BBV BBV RX100 Скачать руководство пользователя страница 3

Installation Manual – Rx100 Interface Edition 1.5

March 2001

Page 3

1. PRE-INSTALLATION CHECKS AND SAFETY PROCEDURES

UNPACKING
Check Packaging -

 Upon taking delivery of the unit, inspect the packaging for signs of damage.  If

damage has occurred, advise the carriers and/or the suppliers immediately.

Check Contents -

 Upon taking delivery of the unit, unpack the unit carefully and check that all the

items are present and correct.  If any items are missing or damaged, contact your equipment dealer.

Retain Packaging -

 The shipping carton is the safest container in which to transport the unit.

Retain undamaged packaging for possible future use.

IMPORTANT SAFETY PRECAUTIONS
Read Instructions -

 All relevant safety, installation and operating instructions should be read before

attempting to install, connect or operate the unit.

Retain Instructions -

 All safety, installation and operating instructions should be retained for future

reference.

Heed Warnings -

 All warnings on the unit and in any relevant safety, installation or operating

instructions should be adhered to.

Cleaning - 

Unplug the unit from the power outlet before cleaning.  Do not use liquid cleaners or

aerosol cleaners.  Use a damp cloth for cleaning.

Attachments -

 Do not use attachments not recommended by the product manufacturer as they may

cause hazards.

Water and Moisture -

 Do not expose the internal electronics of this unit to water or dampness; for

example, in an unprotected outdoor installation, or in any area classified as a wet location.  The unit
as supplied conforms to ingress protection rating IP 67.  This rating will be affected by any holes
made in the enclosure. Cable entry points should be protected by the use of suitably rated glands
and/or flexible conduit.  It is not necessary to make further holes in the enclosure for mounting
purposes, as mounting holes are provided at the corners of the enclosure outboard of the seal
between enclosure and lid.

Accessories -

 Do not attach this unit to an unstable stand, bracket or mount.  The unit may fall,

causing serious injury to a person and serious damage to the unit.

Power Sources -

 This unit should be operated only from the type of power source indicated on the

manufacturer’s label.  If you are not sure of the type of power supply you intend to use, consult your
equipment dealer or local power company.  For units intended to operate from battery power or
other sources, refer to operating instructions.

Power Connector -

 This unit is equipped with coaxial power connector mounted at the edge of the

PCB for low voltage power input.  Do not attempt to alter this connector in any way.

Power Cord Protection -

 Power supply cords should be routed so that they are not likely to be

trapped, pinched or otherwise damaged by items in close proximity to them, whether inside the unit
or outside it.  Particular attention should be paid to cords at plugs, connection units and the point of
exit from the unit.

Overloading -

 Do not overload outlets and extension cords, as this can result in fire or electric

shock.

Object and Liquid Entry -

 Never push objects of any kind into the unit, as they may touch

dangerous voltage points or short out parts that could result in fire or electric shock.  Never spill
liquid of any kind on or inside the unit.

Servicing -

 Servicing of the unit should only be undertaken by qualified service personnel, as

opening or
removing covers may expose you to dangerous voltages or other hazards.

Содержание BBV RX100

Страница 1: ...locks Industrial Estate Hailsham East Sussex BN27 3JU UK Tel 44 0 1323 842727 Fax 44 0 1323 842728 Support 44 0 1323 444600 www bbvcctv com Telemetry Interface Installation Guide BBV BBV Model covered Rx100 Dome interface Rx100 Dome Interface ...

Страница 2: ...tter compatibility chart 6 Cable connection method 7 Fig 1 Wago cable connectors Cable types 7 3 Installation 8 Operating voltage 8 Rx100 connections 8 Fig 2 Rx100 pcb connections 4 Setup 9 Diagnostic aids 9 Cable length compensation 9 Fig 3 Launch amplifier 5 System schematic diagrams 10 Fig 4 Integration of dome into conventional system Fig 5 Simple single camera system Appendix A Dome Connectio...

Страница 3: ...e in the enclosure Cable entry points should be protected by the use of suitably rated glands and or flexible conduit It is not necessary to make further holes in the enclosure for mounting purposes as mounting holes are provided at the corners of the enclosure outboard of the seal between enclosure and lid Accessories Do not attach this unit to an unstable stand bracket or mount The unit may fall...

Страница 4: ...facturer are used Safety Check Upon completion of any service or repairs to the unit safety checks should be performed to ensure that the unit is in proper operating condition Pre installation Checks It is recommended that the unit be bench tested prior to installation on the site Safety During Installation or Servicing Particular care should be taken to isolate the dome in order to prevent operat...

Страница 5: ...N Power Requirements 9 12V ac dc plug mounted PSU provided Current Consumption 100mA maximum Features Serial data output either RS232 RS485 RS422 4 alarm inputs 1 N C alarm output Up to 16 pre set positions can be stored within the Rx100 Relay capable of switching 1Kw of lighting Engineering Facilities Unit auto tunes to the coaxial telemetry signal LED readout for continual system status Video la...

Страница 6: ... Pelco SD 5 Turbo pan tilt mode can be used by adding option link to J6 This mode is always used when driving to a pre set position Dome Aux 2 output can be switched using the WASH feature available on Tx400 Tx400DC Tx500 Tx1000 Tx1000DC transmitters Full dome menu accessible Tx400 400DC 1 Tx500 Tx1000 1000DC WASH Star MD 100 The dome provides an autopan feature between pre set positions 7 8 which...

Страница 7: ...ERFACE Although BBV do not specify any particular type manufacturer or supplier of cables the following ESD Electronic Services 01279 626777 cables have been used successfully for production and testing ESD Part Number Description 0222586G Co Ax Cable Minimum Specification 100 m RG59B U ESD radio frequency coax cable to BS2316 and MIL C 17 1 0 58mm copper covered steel wire conductor with solid po...

Страница 8: ... J7 FCC68 Alarm 1 contact in J3 A1 GND Grey WAGO optional if alarm input required Alarm 2 contact in J3 A2 GND Grey WAGO optional if alarm input required Alarm 3 contact in J3 A3 GND Grey WAGO optional if alarm input required Alarm 4 contact in J3 A4 GND Grey WAGO optional if alarm input required Alarm contact out J3 AOUT AOUT Grey WAGO optional if alarm input required Lighting relay J5 Coloured W...

Страница 9: ... amplifier with two variable controls situated close to the BNC connectors Lift and Gain These are pre adjusted for a cable distance of 500m of RG59 are and adjustable to compensate for video detail or signal losses if and when longer or shorter cable lengths are used to connect the telemetry transmitter to the interface Fig 3 Launch Amplifier The purpose of each control is GAIN varies the overall...

Страница 10: ...Twisted Pair OPTIONAL 2ND KEYBOARD B B V 300 LENS LENS IRIS FOCUS ZOO M PROGRAM AUTOPAN 9 10 11 12 13 14 15 16 8 7 5 6 4 3 1 2 CAMERA SELECT MONITOR PAN TILT PRESET PATROL SEQ B B V 1000 B B V 300 LENS LENS IRIS FOCUS ZOO M PROGRAM AUTOPAN 9 10 11 12 13 14 15 16 8 7 5 6 4 3 1 2 CAMERA SELECT MONITOR PAN TILT PRESET PATROL SEQ B B V 1000 video in coax Tx1000 8 or 16 Base Unit video out coax TxLD Tx...

Страница 11: ...me connections Page A 1 Appendix A Dome connection details Alltec Apollo A 2 JVC TK C675E A 3 Mark Mercer D250MPT A 4 Panasonic WV CSR400 B A 5 Panasonic WV CSR600 B A 6 Now Fully supported Pelco SD 5 Spectra A 7 Star MD 100 A 9 ...

Страница 12: ...ts the camera resulting in a temporary loss of video When the video image has reappeared the dome is ready for operation FEATURES The Rx100 provides the following features Tx400DC Tx1000DC Pan Tilt Joystick Joystick Zoom Zoom keys Zoom keys Focus Focus keys Holding for 2 seconds enables auto focus Focus keys Holding for 2 seconds enables auto focus Save pre set Hold PROGRAM tap 1 8 Press PROGRAM t...

Страница 13: ...ick Zoom Zoom keys Zoom keys Focus Focus keys Focus keys Save pre set Hold PROGRAM tap 1 8 Press PROGRAM then 1 then 1 16 Goto pre set Tap 1 8 Hold PRESET tap 1 16 Start Patrol 1 Hold PROGRAM tap AUTOPAN Hold PATROL tap 1 Start Patrol 2 Hold PROGRAM tap LIGHTS Hold PATROL tap 2 Camera Shutter Speed Hold tap 1 cycle 1 60 1 100 1 1000 1 2000 1 10000 sec Hold tap WASH cycle 1 60 1 100 1 1000 1 2000 1...

Страница 14: ...self test FEATURES The Rx100 provides the following features Tx400DC Tx1000DC Pan Tilt Joystick Joystick Zoom Zoom keys Zoom keys Focus Focus keys Focus keys Iris when fitted Iris keys Iris keys Save pre set Hold PROGRAM tap 1 8 Press PROGRAM then 1 then 1 16 Goto pre set Tap 1 8 Hold PRESET tap 1 16 Start Patrol 1 Hold PROGRAM tap AUTOPAN Hold PATROL tap 1 Start Patrol 2 Hold PROGRAM tap LIGHTS H...

Страница 15: ... be powered up and is immediately ready for use FEATURES The Rx100 provides the following features Tx400DC Tx1000DC Pan fixed 24º sec Tilt fixed 12º sec Joystick or Keys if none DC Joystick or Keys if none DC Zoom Zoom keys Zoom keys Focus Focus keys Focus keys Iris Iris keys Iris keys Local alarm activation 1 4 will trigger alarm The dome does not have pre set capability therefore head will not m...

Страница 16: ...hen test is completed FEATURES The Rx100 provides the following features Tx400DC Tx1000DC Pan Tilt Joystick Joystick Zoom Zoom keys Zoom keys Focus Focus keys Focus keys Iris when fitted Iris keys Iris keys Save pre set Hold PROGRAM tap 1 8 Press PROGRAM then 1 then 1 16 Goto pre set Tap 1 8 Hold PRESET tap 1 16 Start Patrol 1 Hold PROGRAM tap AUTOPAN Hold PATROL tap 1 Start Patrol 2 Hold PROGRAM ...

Страница 17: ...e control with 9600 baud data rate COMMISSIONING Connect dome and Rx100 as shown Link Rx100 video out to telemetry transmitter using coaxial cable Power up Rx100 first cable LED should blink Next dome can be powered at which point a self test is performed On completion of the test the dome is ready for operation 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 ON OFF ON OFF SW1 Select P type control SW2 Address 1 ...

Страница 18: ...he maximum zoom ratio to 48 The example assumes that a Tx1000 is controlling the Rx100 Please use the keystrokes corresponding to the Tx400dc if that unit is controlling the Rx100 1 Select the camera to be programmed 2 Hold tap WASH The display shows ð ð Camera Line Sync Other Exit 3 Press IRIS OPEN The ð changes to indicating that this function is selected Hold tap WASH 4 The Camera menu is now d...

Страница 19: ... features Tx400DC Tx1000DC Pan Tilt 18º Sec Joystick Joystick Zoom Zoom keys Zoom keys Focus Focus keys Focus keys Save pre set Hold PROGRAM tap 1 8 Press PROGRAM then 1 then 1 16 Goto pre set Tap 1 8 Hold PRESET tap 1 16 Start Patrol 1 Hold PROGRAM tap AUTOPAN Hold PATROL tap 1 Start Patrol 2 Hold PROGRAM tap LIGHTS Hold PATROL tap 2 Autopan between preset 7 8 Tap AUTOPAN after programming preset...

Страница 20: ...ck cabling most commonly due to data cables swapped 2 Dome configuration switches if fitted not set correctly Check configuration Symptom No camera control and lights relay not operating Possible causes 1 Interface not seeing Telemetry signal Check that telemetry is present on video cable using either oscilloscope or adjust v hold on monitor to view frame blanking period and check for black white ...