DS-RPC OWNER’S MANUALAPPENDIX D__________________________________________________________________________________________
81
APPENDIX D - DRAWINGS
DS71 MECHANICAL LAYOUT
Страница 1: ...OWNER S MANUAL ________________ DS RPC DATA SWITCH POWER CONTROL FOR MODELS DS2 RPC DS4 RPC Including the DS71 DS71 MD2 DS74 DS73 Modules BayTech Manual Publication U140A124 01 August 1998 ...
Страница 2: ...M IBM PC IBM PC AT IBM PC XT are products and registered trademarks of International Business Machines Corporation Hewlett Packard LaserJet is a product and registered trademark of the Hewlett Packard Company PROCOMM PLUS is a product and registered trademark of Datastorm Technologies Inc Windows 95 is a product and registered trademark of Microsoft Corporation ...
Страница 3: ...call toll free from anywhere in the United States using 1 800 523 2702 or contact us at our Web Site www baytechdcd com BayTech manufactures many remote site management products data switches data collection multiplexers remote power controllers and peripheral print sharers If you would like information on any of these products please contact BayTech Customer Service at the numbers previously list...
Страница 4: ...specified in this document The information in this document is proprietary to Bay Technical Associates Inc In the interest of improving internal design operational function and or reliability Bay Technical Associates Inc reserves the right to make changes to the products described in this document without notice Bay Technical Associates Inc does not assume any liability that may occur due to the u...
Страница 5: ...ARING THE INSTALLATION SITE 11 POWER 11 POWER ON OFF STATE 12 POWER UP SEQUENCE 12 CIRCUIT BREAKER 12 CABLING 13 RJ 45 CABLES AND ADAPTERS 13 MODEM CONNECTIONS 16 DETAILED OPERATION AND CONFIGURATION 18 CONNECTING TO THE DS SERIES 18 EIA 232 SERIAL CONNECTION 18 INTERNAL MODEM CONNECTION DS71 MD2 ONLY 19 EXTERNAL MODEM CONNECTION 19 10BASE T NETWORK PORT CONNECTION 20 OPERATION 21 ACCESSING MAIN M...
Страница 6: ...XOFF 46 CONNECTIVITY TIMEOUT 47 ESCAPE CHARACTER 48 UNIT ID 49 I O MODULES RESET 49 UNIT RESET 49 MENU DRIVEN SELECTION 50 ACCESS CHARACTER STRING 50 DS74 CONFIGURATION 51 SERIAL PORT CONFIGURATION 52 PORT DEVICE NAME 52 DS73 CONFIGURATION 53 MODULE IP ADDRESS 54 DIAL UP ADDRESS 55 SUBNET MASK 56 GATEWAY 57 PRIMARY DNS 57 SECONDARY DNS 58 PRIMARY NBNS 59 SECONDARY NBNS 59 USER NAME 60 PASSWORD 60 ...
Страница 7: ..._____________ vii TECHNICAL SUPPORT 69 EQUIPMENT SETUP 70 REPACKAGING SHIPPING AND RETURNING TO THE FACTORY 71 FCC RADIO FREQUENCY INTERFACE STATEMENT 72 APPENDIX A SPECIFICATIONS 74 APPENDIX B MODEM COMMANDS 76 APPENDIX C WINDOWS 95 TUTORIAL 78 APPENDIX D DRAWINGS 81 APPENDIX E ASCII CHARACTER DEFINITION 85 INDEX 86 ...
Страница 8: ......
Страница 9: ...s Used for accessing remote equipment or simply switching between multiple ports the DS RPC provides a full duplex connection between the host and up to 12 peripherals In a typical application the host module connects to a local or remote computer and the peripheral port modules connect to devices such as routers hubs servers and Data Service Units DSU s The DS RPC is also compatible with other Ba...
Страница 10: ...l the four power outlets LEDs non volatile storage and data flow between connected modules The data bus is an internal matrix of high speed serial channels that allows independent and simultaneous transmissionof data between modules The DS71 host communications module is a system data controller that directs operations between the base unit system modules and externally connected devices The DS71 ...
Страница 11: ...s to invoke the main menu Default Enter Attention Character 36 Disconnect Time Guard Provides reliable binary data transmission Default Disabled Enable Disable Disconnect Time Guard 37 Port ID Echo Echoes the module number and port number when you connect to the port Default Disabled Enable Disable Connect Port ID Echo 38 Header Unit information that appears upon login Default DS71 or DS71 MD2 Ena...
Страница 12: ...mount of connectivity 5 to 255 minutes before modem disconnects Default 60 minutes Enter timeout in minutes Enter 0 to disable 47 Escape Character Allows ASCII characters to be interpreted as commands instead of data Default 43 Enter the character you wish to use as an escape 48 Unit ID Unique ID for DS Series unit Default DS71 or DS71 MD2 Enter unit ID 48 DS74 PERIPHERAL I O MODULE Serial Port Co...
Страница 13: ... the Subnet Mask in dotted decimal format 0 0 0 0 56 Gateway Consists of four bytes each byte ranging from 0 to 255 Default 0 0 0 0 Enter the Gateway in dotted decimal format 0 0 0 0 57 Primary DNS Primary Domain Name System address Default 0 0 0 0 Enter Primary DNS Address 57 Secondary DNS Secondary Domain Name System address Default 0 0 0 0 Enter Secondary DNS Address 58 Primary NBNS Primary Net...
Страница 14: ...rial port of your computer to the RJ 45 port labeled EIA 232 on the DS71 or DS71 MD2 module Load serial port communications software Set serial communications parameters to 9600 bps 8 data bits 1 stop bit and no parity OPERATION Accessing Main Menu Power on the DS RPC The following header and main menu appears if using the DS71 Data Switch Series F 2 01 Bay Technical Associates Unit ID DS71 Port S...
Страница 15: ... 3 Device D 2 4 4 DS RPC 3 1 5 Configure C I O Modules Reset RM Unit Reset RU Exit X Logout T Enter Request NOTE These menus depict a typical DS2 RPC setup The DS4 RPC may have more menu items depending on the setup If this is not an initial set up and Password has already been enabled you are prompted to login After logging in successfully access the main menu by sending the attention character f...
Страница 16: ...re connected properly Also verify the serial communication parameters are correctly configured Controlling Receptacles To set or change the status of the receptacles enter one of the following commands ON n OFF n REBOOT n where n is the outlet number you want to command Entering an outlet number of 0 sends the command to all outlets Reboot only works on outlets which are in the ON condition DS RPC...
Страница 17: ...____________________________________________________________________ 9 To configure a module enter the number associated with it followed by cr For detailed configuration of each module refer to DS71 or DS71 MD2 page 26 DS74 page 51 DS73 page 53 RPC page 64 ...
Страница 18: ...t may have occurred in shipment If there is damage to the equipment or if materials are missing contact BayTech customer service at 228 467 8231 or call toll free inside the United States at 800 523 2702 At a minimum you should receive the following a The DS RPC Unit b This manual with any applicable addendum s c 1 ea 9FRJ45PC4 adapter d 1 ea RJ08X007 RJ45 crossed modular cable e 1 ea RJ 11 telco ...
Страница 19: ...nges CAUTION High voltage surges and spikes can damage this equipment To protect from such power surges and spikes this unit must have a good earth ground A grounding screw connection is located near the power switch on the back of the unit CAUTION Before removing or replacing any modules turn off main power switch located on the DS RPC unit Communication to the DS RPC will be disrupted while powe...
Страница 20: ...le if Outlet 1 and Outlet 2 are ON and power is removed from the DS RPC the status of Outlet 1 and Outlet 2 will return to ON when power is restored to the DS RPC POWER UP SEQUENCE In order to minimize power surges the DS RPC sequences power to each outlet in the ON state in 0 3 second intervals When power is applied to the DS RPC the initialization sequence requires a delay of 10 seconds before p...
Страница 21: ...nector Bay Tech Part No 9FRJ45PC 4 An adapter to convert from a DB 25 connector to an RJ 45 connector is also available from Bay Tech upon request Bay Tech Part No 25FRJ45PC 4 The 8 pin crossed modular cable is configured to operate with these adapters CAUTION All power should be removed from the DS RPC prior to removing or installing cables Figures 1 and 2 provide visual representation of an RJ 4...
Страница 22: ...e receiving of characters 2 Gnd Signal ground 3 Handshake Out RTS Line Driver Inactive State High 12 V when power is applied Not used to enable disable 4 TX Out Transmit Data data out 5 RX In Receive Data data in 6 Handshake In DSR Handshake In 12V when not used 7 Gnd or DCD In Signal ground when Jumper JP6 2 is connected to JP6 3 In order for the DS71 to take advantage of DCD Logon Logoff and Aut...
Страница 23: ...TS Line Driver Inactive State Low 12V when port is not selected unless programmed differently 4 TX Out Transmit Data data out 5 RX In Receive Data data in 6 Handshake In DSR Handshake In 12V when not used 7 Gnd Signal ground 8 Handshake In CTS Used as a handshake line to enable disable the receiving of characters Table 3 DS74 PIN SIGNAL DEFINITION The DS74 module has four RJ 45 ports for connectin...
Страница 24: ...g to telephone lines You may connect either RJ 11 port to a Telco wall jack using a standard RJ 11 straight through cable These ports are in parallel and the second port is available for another telco device Connect an external modemto the EIA 232 serial port on the DS71 host module by using the 25MRJ45MD 6 adapter and RJ08X007 8 bit crossed modular cable supplied with this unit Fig 3 MD 6 MODEM S...
Страница 25: ...terface the DS RPC to another BayTech product with modular connectors such as the RPC Remote Power Control Unit 1 2 3 4 5 6 7 8 8 7 6 5 4 3 2 PIN RJ 45 RJ 45 CONDUCTOR BLUE ORANGE BLACK RED GREEN YELLOW BROWN GRAY PIN 1 GRAY BROWN YELLOW GREEN RED BLACK ORANGE BLUE COLOR COLOR Fig 4 Crossed 8 pin Modular Cable BayTech Part No RJ08X007 Fig 5 DE 9 PC Serial Port Adapter BayTech Part No 9FRJ45PC4 ...
Страница 26: ... computer terminal or external modem Most serial computers do not have RJ 45 connections therefore an adapter is provided with this unit to convert from a DE 9 connector to an RJ 45 connector BayTech Part No 9FRJ45PC 4 If you are connecting to a modem use a modem adapter BayTech Part No 25MRJ45MD 6 and an RJ08X007 8 pin crossed modular cable BayTech also manufactures a computer terminal adapter Ba...
Страница 27: ...guration mode or connected to a DS74 I O port when a modem connection is established the serial port user will be booted off allowing the remote user to communicate with the DS RPC Using the RJ04X007 RJ 11 modular cable connect either port labeled LINE on the DS71 MD2 module to the telco wall jack Using communications software dial the modem using the ATDT command NOTE Both LINE ports are active a...
Страница 28: ...__________________ 20 10BASE T NETWORK Using a straight 10Base T cable connect the PORT CONNECTION RJ 45 port labeled ETHERNET on the DS73TP module to an RJ 45 port on the network hub The LINK link integrity LED located on the front panel of the DS73TP illuminates when a good connection is established between the DS73TP and the hub ...
Страница 29: ...ID DS71 Port Select Code BT Attention Character Device A 2 1 1 Device B 2 2 2 Device C 2 3 3 Device D 2 4 4 DS RPC 3 1 5 Configure C I O Modules Reset RM Unit Reset RU Exit X Logout T Enter Request NOTE The DS71 and DS71 MD2 have some menus which are different Where this situation occurs it will be addressed Or this menu if the DS71 MD2 is used Data Switch Series F 0 13 Bay Technical Associates Un...
Страница 30: ... Configure C I O Modules Reset RM Unit Reset RU Exit X Logout T Enter Request NOTE Depending on the DS RPC model the menus may vary according to the number of DS74 modules installed in the unit If this is not an initial set up and Password has already been enabled you are prompted to login After logging in successfully invoke the main menu by sending the attention character five times NOTE Passwor...
Страница 31: ... located on a peripheral module port send the port select code default is BT the module number a comma and then the port number followed by cr there are no spaces in the string For example to select port 4 located on module 2 type BT2 4 cr To select port 1 on module 9 DS9 model type BT9 1 cr To disconnect type BT cr then the attention character To configure a module type BT and the module number f...
Страница 32: ...ta transmission However before a connection can be made to another port the binary mode must be terminated Place the port in binary mode by sending the port select code a capital B and a carriage return BTB For example if using the default Port Select Code BT place Module 2 Port 1 in binary mode by typing BT2 1 cr BTB cr Terminate Binary From the terminal emulation software send Mode a BREAK condi...
Страница 33: ...ter Device A 2 1 1 Device B 2 2 2 Device C 2 3 3 Device D 2 4 4 DS73 3 1 5 Configure C I O Modules Reset RM Unit Reset RU Exit X Logout T Enter Request From the host module main menu select the DS73TP module connected to the network or exit from the main menu and send the ASCII character string to select the DS73TP module The DS73TP sends the following header and prompts for user name DS73TP Ether...
Страница 34: ...n menu then select the module to configure To select Module 1 type BT1 cr The DS71 or DS71 MD2 responds Requested Connection Made Send the ASCII configuration command CONFIG The configuration menu appears Enter the number of the module to configure followed by cr To configure the host module 1 select 1 The following configuration menu appears for the DS71 Copyright C Bay Technical Associates 1998 ...
Страница 35: ...ard 6 Connect Port ID Echo 7 Login Setup 8 Local Modem Setup 9 Unit ID U Configure Another Module C Exit X Enter Request NOTE The DS71 uses the DCD Logon Logoff function in line item 9 The DS71 MD2 uses the Local Modem Setup function in line item 9 STATUS View the status of most user programmable features by selecting 1 Status from the configuration menu followed by cr User programmable features i...
Страница 36: ...ol Disabled Modem Connectivity is 60 minutes Escape Character is 43 Login Setup Header is Enabled Password is Disabled Menu is Enabled Auto Connect Port is Module 2 Port 1 Auto Connect is Disabled Strike Any Key to Continue Port Device Name Baud Rate Word Size Stop Bits Parity Xon Xmit Xoff Recv Line DTR Drive RTS 1 Host EIA 232 9600 8 1 None Off Off High High 2 Host Modem 57 6k 8 1 None Off Off H...
Страница 37: ... 1 EIA 232 9600 8 1 None Off Off High High Exit Save 1 Set Parity 5 Set Baud Rate 2 Set Xon Xoff 6 Set Word Size 3 RTS Line Driver 7 Set Stop Bits 4 DTR Line Driver 8 Enter Request Select the corresponding number to configure baud rate word size stop bits parity NOTE DTR is unchangeable when configuring the serial port For example to change the baud rate to 115 2K select 2 Set Baud Rate followed b...
Страница 38: ... selecting 3 Set Word Size The DS71 displays the following list of available word sizes 1 For 5 2 For 6 3 For 7 4 For 8 Enter the corresponding number for the desired word size The DS71 responds with the new configuration status Module 1 Serial Port Configuration Port Device Name Baud Rate Word Size Stop Bits Parity Xon Xmit Xoff Recv Line DTR Drive RTS 1 EIA 232 115 2K 8 1 None Off Off High High ...
Страница 39: ...made necessary changes to the host device type Y for yes followed by cr New configuration changes are stored permanently in non volatile memory DS71 MD2 From the configuration menu select 2 Serial Port Configuration followed by cr The DS unit asks for the Host Device number Enter Host Device Number 1 2 Selecting 1 will give the same results as the DS71 in the previous section Selecting 2 will give...
Страница 40: ...he DS71 MD2 displays the following list of available baud rates 1 for 300 2 for 600 3 for 1200 4 for 2400 5 for 4800 6 for 9600 7 for 19200 8 for 38400 9 for 57 6K A for 76 8K B for 115 2K Enter Request Type B for 115 2K baud rate The DS71 MD2 responds with the new configuration status Module 1 Serial Port Configuration Port Device Name Baud Rate Word Size Stop Bits Parity Xon Xmit Xoff Recv Line ...
Страница 41: ...ity 5 Set Baud Rate 2 Set Xon Xoff 6 Set Word Size 3 RTS Line Driver 7 Set Stop Bits 4 DTR Line Driver 8 Enter Request To permanently save configuration changes select 1 Exit Save from the selection menu followed by cr The DS71 MD2 responds Change Host Device to Match NEW Configuration Before Answering this Request Save Changes Permanently Y N IMPORTANT This message reminds you to change the seria...
Страница 42: ... port or device connected to the port you are configuring The DS71 has one host device and the DS71 MD2 has two host devices The default name for the host device in Port 1 is EIA 232 The default name for Port 2 MD2 only is Host MODEM Select 3 Port Device Name followed by cr The DS71 MD2 module responds Enter Host Device Number 1 2 Select the number of the host device whose Port Device Name you wan...
Страница 43: ...ax 16 characters or ENTER for no change If you are satisfied with the new device name press cr The DS71 MD2 responds again Enter Host Device Number 1 2 If there are no further changes press cr to return to the configuration menu The DS71 goes directly to the configuration menu PORT SELECT The Port Select Code is an ASCII character CODE string sent by the host terminal to the DS71 or DS71 MD2 modul...
Страница 44: ...Select Code is BAYTECH Change It Y N If there are no additional changes type N for no followed by cr The DS71 or DS71 MD2 module stores the new port select code permanently in non volatile memory and returns to the configuration menu ATTENTION The Attention Character is a character used CHARACTER in sequence to invoke the main menu Default Attention Character is a semicolon From the configuration ...
Страница 45: ... Character Method GUARD it is possible for the same character being sent as data from another device to be interpreted by the host module as the attention character This could result in unwanted port disconnection If enabled the Disconnect Time Guard feature provides reliable binary data transmission by providing a one second timeguard after the host module receives the attention character If more...
Страница 46: ...mber and port number you are connected to Choose the port device name or the module and port number to echo when a DS71 or DS71 MD2 module selects a port on a the DS74 module Default Connect Port ID Echo is disabled From the configuration menu select 7 Connect Port ID Echo followed by cr The DS71 or DS71 MD2 module presents the current status of Port ID Echo and asks if you want to change Port ID ...
Страница 47: ...for the selected DS74 is used LOGIN SETUP This configures how the host modem responds upon login You can Enable Disable the Header and Menu and or Enable Disable Program Password and Auto Connect Port From the configuration menu select 8 Login Setup followed by cr The following menu appears Header 1 Password 2 Menu 3 Auto Connect 4 Exit X CR Header If enabled the following header appears with the ...
Страница 48: ...nt to enable Header status Type N for no followed by cr if you want to disable Header Enter cr for no change Password To change Password or Enable Disable Password upon login select 2 Password from the selection menu followed by cr Default Password is BTA disabled The DS71 or DS71 MD2 module responds Change Password 1 Enable Disable 2 Exit X CR To change the current password select 1 Change Passwo...
Страница 49: ...hange Enter Y for yes followed by cr if you want to enable Password Type N for no followed by cr if you want to disable Password Enter cr no change Menu Enable Disable Menu upon login Default menu is enabled If disabled the following header appears upon login without the main menu Data Switch Series F 2 01 Bay Technical Associates Unit ID DS71 MD2 Port Select Code BT Attention Character NOTE This ...
Страница 50: ...er Request Select 3 Menu from the selection menu followed by cr The DS71 or DS71 MD2 module displays the current menu status and asks if you want to enable Menu is Disabled Enable Y N CR for no change Type Y for yes followed by cr if you want to enable Menu Type N for no followed by cr if you want to disable Menu Type cr for no change NOTE If Auto Connect Port is enabled Header and Menu are automa...
Страница 51: ...ection menu followed by cr The following Auto Connect Port menu appears Auto Connect Port is Module 2 Port 1 Auto Connect is Enabled Change Auto Connect Port 1 Enabled Disabled 2 Exit X CR Enter Request The DS71 series module displays the current auto connect port and its current status To change the auto connect port module number and port number select 1 Change Auto Connect Port followed by cr T...
Страница 52: ...Port configuration in non volatile memory and returns to the Auto Connect Port menu DCD LOGON LOGOFF When enabled DCD Logon Logoff prevents DS71 only unwanted modem connections by requiring login before a modem connection is established DCD high If a disconnection occurs DCD low the DS RPC will logoff If another connection is established DCD high login will be required before resuming normal opera...
Страница 53: ...no followed by cr Type cr for no change LOCAL MODEM SETUP The DS71 MD2 has an internal 14 4K bps DS71 MD2 ONLY modem Programmable modem characteristics include number of rings to answer modem to modem Xon Xoff handshaking amount of inactivity before the modem automatically disconnects connectivity time out and the escape character used to tell the modem the information you are sending is a command...
Страница 54: ...if you want to change Rings to Auto Answer 2 Change It Y N Type Y for yes followed by cr The DS71 MD2 responds Enter Number of Rings to Auto Answer 1 to 4 Enter the number of times you want the modem to ring before it answers followed by cr The DS71 MD2 stores the change in non volatile memory and returns to the Local Modem Setup menu Modem to Modem to Modem Xon Xoff is an ASCII Modem Xon or Xoff ...
Страница 55: ... of 0 disables Connectivity Timeout The timer starts when the modem answers DCD high The modem will disconnect regardless of activity when time runs out Default Connectivity Timeout is 60 minutes Select 3 Connectivity Timeout from the Local Modem Setup menu followed by cr The DS71 MD2 displays the current setting and asks if you want to change Modem Connectivity Time out is 60 minutes Change It Y ...
Страница 56: ...character eliminates this problem Default Escape Character is 43 which is 2B Hex or a plus sign Select 4 Escape Character from the Local Modem Setup menu followed by cr The DS71 MD2 displays the current Escape Character and asks if you want to change Escape Character is 43 Change It Y N Type Y for yes followed by cr The DS71 MD2 responds Enter Decimal Value for Escape Character 0 to 127 or press E...
Страница 57: ... by cr The DS71 or DS71 MD2 module responds Enter Unit ID 64 chars max Enter the desired Unit ID followed by cr The DS71 or DS71 MD2 stores the changes in non volatile memory and returns to the configuration menu I O MODULES RESET From the main menu type RM to select I O Modules Reset followed by cr The DS71 or DS71 MD2 module recycles power to all I O ports on all peripheral modules and responds ...
Страница 58: ...Unit followed by cr The DS71 Selection series module resets the unit and responds Reset Unit Allow approximately 10 seconds for the unit to reset ASCII To reset the DS Series Unit using the ASCII Character character string method send the following String command BTRESET cr NOTE If you are locally connected through the serial port when the unit is reset the DS71 or DS71 MD2 module sends the header...
Страница 59: ...ect the module to configure To select Module 2 type BT2 cr The DS RPC responds Requested Connection Made Send the ASCII configuration command CONFIG The above configuration menu appears Select the module number that corresponds to the DS74 module you want to configure The following configuration menu appears Copyright C Bay Technical Associates 1998 DS71 Data Switch Series EIA 232 I O Module Modul...
Страница 60: ...______________________________________________________ 52 SERIAL PORT Selections 1 8 are fully programmable in the CONFIGURATION DS74 module Select the parameter to change make the change then save to non volatile memory PORT DEVICE NAME This parameter works as previously described in this manual ...
Страница 61: ...sing the DS73TP module via the DS71 or DS71 MD2 module and a PPP Dial Up session IMPORTANT For network access you must configure the Module and Dial up IP addresses Subnet Mask and Gateway Address The module must be reset for network changes to take effect From the main menu select C Configuration followed by cr or exit from the main menu and send the ASCII character string BTCONFIG cr The followi...
Страница 62: ...ive Module IP Address 200 4 3 72 Dial up IP Address 200 4 3 73 Subnet Mask 255 255 255 0 Gateway Addr 200 4 3 1 Primary DNS 0 0 0 0 Secondary DNS 0 0 0 0 Primary NBNS 0 0 0 0 Secondary NBNS 0 0 0 0 Ethernet Addr 00 C0 48 1A 24 5D Network Cable Connections good Module IP Address 1 Dial in IP Address 2 Subnet Mask 3 Gateway 4 Primary DNS 5 Secondary DNS 6 Primary NBNS 7 Secondary NBNS 8 User Name 9 ...
Страница 63: ...e IP Address in dotted decimal form the DS73TP responds again Enter Module IP address in dotted decimal form The DS73TP responds indefinitely with the same request until the Module IP Address in entered in the correct form IMPORTANT The Module IP Address and the Dial Up Address must be different in order for the DS73TP to function correctly NOTE There should be no active connections while configur...
Страница 64: ...ss in dotted decimal form The DS73TP responds indefinitely with the same request until the Dial Up IP Address in entered in the correct form Subnet Mask The Subnet Mask is a bit mask that identifies the network portion of the IP address allowing the DS73TP to determine whether to send a packet directly to the client or to a gate way The Subnet Mask consist of four bytes each byte ranging from 0 to...
Страница 65: ...dress consists of four bytes each byte ranging from 0 to 255 From the configuration menu select 4 Gateway followed by cr The DS73TP responds Enter Gateway address in dotted decimal form Enter the Gatewayaddress Example 200 4 5 50 followed by cr The DS73TP resumes the configuration menu Default Gateway address is 0 0 0 0 If you fail to enter the Gateway address in dotted decimal form the DS73TP res...
Страница 66: ...again Enter Primary DNS address in dotted decimal form The DS73TP responds indefinitely with the same request until the Primary DNS address is entered in the correct form Secondary From the configuration menu select 6 DNS Secondary DNS Domain Name Server followed by cr The DS73TP responds Enter Secondary DNS address in dotted decimal form Enter the Secondary DNS address Example 200 4 5 54 followed...
Страница 67: ... 55 followed by cr The DS73TP resumes the configuration menu Default Primary NBNS address is 0 0 0 0 If you fail to enter the Primary NBNS address in dotted decimal form the DS73TP responds again Enter Primary NBNS address in dotted decimal form The DS73TP responds indefinitely with the same request until the Primary NBNS address is entered in the correct form Secondary From the configuration menu...
Страница 68: ...tion menu Select 9 User Name followed by cr The DS73TP module responds with the current user name and asks if you want to change Default User Name is user1 Current User Name user1 Enter User Name 8 chars max If desired enter a new user name 8 chars max The DS73TP stores the change in non volatile memory and resumes the configuration menu NOTE User Name is Case Sensitive Password If enabled passwor...
Страница 69: ... is Case Sensitive Module The Module Name is reported by the Name module for identification purposes when a connection is established From the configuration menu select 11 Module Name followed by cr The DS73TP module responds with the current module name and asks if you want to change Default Module Name is DS73TP Current Module Name DS73TP Enter Module Name 8 chars max If desired enter a new modu...
Страница 70: ...r and REBOOT n cr where n represents the outlet number and cr represents a carriage return There are four red LEDs on the front of the RPC unit There is a corresponding red LED for each of the RPC s four receptacles If any or all of the LEDs are illuminated corresponding receptacle s are turned ON and consequently attached equipment is receiving power If any or all of the LEDs are not illuminated ...
Страница 71: ...wing commands ON n OFF n REBOOT n where n is the outlet number you want to command Entering an outlet number of 0 sends the command to all outlets Example To turn On Outlet 3 type ON 3 from the DS RPC prompt RPC The RPC responds Turn On Outlet 3 Y N Responding Y for yes turns On Outlet 3 Observe the status of Outlet 3 has changed to On in the status menu DS RPC Power Control c 1997 by BayTech Rev ...
Страница 72: ...S RPC configuration menu allows the user to 1 set or change a password 2 customize the outlet name s to identify equipment attached to the RPC 3 enable or disable confirmation 4 enable or disable status menu The password is disabled from the factory by making the password a carriage return If a password other than a carriage return is set the DS RPC requires password entry before allowing the user...
Страница 73: ... enter the password incorrectly the DS RPC responds with an Error message and returns to the main menu Consequently you must start over by typing CONFIG to access the configuration menu If you enter the current password correctly the DS RPC responds Enter New Password Enter a new password maximum field length 8 alphanumeric characters followed by cr The DS RPC responds Re Enter New Password Re ent...
Страница 74: ... disables password protection Change Outlet Name Select 2 Change Outlet Name and press cr The DS RPC sends the following menu 1 OUTLET 1 2 OUTLET 2 3 OUTLET 3 4 OUTLET 4 Enter Request Enter the number of the outlet you want to change If you want to change the name of Outlet 4 type the number 4 at the Enter Request prompt followed by cr The DS RPC responds Enter Enter a new receptacle name maximum ...
Страница 75: ...to confirm the command For example if the command ON 3 is sent and the enable disable confirmation is enabled the DS RPC responds Turn On Outlet 3 Y N If the enable disable feature is disabled the DS RPC will not ask to confirm the command From the configuration menu select 3 Enable Disable Confirmation Depending on the current status of the switch the DS RPC responds with the option to change the...
Страница 76: ... __________________________________________________________________________________________ 68 Circuit Breaker On 1 Outlet 1 Off 2 Outlet 2 Off 3 Outlet 3 Off 4 Outlet 4 Off RPC If the Enable Disable Status Menu feature is disabled only the RPC prompt appears ...
Страница 77: ...ion available to help the applications engineers answer your questions efficiently Use the next page to record vital information a The DS RPC model type and what modules you are using b The unit and module serial numbers c The host device and peripherals you have connected to the DS RPC d Provide a general description of the application you are using and what you are trying to accomplish e What ca...
Страница 78: ...NUMBER SERIAL NUMBER USE USE OUTLET 1 OUTLET 2 MODEL MODEL SERIAL NUMBER SERIAL NUMBER USE USE OUTLET3 OUTLET 4 MODEL MODEL SERIAL NUMBER SERIAL NUMBER USE USE Type of adapters _____________________________________________ ____________________________________________________________ Type of cables _______________________________________________ _____________________________________________________...
Страница 79: ... for repair warranty work or upgrade follow the instructions below for repackaging and shipping INSTRUCTIONS FOR REPACKAGING AND SHIPPING a Call BayTech to get a Return Authorization Number IMPORTANT Without this number BayTech will not accept returns b Use the original packaging if available or choose a heavy cardboard box c Surround your unit with a minimum of two inches of insulation d Be sure ...
Страница 80: ...e user will be responsible for the expense of correcting the interference FCC REQUIREMENTS FOR THE DS71 MD2 a Federal Communications Commission FCC has established rules permitting a direct connection to the telephone network These connections use standardized jacks Do not use this equipment on party lines or coin lines b If this device is malfunctioning it may also be causing harm to the telephon...
Страница 81: ...number REN is used to determine how many devices can be connected to you telephone line In most areas the sum of the RENs of all devices on a single line should not exceed five If there are too many devices attached they may not ring properly In case of equipment malfunction BayTech should perform all repairs It is the responsibility of the user requiring service to report the need for service to ...
Страница 82: ... connector RJ 45 Environment 0 to 70 C 5 to 95 humidity 0 to 70 C 5 to 95 humidity 0 to 70 C 5 to 95 humidity 0 to 70 C 5 to 95 humidity 0 to 70 C 5 to 95 humidity Dimensions DS2 RPC 16 3 4 w x 7 1 8 d x 1 3 4 h DS4 RPC 16 3 4 w x 7 1 8 d x 2 5 8 h N A N A N A N A Weight 6 lbs and 7 lbs N A N A N A N A Power Receptacles 4 each 115 VAC 60 Hz 15 Amp N A N A N A N A Circuit Breaker 125 VAC 15 Amp N A...
Страница 83: ...table Xon Xoff TD RD CD MR CX CTS DTR selectable Xon Xoff CTS DTR selectable Xon Xoff N A Baud Rate N A 300 600 1200 2400 4800 9600 19 2K 38 4K 57 6K 76 8K or 115 2K 300 600 1200 2400 4800 9600 19 2K 38 4K 57 6K 76 8K or 115 2K and 14 4k internal modem 300 600 1200 2400 4800 9600 19 2K 38 4K 57 6K 76 8K or 115 2K N A Word Size N A 5 6 7 or 8 bits N A 5 6 7 or 8 bits N A Stop Bits N A 1 1 1 2 or 2 ...
Страница 84: ...ON AT B1 Fixed Serial Port Rate default AT C1 Normal CD Operations default AT D2 Normal DTR Operations default ATS0 1 Auto answer telephone line in 4 or fewer rings ATE0 Modem does not display keyboard commands ATQ1 Place modem into quiet mode AT W0 Save the modem s configuration in non volatile memory NOTE To send all of the above at the same time type the following command AT B1 C1 D2S0 1E0Q1 W0...
Страница 85: ...ETATION ATS23 59 Fixed Serial Port Rate default AT C1 Normal CD Operations default AT D2 Normal DTR Operations default ATS0 1 Auto answer telephone line in 4 or fewer rings ATE0 Modem does not display keyboard commands ATQ1 Place modem into quiet mode AT W0 Save modem s configuration in non volatile memory NOTE To send all of the above at the same time type the following command ATS23 59 C1 D2S0 1...
Страница 86: ...u are dialing from as well as the network server must have modems installed IMPORTANT You must have dial up networking installed on your computer MY COMPUTER Ø From the icon menu double click the My Computer icon Ø Double click the Dial Up Networking icon MAKE NEW CONNECTION Ø Double click the Make New Connection icon Ø At Type a name for the computer you are dialing enter a name For example DS RP...
Страница 87: ...compression Ø In the Allowed Network Protocols Enable TCP IP Ø Click TCP IP Settings Enable the following settings You must enable Header Compression Server Assigned IP Address Server Assigned Name Server Address Use IP Header Compression User default gateway on remote network Ø Click OK three times Ø You should be in the Dial Up Networking screen Ø Select the device you are adding The icon for th...
Страница 88: ...he DS73TP module to auto connect at dial up If not auto connected you must select the port from the DS71 or DS71 MD2 module main menu If you are auto connected and decide not to enter the module type the attention character five times to return to the DS71 or DS71 MD2 module main menu Ø After a successful connection is established select the DS73TP module The following menu appears Ø DS73TP Ethern...
Страница 89: ...DS RPC OWNER S MANUAL APPENDIX D __________________________________________________________________________________________ 81 APPENDIX D DRAWINGS DS71 MECHANICAL LAYOUT ...
Страница 90: ...DS RPC OWNER S MANUAL APPENDIX D __________________________________________________________________________________________ 82 DS71 MD2 MECHANICAL LAYOUT ...
Страница 91: ...DS RPC OWNER S MANUAL APPENDIX D __________________________________________________________________________________________ 83 DS74 MECHANICAL LAYOUT ...
Страница 92: ...DS RPC OWNER S MANUAL APPENDIX D __________________________________________________________________________________________ 84 DS73 MECHANICAL LAYOUT ...
Страница 93: ...leases the module to receive the attention character BTm Calls up a module where m is a module number BTm p Calls up a module and port where m is a module number and p is a port number BTB Locks the module in the binary mode A Break signal must be sent to clear this lock CONFIG Accesses the module configuration menu BTRESET Resets the unit All communication will be lost if attached via the modem ...
Страница 94: ...ort ID Echo 27 38 39 Connectivity Timeout 45 47 Copyright ii 25 27 51 54 80 Crossed Cable 17 Current Password 7 22 65 D Data acquisition and control 2 DCD High 44 46 47 DCD Logon Logoff 27 44 45 DCD Low 44 Default 7 22 55 56 57 58 59 64 67 76 77 Devices 13 15 Disconnect TimeGuard 27 37 Domain Name Server DNS 54 58 59 E EIA 232port 2 EIA 232 Port 74 EIA 232 Serial Connection 6 Emulation 69 Escape C...
Страница 95: ...ty 2 6 19 28 29 31 52 Password 7 22 28 39 40 41 54 60 61 64 65 66 79 80 Password Protection 66 Port Device Name 27 34 35 39 51 52 Port Select Code 6 7 21 23 24 25 27 28 35 36 39 41 42 Port selection 2 Power 11 12 62 64 Power On Off State 12 Power Up Sequence 12 PPP Dial Up Connection 25 26 Q Quick Start 6 R Reboot 12 62 64 Repackaging 71 Reset 49 64 Returning 71 Rings to Answer 45 46 RTS DTR Line ...
Страница 96: ..._____________________________________________________________________ 88 User Programmable 27 34 35 Users Manual iii W Windows Dial Up Tutorial 25 78 Word size 2 Word Size 29 30 31 32 33 52 75 X Xon Xoff 19 28 29 30 31 32 33 45 46 47 52 75 XON XOFF 2 ...