Network Menu Options 
Select each menu option, press ‘Enter, then select next option and press ‘Enter’, i.e. {Network Status: (C/1), 
type ‘C’ (Configure) at prompt and press ‘Enter’, type ‘1’ (Status) at prompt, and press ‘Enter’. 

 
PD Unit (2,1): (

1

Type 

config

 

Manage Users: (

1

Change Outlet Name: (

2

Enable/Disable Confirmation: (

3

Enable/Disable Status Menu : (

4

Change Unit ID: (

5

Change Alarm Threshold: (

6

Change Display Orientation: (

7

Change Redundant Power Switch Back mode/time; 

{redundant power only}

: (

8

Change Redundant Power Switching Brownout Voltage Levels; 

{redundant power only}

: (

9

Type 

help

PD Unit (2,2): (

2

Network Status: (

S

Network Configure: (

C

Status: (

C/1

Serial Port Configuration: (

C/2

Handshaking: (

C/2/1

Baud Rate: (

C/2/2

Word Size: (

C/2/3

Stop Bits: (

C/2/4

Parity: (

C/2/5

RTS Line Driver Inactive State: (

C/2/6

DTR Line Driver Inactive State: (

C/2/7

Serial Port Device Name: (

C/3

Attention Character: (

C/4

Disconnect Timeguard: (

C/5

Connect Port ID Echo: (

C/6

Disable Port ID Echo: (

C/6/1

Use Module, Port Number: (

C/6/2

Use Device Name: (

C/6/3

Login Setup: (

C/7

Access Control: (

C/7/1

Radius Configuration: (

C/7/3

TACACS Configuration: (

C/7/4

Network Port Configuration: (

C/8

) with IPv6 

IPv4 Configuration: (

C/8/1

IPv6 Configuration: (

C/8/2

Inactivity Timeout: (

C/8/3

Carriage Return Translation: (

C/8/4

Break Length: (

C/8/5

DHCP Enable/Disable: (

C/8/6

Telnet Enable/Disable: (

C/8/7

SSH Enable/Disable: (

C/8/8

SSH Host Key Generation: (

C/8/9

IP Filter Configuration: (

C/8/10

SNMP Configuration: (

C/8/11

Web Server Configuration: (

C/8/12

Module Name: (

C/9

RPC Management: (

C/10

 Temperature Alarm Threshold: (

C/10/1

Содержание MSP Series

Страница 1: ...2019 COPYRIGHT 2019 Bay Technical Associates Inc 1 1 2019 MSP and MSPr Redundant Series QUICK START ...

Страница 2: ...ig and press Enter You should see a menu similar to Figure 4 Select number for the Manage Users option You should see a menu similar to Figure 5 7 IMPORTANT NOTE the first user added will be the ADMIN user Type A and press Enter Type the name of the admin user The name is case sensitive 8 Select the user number You should see the user in the menu similar to Figure 6 9 Select Add Outlet s to add a ...

Страница 3: ...r N to decline changes 13 After Accepting or Declining Changes you should get the Network Access Menu Figure 7 14 Select Unit reset to update the external connections Once the reset is completed 1 minute connect the Baytech device to your network using an Ethernet cable 15 If you disabled the DHCP in step 11 you should see a menu similar to Figure 13 16 Select the IP Address option and type the as...

Страница 4: ...SP 05 Status cr MSP 05 Status Config cr Enter configuration mode Current cr Display True RMS Current Voltage cr Display True RMS Voltage Power cr Display Average Power Clear cr Reset the maximum detected current Temp cr Read current temperature Logout cr Logoff Logoff cr Logoff Exit cr Logoff Password cr Changes the current user password Whoami cr Displays the current user name Unitid cr Displays ...

Страница 5: ...wing message Configuration mode in use A user in the other port is in the Configuration menu The User Menu allows the admin user to add and delete users change passwords and change the outlet list that displays a user s access to prescribed outlets Select Manage Users from the configuration menu and the following menu appears if the unit has been reset or initial setup User Assigned Outlets C1 1 C...

Страница 6: ...hoices Example Turn off all outlets Y N Enable Disable Status Menu Enables Disables whether outlet status menu is displayed Change Unit ID Allows the user to change the name of the unit The defaulted is something similar to MSP05 Allows the user to personalize or customize name or location up to 31 alphanumeric characters Change Alarm Threshold The Alarm Threshold is the value set that sounds the ...

Страница 7: ...eby preventing unwanted port disconnection Connect Port ID Echo 6 Echo port name or module port Login Setup 7 Login Menu Serial Telnet Radius TACACS access control manage users Network Port Configuration 8 Network Port IP Address Module Name 9 Change name of module MSP Management 10 Set up Voltage Current Sensor threshold Firmware Config Download 11 Update Firmware SSL Configuration files Exit X C...

Страница 8: ...bnet Mask and Gateway Address or enable the DHCP The Changes must be saved and the module reset for network changes to take effect Network setup Ethernet Address 00 C0 48 00 01 FD IP Address 70 150 140 89 Subnet Mask 255 255 255 224 Default Gateway 70 150 140 65 Connection Inactivity Timeout mins Disabled Carriage Return Translation Enabled Break Length msecs 350 DHCP is Disabled Telnet is Enabled...

Страница 9: ...21 6 Load RMS Voltage 121 5 Total kW h 33956474 Circuit True RMS Peak RMS Average Volt Breaker Current Current Power Amps CKT1 0 1 0 3 0 18 Int Temp 97 7 F Switch 1 Open 2 Open 1 MOD 1 Outlet 1 On Locked 2 MOD 1 Outlet 2 On Locked 3 MOD 1 Outlet 3 On Locked 4 MOD 1 Outlet 4 On Locked 5 MOD 1 Outlet 5 On Locked 6 MOD 2 Outlet 1 On Locked 7 MOD 2 Outlet 2 On Locked 8 MOD 2 Outlet 3 On Locked 9 MOD 2...

Страница 10: ...ed to set the Secondary to primary value Disable switch back to primary Y N N Current delay switch back to primary source time is 0 minimum 0 Seconds Change delay switch back time Y N y Enter seconds 0 6500 Enable switch back to primary Y N y Current delay switch back to primary source time is 0 minimum 0 Seconds Change delay switch back time Y N y Enter seconds 0 6500 1 Manage Users 2 Change Outl...

Страница 11: ...dshaking C 2 1 Baud Rate C 2 2 Word Size C 2 3 Stop Bits C 2 4 Parity C 2 5 RTS Line Driver Inactive State C 2 6 DTR Line Driver Inactive State C 2 7 Serial Port Device Name C 3 Attention Character C 4 Disconnect Timeguard C 5 Connect Port ID Echo C 6 Disable Port ID Echo C 6 1 Use Module Port Number C 6 2 Use Device Name C 6 3 Login Setup C 7 Access Control C 7 1 Radius Configuration C 7 3 TACACS...

Страница 12: ...F C 10 7 RPC Cascade Mode C 10 8 Power Factor Threshold C 10 9 Firmware Config Download C 11 Enable Firmware Upgrade C 11 1 Enable SSL Cert Upload C 11 2 Enable Configuration File Upload C 11 3 Restore Configuration Defaults C 11 4 Get Current Configuration File C 11 5 Display Configuration Error Log C 11 6 Enable Rel Ctl Firmware Upgrade C 11 7 Unit Reset RU Logout T End of Quick Start Manual ...

Отзывы: