Remote Control – Parallel/GPIO DB9F Connection Table 2. 
 

Pin 1 +5 VDC @100mA. 
Pin 2  Auto Mode Select 
Pin 3 Select B Input 
Pin 4 Select A Input 
Pin 5 Error Reset 
Pin 6 Status Common  
Pin 7 Status – “B” Selected 
Pin 8 Status - “A” Selected 
Pin 9 Auto Mode Status 
 
Command input pins 2, 3, 4, 5 require a momentary closure to ground. Status connections open 
collector outputs which require a 5 VDC pull up.   
 

 

 
 
 
 

Remote Control RS-232 Connection Diagram

 

 

 

 

 

Содержание AES-402

Страница 1: ...ces Inc AES 402 Automatic Digital Audio Switcher DA Digital to Analog Converter Technical Reference Manual Broadcast Devices Inc Tel 914 737 5032 Fax 914 736 6916 World Wide Web www Broadcast Devices com Rev B 03 14 ...

Страница 2: ...duction 3 I Unpacking 3 II Installation and Connections 3 III Features and Operation 4 IV Initial Operating Setup 4 5 AES 402 Optional Programming Functions 5 6 Remote Control Connections 7 V Specifications 8 VI Warranty 9 2 ...

Страница 3: ...ck to locate the unit Determine the local electrical power supply voltage As supplied from the factory your AES 402 is setup for 100 240 V A C 50 60 Hz No external adjustment for local power standards is necessary if power available conforms to the above rating The AES 402 utilizes a switch mode power supply and automatically adjusts for local power entry Make connections to the unit following goo...

Страница 4: ...ation the relays energize and AES 4 output receives its signal from the last selected input before power was removed An optional delay is provided to prevent the unit from switching on momentary interruptions that can occur in external equipment Through application of a DIP switch the unit can either switch immediately upon detection of digital errors or wait 5 seconds and then switch This delay p...

Страница 5: ... switch to the alternate path and remain there until the error reset is performed from the front panel or remotely When in AUTO mode and an error occurs the unit will go to manual mode and the MAN button and error indication will flash to indicate that an error has occurred To clear the error depress the ERROR button If the error clears the ERROR button LED will extinguish error indicators will ex...

Страница 6: ... S1 5 to off position This will allow the AES 402 unit to act as a manual digital audio switcher for non PCM audio streams and defeats the silence sensor which cannot be used in the is mode of operation AES 402 DIP Switch Programming Guide of Operation Table 1 S1 1 OFF Front Panel Button Disables A B and AUTO MAN Buttons Factory Default ON Silence Sensor Time out Parameters S1 3 S1 2 Silence Timeo...

Страница 7: ...put Pin 4 Select A Input Pin 5 Error Reset Pin 6 Status Common Pin 7 Status B Selected Pin 8 Status A Selected Pin 9 Auto Mode Status Command input pins 2 3 4 5 require a momentary closure to ground Status connections open collector outputs which require a 5 VDC pull up Remote Control RS 232 Connection Diagram 7 ...

Страница 8: ...ush buttons Switcher Selection Error Reset Auto Manual Mode Operation Select Volume Up Down Front Panel Indicators Sample Rate Lock Loss Error Flags Channel Status Auto Manual Mode Power Requirements 100 240 V A C 0 25A 50 60 Hz Operating Environment 0 60 Degrees Celsius Non Condensing Atmosphere Physical 19 W X 8 D X 1 75 H Mounted via Standard E I A 19 rack one rack unit occupied Weight 8 LBS FC...

Страница 9: ...de of the carton Any packages received without such R A number will be refused Note freight collect shipments will also be refused When the unit has been received inspected and tested the customer will receive a report of the findings along with a quotation for recommended repairs which are found falling outside of the standard warranty Units returned for in warranty repairs which are found not to...

Отзывы: