor power 830 W Nominal torque 27 Nm Air consumption 1000 l min Noise emission 96 db A Vibration 1 55 m s Stroke 160 mm Core drill short max...

Страница 19: ...ve 2006 42 EC on machinery The following harmonised standards were applied in whole or in part DIN EN ISO 12100 2010 DIN EN ISO 11148 3 2013 Responsible person for documentation according to EC Direct...