Sensor Configuration

Without addressing:

Parameter

Step 1

Step 2

Field size
Functionality 
Field geometry

Press [<] briefly
Press [>] briefly
Press [<] and [>] briefly at the same time

Frequency of the flashing 
green LED (1-9 times) indicates 
the current parameter level

5.1

Configuration with keys

Note:

If no key is actuated for 25 s, the programming mode is automatically exited –
however the sensor is still in the configuration mode. The settings made up to
that point are saved.

The status query is to find out what parameters have been set.

5.1.1

Status query with keys

5.2.2

Mode of operation

5.2

Configuration with remote control

A

c

tivation:

–Automatically after the sensor is connected to the supply 

voltage 

or

–Briefly disconnect the sensor from the supply voltage 

or

–Press either key [<] or [>] on the sensor

Exiting:

–Press key              combination 

or

–Automatically after 30 min.

Note:

If no entry is made for 30 s, the connection is ended. The settings 
made up to that point are saved.

1, 2, 3  small

4, 5, 6* medium

7, 8, 9

large

for Merkur version with direction recognition

Level

1*

forwards, mounting height standard

2

forwards, mounting height high

3

backwards, mounting height standard

4

backwards, mounting height high

5

direction recognition OFF, mounting height standard

6

direction recognition OFF, mounting height high

7

fo MTO, mounting height standard (MTO, see chap. 7)

8

fo MTO, mounting height high (MTO, see chap. 7)

1

narrow field

2*

wide field

Changing the functionality from level 6 to level 2:
1) Keep [<] and [>] pressed for 4 s, the green LED blinks once after 2 s, 

once again after 4 s

2) Green LED flashes 6 times and thereby indicates the current parameter level
3) Press the key [<] four times in a row to decrease the parameter level 

(green LED flashes twice and indicates the new parameter level)

4) Press [<] and [>] at the same time

The data transmission to and from the sensor is ensured by an IR interface. The
connection between the remote control and the sensor can only be established
when the sensor is in configuration mode.

The sensor can be configured in two ways:

With keys on the sensor (basic settings)

With the remote control (complete setting options)

With addressing:

1.

Press the     start key

1.

Cover the IR interface of the 
remote control with your hand

2.

Press the     start key 

flashes

3.

Release the IR interface 
(remove hand)  

4.

Press the corresponding numerical 
key (     to     )

– G and one of the keys 1 to 4 light up:

Connection successfully established

– G flashes:

Connection not established

Activate configuration mode

Hold remote control closer to the sensor and point directly at it

Check batteries in remote control

– No keys light up

Check/replace batteries in remote control

5.2.3

Setting / changing parameters

Keep the door open manually for 15 min. when making settings.
Afterwards, the door will close if no object is in the detection area

Door closes when no object is in the detection area, afterwards
standard operation

Configuration mode is ended, door closes when no object is in the
detection area, afterwards standard operation

After the connection has been successfully established, the parameters of the
sensor can be changed.

* Fa

c

tory setting

General procedure

[>]

[<] 

Changing the field size: Press [<] and [>] for 2 s

Changing the functionality: Press [<] and [>] for 4 s

for Merkur version without direction recognition

1*

mounting height standard

2

mounting height high

Changing the field geometry:Press [<] and [>] for 6 s

Example

Restore factory settings: Press [<] and [>] for 8 s

Configuration mode

+     

A

3

Establishing the connection

Each sensor can be assigned an address (1*, 2, 3 or 4). Different addresses are
necessary when several sensors are within the range of a remote control.

Address 1*

Address 2

Address 3

Address 4

5.2.1

Sensor addressing

G

G

G

1

4

+     

A

1

+     

A

2

+     

A

3

Numerical keys     to

1

9

IR interface (infrared)

Control keys     to

A

F

Start

G

1) Keep [<] and [>] pressed for a corresponding length of time, every 2 s the 

green LED will flash once

2) Frequency of the flashing green LED (1–9 times) indicates current parameter level
3) The parameter level can be decreased or increased with [<] and [>] 

respectively

4) Press [<] and [>] briefly to exit the programming mode (settings are saved)

Level

Level

Level