background image

 

DS71-MD4 Serial host and 56k Modem 

18 

 

 

RTS/DTR Line Driver Inactivity State 

RTS (Request to Send)/ DTR (Data Terminal Ready) is normally used in conjunction with an external 
modem. With no modem the RTS and DTS 

default state is High.

 

 

Select “RTS Driver State” the DS displays the following: 

 

 

 

Select “DTR Driver State” the DS displays the following: 

 

 

Port Device Name 

Select a port and type the new name: 

 

 

Port Select Code  

The Port Select Code is an ASCII character string sent by the host terminal to the module to select an 
I/O port on a DS74 peripheral module. The Port Select Code’s factory default setting is 

$BT

 and is 

programmable up to 8 characters as shown. 

 

 

Attention Character  

Pressing the Attention Character 5 consecutive times will access the network main menu. 

The Default is 

a semi-colon (;)

. Select this option to change the attention character. The DS displays the following: 

 

 

 

NOTE:

 If you change the attention character and forget which letter or symbol you selected, the 

attention character will not echo if you are typing the correct character. You can type each 
character/symbol on the keyboard to find it, or reset the module to factory default to get the 
semi-colon back. 

Output Flow Control (Xmit) - Xon/Xoff is (  Off ) 
Stop/Restart Output Upon Receiving of Xoff/Xon ? (Y/N) : 

 

Input Flow Control (Recv) - Xon/Xoff is (  Off ) 
Xoff/Xon sent based on Buffer - Full/Empty condition ? (Y/N) : 

RTS Line Driver Inactive State is: High
High ? (Y/N, CR for no change): 

DTR Line Driver Inactive State is: High
High ? (Y/N, CR for no change): 

Enter New Port Name (Max. 16 characters):
or press ENTER for no change ................: 

Port Select Code :$BT 
Change It ? (Y/N) : 

Attention Character :; 
Change It ? (Y/N) : 

Содержание DS Series

Страница 1: ...DS Series Manual DATA SWITCH DS71 MD4 Host Modem Module BayTech Manual Publication Revision May 2008 ...

Страница 2: ...l Associates Inc BayTech is a registered trademarks of Bay Technical Associates Inc Windows 2000 Windows XP are products and registered trademark of Microsoft Corporation Tera Term is a product and registered trademark of Vector Inc ...

Страница 3: ...ation Menu 13 Host Module Configuration 13 Configuration Status 14 Serial Port Configuration 16 Port Device Name 18 Port Select Code 18 Attention Character 18 Disconnect Timeguard 19 Connect port ID Echo 19 Login Setup 19 Header 20 Access Control 20 Menu 20 Manage Users 20 Auto Connect 22 Dial Back Number 22 Assign User Ports 23 Local Modem Option 24 Ring to Answer 24 Connectivity Timeout 24 Inact...

Страница 4: ... is subject to change without notice The statements configurations technical data and recommendations in this document are believed to be accurate and reliable but are presented without express or implied warranty Users must take full responsibility for their applications of any products specified in this document The information in this document is proprietary to Bay Technical Associates Inc In t...

Страница 5: ...1 MD4 modem option has priority over the EIA 232 serial port If a serial port user is in configuration mode or connected to a DS74 I O port when a modem connection is established the serial port user will be booted off allowing the remote user to communicate with the DS unit External Modem Connection Using the 25MRJ45MD 6 adapter or other applicable adapter and the RJ08X007 crossed cable connect t...

Страница 6: ...adapter to your PC 2 Connect the supplied rollover flat cable RJ08X007 to the adapter and to the EIA232 serial port on the Baytech DS71 MD4 Module 3 Use terminal emulation software to access the unit i e Microsoft Hyper terminal Set the PC serial port configuration to the following 9600 bps 8 data bits 1stop bit and no parity 4 If you get only a blinking cursor Press Enter If still only a blinking...

Страница 7: ...is is not an initial set up and Password has already been enabled you are prompted to login After logging in successfully invoke the main menu by sending the attention character five times NOTE Password feature is case sensitive Default is user password is root baytech Main Menu The following Header and Menu appears or similar Figure 1 Select option C for the configuration menu Select the DS71 MD4...

Страница 8: ...S71 MD4 Data Switch Series V90 Modem Host Module Revision F 1 01 01 Module 2 Status 1 Serial Port Configuration 2 Port Device Name 3 Port Select Code 4 Attention Character 5 Disconnect Timeguard 6 Connect port ID Echo 7 Login Setup 8 Local Modem Option 9 Unit ID U Exit X CR Enter Request Login Setup Header 1 Enable Disable header for each menu Access Control 2 Enable Disable Network Serial port us...

Страница 9: ... Number This allows user to dial in hang up and the unit dials the assigned number back when using a secure phone line Assign User Ports This option allows the administrator to limit users port access Figure 5 User Management Menu admin 1 Add New User A Delete User D Change User C To change user password enter number of user Enter Request 1 Assigned User Ports M3 M4 M5 User Name 1234 1234 1234 2 j...

Страница 10: ...e State High 12V when power is applied Used as a handshake line to enable disable the receiving of characters 2 GND Signal Ground 3 RTS Out Handshake Line Driver Inactive State High 12 V when power is applied Not used to enable disable 4 TX Out Transmit Data Out 5 RX In Receive Data In 6 DSR In Handshake In 12V when not used 7 GND Signal Ground when Jumper JP6 2 is connected to JP6 3 In order for ...

Страница 11: ...terminal COM ports Signal RS 232 Port DS RS 232 Port RPC COM Port DE 9 Pin COM Port DB 25 Pin Signal DTR 1 1 4 20 DSR GND 2 2 1 GND RTS 3 3 7 5 CTS TXD 4 4 3 2 RXD RXD 5 5 2 3 TXD DSR 6 N C 6 6 DTR GND 7 7 5 7 GND CTS 8 8 4 RTS DTR 4 DCD DCD 8 1 8 DTR RI 9 22 Adapters 9FRJ45PC With Cisco Interface 9FRJ45PC 1 Without Cisco Interface ...

Страница 12: ...DS71 MD4 Serial host and 56k Modem 12 RJ08X007 Figures 1 and 2 provide visual representation of an RJ 45 receptacle and plug ...

Страница 13: ...lowing pages define each line of the configuration menu Changes take effect immediately Host Module Configuration Enter the number that corresponds with the Host Module followed by a cr and the Host Module responds without the option description Module 2 admin on Host EIA 232 Device A 2 1 1 Device B 2 2 2 Device C 2 3 3 Device D 2 4 4 DS RPC 5 1 5 Configuration C Module setup I O Modules Reset RM ...

Страница 14: ...1 01 Module 2 Status 1 Current status of DS71 MD4 module Serial Port Configuration 2 Change port config 9600 8 1 none Port Device Name 3 Change the name of the device Port Select Code 4 Non Menu ASCII code to select DS74 port Attention Character 5 get Main Menu Disconnect Timeguard 6 Delay to see if more data after char Connect port ID Echo 7 Enable echo module port device name Login Setup 8 Mange...

Страница 15: ...signed User Ports M3 M4 M5 User Name 1234 1234 1234 1 admin 1234 1234 1234 User Dialback Phone number User Name Phone number Dialback 1 admin Disabled Dialback Delay 10 seconds Access Control Serial Port access 1 Prompt for User Name Disabled 2 Prompt for Password Disabled Modem Port access 3 Prompt for User Name Disabled 4 Prompt for Password Disabled Auto Connect Module Port User Name M P Auto 1...

Страница 16: ...600 Word Size The word size is the measurement of the actual data bits in a transmission Which setting you choose depends on what information you are transferring For example standard ASCII has values from 0 to 127 7 bits Extended ASCII uses 0 to 255 8 bits If the data being transferred is simple text standard ASCII sending 7 bits of data per packet is sufficient for communication A packet refers ...

Страница 17: ...able the device to determine if noise is corrupting the data or if the transmitting and receiving devices clocks are out of sync With no parity selected it s assumed that there are other forms of checking that will detect any errors in transmission No parity also usually means that the parity bit can be used for data speeding up transmission In modem to modem communication the type of parity is co...

Страница 18: ...ecutive times will access the network main menu The Default is a semi colon Select this option to change the attention character The DS displays the following NOTE If you change the attention character and forget which letter or symbol you selected the attention character will not echo if you are typing the correct character You can type each character symbol on the keyboard to find it or reset th...

Страница 19: ...the user to enable or disable the Header Access Control Menu Manage Users Auto Connect Dial Back Number and Assign User Ports Disconnect Time Guard Disabled Enable Y N CR for no change BAYTECH For further information check http www baytech net DS71MD4 Device name Port echo or 02 1 Module and Port Number echo Disable Port ID Echo 1 Use Module Port Number 2 Use Port Name 3 Login Setup Header 1 Enabl...

Страница 20: ...actory defaults The host module confirms the option you selected to change Menu This allows the admin to enable or disable the Menu on start up If disabled the header appears upon login without the main menu To invoke the main menu when disabled enter the attention character five times The default user and password is admin baytech all lower case Manage Users This option allows the administrator t...

Страница 21: ... the admin user the Module responds with an input error message Type the number of the user to be deleted and press cr A successful deletion the Module responds with User Menu minus the deleted user Change User Select C from the User Management Menu and type the number of the user to edit User Management Menu admin 1 Add New User A Delete User D Change User C To change user password enter number o...

Страница 22: ...hen using a secure phone line Select a user number and the module displays the following Select Phone number option to enter a phone number assigned to the user Select Dialback option to enable or disable the dial back feature Default is Disabled User Name M P Auto 1 admin 1 1 Disabled Dial in Auto Connect Port 1 Enabled Disable 2 Exit X CR Enter Request 1 Enter Auto Connect Module 1 to 9 2 Enter ...

Страница 23: ...odule displays the user s assigned ports Add All Ports Dialback Delay 10 seconds Enter Dialback Delay 1 to 60 Assigned User Ports M3 M4 M5 User Name 1234 1234 1234 2 johnt x234 123x 1xx4 Add Port s 1 Adds individual ports Remove Ports s 2 Removes individual ports Add All Ports 3 Add All Remove All Ports 4 Remove All Exit X CR Enter Request 1 Enter Module and Port number in format M P or M P 0 All ...

Страница 24: ...nectivity Timeout The timer starts when the modem answers DCD goes high The modem will disconnect regardless of activity when time runs out Default setting is 60 minutes The module displays the following Inactivity Timeout This option sets the time the modem will automatically disconnect if there is no activity equaling the programmed amount of time 1 to 120 minutes Default setting is 0 disabled S...

Страница 25: ...ections NOTE You must be connected to the DS71 MD4 module to reset the unit Resetting the unit does not return user selections to their default settings Select Reset Unit followed by cr The module resets the unit and displays Allow approximately 10 seconds for the unit to reset It should state something similar to Troubleshooting Functional Solutions 1 No menu serial port a DS power is on and cabl...

Страница 26: ...the user refer to Login Setup Assign User Ports 5 Verify DS chassis Host Module and DS74 is functioning A rollover cables pin out 1 8 2 7 3 6 4 5 5 4 6 3 7 2 8 1 and a 9 pin adapter 9FRJ45PC 1 and Ethernet or Modem cable a Set up the Host module with modem or Ethernet cables for normal operations b Connect the rollover cable and adapter from the PC to a DS74 port c Create a Modem Ethernet session ...

Страница 27: ...omer is responsible for properly packaging the product and for shipping costs for returns The customer is liable for loss or damage to the product during shipping as well as any other fees or charges associated with transporting the product back to BayTech BayTech will pay return costs for delivery within the Continental United States All repair and return shipments must be approved by BayTech and...

Страница 28: ...pproved by BayTech management Contact BayTech for further details on this Technical Support BayTech offers Tech Support for the lifetime of the product A staff of Applications Engineers is on duty to assist with installation set up or operation issues Support is available from 8 00 a m to 5 p m CST or CDT Monday through Friday at the phone numbers or website provided below Please have the followin...

Страница 29: ...ore servicing or dismantling Return Authorization Process 1 Contact BayTech to get a Return Authorization RA Number IMPORTANT BayTech will not accept any returns without an RA number 2 Package the unit carefully in its original packaging or similar packaging The warranty does not cover damage sustained during shipment Enclose a letter with name address RA number daytime phone number and descriptio...

Отзывы: