Initial Power Application

 

 
Once power is applied and a valid AES bit stream is applied to the selected input, the unit will 
default to “MAN” mode of operation. The LED indicator over the “MAN” button should be 
illuminated. In addition, the channel selected LED indicator will be lit or flashing which indicates 
audio level under threshold for at least 5 seconds. This feature allows the user to determine if 
audio level is sufficient to drive the unit or for troubleshooting purposes. This feature can be 
defeated if desired by setting DIP SW1-6 to the OFF position. In the OFF position the unit will 
always indicate channel selection with a steady lighted indication. There should also be an 
indication of sample frequency. The AES-402 supports any sample rate between 32 and 192 
KHz. Standard sample rates are indicated on the front panel under “Sample Rate” and non 
standard sample rates are indicated with the “OTHER” LED indication being illuminated.  Press 
the error-reset button to clear any errors that might be indicated. If the digital audio stream 
feeding the active channel of the unit is valid and no errors occur the unit is ready for to be placed 
in the automatic mode if desired. If any of these errors occur after depressing the error-reset 
button, then the feed to the unit is defective and should be investigated. If all is in order, the unit is 
now ready for operation. All that is left to do is to select the desired feed and then if desired, place 
the unit in automatic switch mode by depressing the “AUTO” mode button. The LED indicator will 
light indicating automatic control of the switcher. The unit will remain in this mode until an error is 
detected, loss of lock occurs, silence or is detected. If any of these events occur, the unit will 
switch to the alternate path and remain there until the error reset is performed from the front 
panel or remotely. When in AUTO mode and an error occurs the unit will go to manual mode and 
the “MAN”  button and error indication will flash to indicate that an error has occurred. To clear 
the error, depress the “ERROR” button. If the error clears the “ERROR” button LED will 
extinguish, error indicators will extinguish and the “MAN” button will remain illuminated until the 
“AUTO” button is depressed.  
 

Description of AES-402 Optional Programming Functions 
 

S1-1 Front Panel Button Defeat

 – When set to on will cause the A/B, MAN and AUTO buttons to 

be non operational. Rear panel GPIO and serial remote control are still available when this switch 
is turned on.  
 

S1 -2, 3 Time Delay

 – Sets the time delay that the silence sensor will wait before switching. Time 

delay can be set to 30, 60, 90 or 120 seconds. 
 

S1-4, 5 Silence Detector Channel

 – Can be set to monitor both (L+R) or left only/right only. 

When set to both, the silence detector will switch to the alternate path if one or both channels 
signal level fall below threshold for the time delay set. For Left or Right only the silence sensor 
will only switch after the channel being monitored times out. The unselected channel is ignored.  
 

S1-6 Silence Indication on A/B Buttons

 – Will cause the selected channel button to flash if 

audio level falls below threshold for more than 15 seconds. Set to off for steady on condition of 
A/B buttons.  
 

S1-8 Serial Remote Control

 – Turns on serial remote control functionality. 

 

S2-1 AES ERROR Switching delay

 – when enabled ignores all momentary digital errors under 5 

seconds in duration – eliminates inadvertent switching on transient events. When switched to off 
position switcher switches channels immediately upon detection of any digital error flags enabled 
by S2-2, 3, 5 
 

S2-2 Unlock Error

 - When set to on will cause the switcher to switch as per S2-1 setting for an 

unlock condition. 
 

 

Содержание AES-402

Страница 1: ...ces Inc AES 402 Automatic Digital Audio Switcher DA Digital to Analog Converter Technical Reference Manual Broadcast Devices Inc Tel 914 737 5032 Fax 914 736 6916 World Wide Web www Broadcast Devices com Rev B 03 14 ...

Страница 2: ...duction 3 I Unpacking 3 II Installation and Connections 3 III Features and Operation 4 IV Initial Operating Setup 4 5 AES 402 Optional Programming Functions 5 6 Remote Control Connections 7 V Specifications 8 VI Warranty 9 2 ...

Страница 3: ...ck to locate the unit Determine the local electrical power supply voltage As supplied from the factory your AES 402 is setup for 100 240 V A C 50 60 Hz No external adjustment for local power standards is necessary if power available conforms to the above rating The AES 402 utilizes a switch mode power supply and automatically adjusts for local power entry Make connections to the unit following goo...

Страница 4: ...ation the relays energize and AES 4 output receives its signal from the last selected input before power was removed An optional delay is provided to prevent the unit from switching on momentary interruptions that can occur in external equipment Through application of a DIP switch the unit can either switch immediately upon detection of digital errors or wait 5 seconds and then switch This delay p...

Страница 5: ... switch to the alternate path and remain there until the error reset is performed from the front panel or remotely When in AUTO mode and an error occurs the unit will go to manual mode and the MAN button and error indication will flash to indicate that an error has occurred To clear the error depress the ERROR button If the error clears the ERROR button LED will extinguish error indicators will ex...

Страница 6: ... S1 5 to off position This will allow the AES 402 unit to act as a manual digital audio switcher for non PCM audio streams and defeats the silence sensor which cannot be used in the is mode of operation AES 402 DIP Switch Programming Guide of Operation Table 1 S1 1 OFF Front Panel Button Disables A B and AUTO MAN Buttons Factory Default ON Silence Sensor Time out Parameters S1 3 S1 2 Silence Timeo...

Страница 7: ...put Pin 4 Select A Input Pin 5 Error Reset Pin 6 Status Common Pin 7 Status B Selected Pin 8 Status A Selected Pin 9 Auto Mode Status Command input pins 2 3 4 5 require a momentary closure to ground Status connections open collector outputs which require a 5 VDC pull up Remote Control RS 232 Connection Diagram 7 ...

Страница 8: ...ush buttons Switcher Selection Error Reset Auto Manual Mode Operation Select Volume Up Down Front Panel Indicators Sample Rate Lock Loss Error Flags Channel Status Auto Manual Mode Power Requirements 100 240 V A C 0 25A 50 60 Hz Operating Environment 0 60 Degrees Celsius Non Condensing Atmosphere Physical 19 W X 8 D X 1 75 H Mounted via Standard E I A 19 rack one rack unit occupied Weight 8 LBS FC...

Страница 9: ...de of the carton Any packages received without such R A number will be refused Note freight collect shipments will also be refused When the unit has been received inspected and tested the customer will receive a report of the findings along with a quotation for recommended repairs which are found falling outside of the standard warranty Units returned for in warranty repairs which are found not to...

Отзывы: