98
If you are connecting to another BayTech product (such as Tran-x),
please refer to
Appendix A.3
for the recommended cable pinouts.
A.2.2
EIA-422 XON/XOFF
HANDSHAKING
When connecting an EIA-422 device to the PS-4C or PS-4E using
XON/XOFF handshaking, the cable required to connect the two
devices must have TX+ wired to RX+ (and vice versa) and TX-
wired to RX- (and vice versa). Please see
Figure 14
below.
PS-4C or PS-4E Equipment
(EIA-422) Connections
RJ-45
1
2
3 TX+ RX+
4 TX- RX-
5 RX- TX-
6 RX+ TX+
7
8
Figure 14
: EIA-422 Connection using XON/XOFF Handshaking
If you are connecting a device which is not another BayTech
product, you must refer to the operator's manual for your
equipment to determine which pins are defined as TX+, TX-, RX+,
and RX-.
If you are connecting to another BayTech product (such as Tran-x),
please refer to
Appendix A.3
for the recommended cable pinout.