Parameter

Dire

c

tion re

c

ognition     :

Merkur 2 ES

Merkur 2

Field size

Relay hold interval

Output signal

SMD fun

c

tion

Mounting height

Cross traffi

c

Interferen

c

e suppression

SMD field size

Field geometry

C

1

+     *

+     

C

2

+     

C

3

+     

C

4

+     

C

5

+     

C

6

Standard

ON, forwards

6

1 s

A

c

tive

Off 

Up to 3 m

Low

Off 

1

Wide

Pavement

ON, forwards

7

0.8 s

A

c

tive

Off 

Up to 3 m

Medium

Off 

1

Narrow

Retirement home

OFF

6

2 s

A

c

tive

De

c

reasing, 2 s 

Up to 3 m

Off 

Off 

5

Wide

Entry hall

ON, forwards

6

0.2 s

A

c

tive

Off 

Up to 3 m

Low

Off 

1

Narrow

Supermarket

ON, forwards

9

1.5 s

A

c

tive

De

c

reasing, 2 s

3–4 m

Off 

Off 

5

Wide

High mounting

ON, forwards

9

1 s

A

c

tive

Off 

3–4 m

Medium

Off 

1

Wide

3 m

(9.84')

>

Key code

Key

code

Parameter

Level

Short description

Enhanced functions

1*– 6 

Predefined settings for standard
applications (see table)

Specified values measured with mounting height 2.2 m and inclination angle 35°.

SMD = Slow motion detection: Very small (quasi-static) movements are detected
as soon as the sensor is activated. Only when no more movements are registered
during the set monitoring period does the sensor relay the corresponding signal
to the door controller. The sensitivity during this monitoring period can be set to
decreasing or constant.

Min. 1.1 x 0.6 m (WxD)     
Max.4.7 x 1.7 m (WxD)

* Fa

c

tory setting

Enhanced functions

Configuration of individual parameters

Field size      / field geometry

D

+     

F

8

Depending on the field geometry (wide/narrow field), the field size can be set
correspondingly. 

Narrow
field:

Wide
field:

SMD function               and SMD+

+     

F

3

SMD+: Triggers the sensor when very slow movements occur.
In this way, even objects < 5     (35° inclination angle) that are
not detected with the normal detection area are reliably
identified (retirement home setting). In order to prevent the
door from being kept open too long, the SMD+ field is half as
large as the detection area.

SMD field size

+     

F

7

The SMD field sizes approximately correspond to those of the detection area,
i.e. 

The CTM prevents a door from being inadvertently opened by peoply who only
walk past it but do not want to enter. 

+     

D

5

+      +      

~

F

7

5

Cross traffic masking CTM

+     

F

5

Optimum sensor settings:
– Narrow field
– Inclination angle 30°–45°

5.2.5

Status query with remote control

The status query is to find out what parameters have been set. For this to take
place, the connection to the sensor has to be established and the corresponding
key code has to be entered. Next, a numerical key lights up that indicates the
respective parameter level.

cm

s

+     

F

4

C

B

D

+     

F

8

+     

F

1

+     

F

2

+     

F

3

+     

F

7

+     

F

5

+     

F

6

B

D

+     

F

1

+     

F

2

+     

F

3

+     

F

4

+     

F

5

+     

F

6

+     

F

7

+     

F

8

~

5.2.4

Explanation of individual parameters

Recommendation: 

First, select the enhanced function that is closest to the requirements and then change the parameter levels correspondingly.

D

W

D

W

Min. 0.7 x 0.6 m (WxD)     
Max. 2.7 x 1.9 m (WxD)

Direction recognition
(only with Merkur 2
ES)

Off
Backwards
Forwards
Forwards with MTO (see chap. 7)

1
2
3*
4

2*
1
2*

1 – 3 
4 – 6* 
7 – 9 

1
2
3

4*

5
6
7
8
9
1*

2

1*

3
4
5

6
7
8

9

1*– 3
4 – 6
7 – 9

1

2*– 3
4 – 6 
7 – 9

1

2* 

On

Prevention of possible 
spurious tripping by fluorescent 
tubes. 

Off

Off
Low
Medium
High

Small
Medium
Large

Off

0.5 s
1.0 s

Decreasing sensitivity

1.5 s
2.0 s

0.5 s
1.0 s

Constant sensitivity

1.5 s

2.0 s

(plus SMD+)

Active: The relay picks ups when 

a detection takes place

Passive: The relay drops out when 

a detection takes place

Small
Medium
Large
0.2 s
0.5 s

Short

0.8 s
1.0 s
1.5 s

Medium

2.0 s
2.5 s
3.0 s

Long

4.0 s

Narrow field
Wide field

High (3–4 m)
Standard (up to 3 m) 

Mounting height

Field geometry

Field size

Output signal

Relay hold interval

SMD function

SMD field size

CTM
(cross traffic 
masking)

Filter for 
interference 
suppression