BDS AirMAB 5000 Скачать руководство пользователя страница 13

12

Preparation

AirMAB 5000

GB

Keyless quick-change drill chuck 

system 

Inserting the tool

Before mounting, clean the shank of 

 

‹

the tool, adapter or drill chuck and the 
spindle taper (3) of the machine.

Push the KEYLESS quick-change drill 

 

‹

chuck system (A)  from below into the 
spindle taper of the machine.

Connect the line of the pump bottle for 

 

‹

cutting oil/drilling emulsion (21) to the 

connection for the KEYLESS quick-

change drill chuck system.

Open the KEYLESS quick-change 

 

‹

drill chuck system by pushing up the 
outside sleeve and insert the tool into 
the chuck.

 NOTE

Insert the appropriate ejector pin 

 

before inserting the core drill.

 WARNING

Risk of injury from incorrectly inserted 
tool or tool mounting!

Check by briefly turning the tool 

 

whether the collet is engaged.

Removing the tool

Open the KEYLESS quick-change drill 

 

‹

chuck system (A) by pushing up the 
outside sleeve and pull the tool down 
out of the chuck.

Compressed air supply 

Perfect function and performance of the 
drive unit depends on the air quality and 
the quantity of air supplied.

The following requirements must be met 
by the compressed air in order to achieve 
perfect function and performance of the 
drive unit:

The air quality is optimum at a dew 

 

point of 10 °C and precipitation of solid 
particles larger than 15 micrometres as 
well as 90 % of liquid water.

The compressed air must contain oil 

 

in order to guarantee the required air 
lubrication.

Set the oil quantity according to the air 

 

requirement. 

L

 = air consumption (1/sec) 

D

 = number of drops per minute 

(1 drops = 15 mm²); 

L * 0 .2 = D

.

The compressed air connection must 

 

have an operating pressure of 6 - 7 bar 
= 600 - 700 kPa = 6 - 7 kp/cm².

Before connecting, blow through the 

 

compressed air hose carefully to clean 
it. 
Hose diameter: min.10 mm (3/8").

 NOTE

Only connect to the machine when it 

 

is switched off.

Air consumption of the motor is 

 

1000 l/min. 
The motor performance is reduced 
when the air supply is decreased!

Содержание AirMAB 5000

Страница 1: ...AirMAB 5000 Original Operating Instructions GB...

Страница 2: ...8 5 4 2 1 6 3 7 9 10 11 12...

Страница 3: ...21 A B C 20 22 23...

Страница 4: ...nting in whole or in part and the reproduction of the illustrations even in modified form is only permitted with the written approval of the manufacturer Liability disclaimer All technical information...

Страница 5: ...on that simplifies the use of the machine Intended use The machine is intended solely for drilling operations in magnetic and non magnetic metals within the limits specified in the technical data Any...

Страница 6: ...in and the function of the operating elements of the machine Only allow repairs to the machine to be carried out by an authorised workshop or customer service Unqualified repairs can lead to considera...

Страница 7: ...NG Risk of injury from motor starting unintentionally Pay attention to the following safety notes to avoid danger from motor starting unintentionally To completely stop the motor Move the motor switch...

Страница 8: ...ng the tool section Do not allow the compressed air line to hang over edges trip wire effect Preventing damage CAUTION Potential damage to property if the machine is improperly used Observe the follow...

Страница 9: ...r head against falling objects Wear a harness where there is a danger of falling Gloves for protection against injuries Components delivery contents Machine overview 1 Core drill not supplied as stand...

Страница 10: ...e machine must be secured to prevent it from falling using the safety chain B supplied Check the safety chain for proper function before every use A dam aged safety chain must not be used Replace a da...

Страница 11: ...kness steel an additional steel plate minimum dimensions 100 x 200 x 20 mm must be placed under the workpiece Secure the steel plate to prevent it from falling NF metals or workpieces with an uneven s...

Страница 12: ...g the tool Insert the ejector pin C into the ejector pin holder of the spindle taper MK2 3 Lever out the tool with the ejector pin C or loosen the tool by tapping against the ejector pin Using the dri...

Страница 13: ...outside sleeve and pull the tool down out of the chuck Compressed air supply Perfect function and performance of the drive unit depends on the air quality and the quantity of air supplied The followin...

Страница 14: ...n Disconnect the compressed air sup ply Drilling with the machine Drilling with core drills When drilling with core drills proceed as follows Mount the KEYLESS quick change drill chuck system A Instal...

Страница 15: ...tool parts or swarf Put protective gloves on before start ing work Blockages caused by a broken tool Switch the machine off using the mo tor switch Leave the magnetic clamp switched on Disconnect the...

Страница 16: ...chine Clean the guide of the machine slide Put the machine and accessories into the transport case Maintenance WARNING Danger caused by unqualified repairs Unqualified repairs can lead to consider abl...

Страница 17: ...t connected Connect the compressed air supply Compressed air supply not switched on Switch on the compressed air supply Compressed air supply not sufficient Check the compressed air supply and set up...

Страница 18: ...foot L x W x H 90 x 190 x 60 mm Approx net weight 17 5 kg Motor power 830 W Nominal torque 27 Nm Air consumption 1000 l min Noise emission 96 db A Vibration 1 55 m s Stroke 160 mm Core drill short max...

Страница 19: ...ve 2006 42 EC on machinery The following harmonised standards were applied in whole or in part DIN EN ISO 12100 2010 DIN EN ISO 11148 3 2013 Responsible person for documentation according to EC Direct...

Отзывы: